Fix for TS reset before EEPROM is written after calibration
This commit is contained in:
parent
983e365dd7
commit
4113df387c
10
comms.ino
10
comms.ino
|
@ -777,7 +777,7 @@ This function is used to store calibration data sent by Tuner Studio.
|
|||
void receiveCalibration(byte tableID)
|
||||
{
|
||||
byte* pnt_TargetTable; //Pointer that will be used to point to the required target table
|
||||
int OFFSET, DIVISION_FACTOR, BYTES_PER_VALUE;
|
||||
int OFFSET, DIVISION_FACTOR, BYTES_PER_VALUE, EEPROM_START;
|
||||
|
||||
switch (tableID)
|
||||
{
|
||||
|
@ -787,6 +787,7 @@ void receiveCalibration(byte tableID)
|
|||
OFFSET = CALIBRATION_TEMPERATURE_OFFSET; //
|
||||
DIVISION_FACTOR = 10;
|
||||
BYTES_PER_VALUE = 2;
|
||||
EEPROM_START = EEPROM_CALIBRATION_CLT;
|
||||
break;
|
||||
case 1:
|
||||
//Inlet air temp table
|
||||
|
@ -794,6 +795,7 @@ void receiveCalibration(byte tableID)
|
|||
OFFSET = CALIBRATION_TEMPERATURE_OFFSET;
|
||||
DIVISION_FACTOR = 10;
|
||||
BYTES_PER_VALUE = 2;
|
||||
EEPROM_START = EEPROM_CALIBRATION_IAT;
|
||||
break;
|
||||
case 2:
|
||||
//O2 table
|
||||
|
@ -801,6 +803,7 @@ void receiveCalibration(byte tableID)
|
|||
OFFSET = 0;
|
||||
DIVISION_FACTOR = 1;
|
||||
BYTES_PER_VALUE = 1;
|
||||
EEPROM_START = EEPROM_CALIBRATION_O2;
|
||||
break;
|
||||
|
||||
default:
|
||||
|
@ -848,7 +851,10 @@ void receiveCalibration(byte tableID)
|
|||
}
|
||||
|
||||
pnt_TargetTable[(x / 2)] = (byte)tempValue;
|
||||
int y = EEPROM_CALIBRATION_O2 + counter;
|
||||
|
||||
//From TS3.x onwards, the EEPROM must be written here as TS restarts immediately after the process completes which is before the EEPROM write completes
|
||||
int y = EEPROM_START + (x / 2);
|
||||
EEPROM.update(y, (byte)tempValue);
|
||||
|
||||
every2nd = false;
|
||||
analogWrite(13, (counter % 50) );
|
||||
|
|
Loading…