Fix nr_phy_test printed metrics

Some tables displayed the min value twice instead of min and max.
This commit is contained in:
dvdgrgrtt 2021-10-26 17:00:13 +02:00 committed by dvdgrgrtt
parent 7227f03314
commit 7a64406773
1 changed files with 2 additions and 2 deletions

View File

@ -265,7 +265,7 @@ int main(int argc, char** argv)
"EPRE (dB)",
metrics.gnb_stack.pucch.epre_db_avg,
metrics.gnb_stack.pucch.epre_db_min,
metrics.gnb_stack.pucch.epre_db_min);
metrics.gnb_stack.pucch.epre_db_max);
srsran::console(" | %10s | %+10.2f | %+10.2f | %+10.2f |\n",
"RSRP (dB)",
metrics.gnb_stack.pucch.rsrp_db_avg,
@ -332,7 +332,7 @@ int main(int argc, char** argv)
"EPRE (dB)",
metrics.gnb_stack.pusch.epre_db_avg,
metrics.gnb_stack.pusch.epre_db_min,
metrics.gnb_stack.pusch.epre_db_min);
metrics.gnb_stack.pusch.epre_db_max);
srsran::console(" | %10s | %+10.2f | %+10.2f | %+10.2f |\n",
"RSRP (dB)",
metrics.gnb_stack.pusch.rsrp_db_avg,