Vars held in the settings dict (gv.sd) from controller values (cvalues): en:1 enabled (operation) rd:0 rain delay (hours) mm:0 manual mode (bool) rbt:0 reboot (bool) from options: htp:8080 http port the program will run on (o12) seq:1 sequential/concurrent operation (o16) sdt:0 station delay time(o17) mton:0 master on delay (o19) mtoff:0 master off delay (020) nbrd:1 number of boards (o15) tz:16 time zone (o1) urs:0 use rain sensor (o21 - not used) rst:1 Rain sensor type (normaly open =1, dafault, or closed, o22 - not used) wl:100 water level (percent, o23) mas:0 master station index (o18) ipas:1 ignore passwprd (bool, o25) pwd:"b3BlbmRvb3I=" encoded password (default shown here) loc:"" location (for weather - not used) rdst:0 rain delay stop time (unix time stamp) rs:0 rain sensed (o22) nopts:13 Number of optiions to be displayed for scheduling: bsy:0 program buisy mnp:32 maximum number of programs nprogs:0 number of programs (can be calculated form length of prog array) mo:[0] master operation bytes - contains bits per board for stations with master set ir:[0] ignore rain bytes - contains bits per board for stations to ignore rain delay and rain sensor rsn:0 Reset all stations nst:8 number of stations for logging: lg:0 log runs if = "checked" lr:100 limit number of log records to keep, 0 = no limit