Only allow O2 sensor readings when they sensor type is not disabled
This commit is contained in:
parent
e524e8636a
commit
c18b29b7d2
|
@ -1286,7 +1286,7 @@ menuDialog = main
|
|||
menu = "Tools"
|
||||
subMenu = mapCal, "Calibrate Pressure Sensors"
|
||||
subMenu = std_ms2gentherm, "Calibrate Temperature Sensors", 0
|
||||
subMenu = std_ms2geno2, "Calibrate AFR Sensor", 0
|
||||
subMenu = std_ms2geno2, "Calibrate AFR Sensor", { egoType > 0 }
|
||||
subMenu = sensorFilters, "Set analog sensor filters"
|
||||
|
||||
menuDialog = main
|
||||
|
@ -1714,6 +1714,7 @@ menuDialog = main
|
|||
dialog = egoControl, ""
|
||||
topicHelp = "http://speeduino.com/wiki/index.php/AFR/O2"
|
||||
field = "Sensor Type", egoType
|
||||
field = "#Please ensure you calibrate your O2 sensor in the Tools menu", { egoType }
|
||||
field = "Algorithm", egoAlgorithm, { egoType }
|
||||
field = "Ignition Events per Step", egoCount, { egoType && (egoAlgorithm < 3) }
|
||||
field = "Controller Auth +/-", egoLimit, { egoType && (egoAlgorithm < 3) }
|
||||
|
|
|
@ -360,15 +360,25 @@ void readBaro()
|
|||
|
||||
void readO2()
|
||||
{
|
||||
unsigned int tempReading;
|
||||
#if defined(ANALOG_ISR)
|
||||
tempReading = fastMap1023toX(AnChannel[pinO2-A0], 511); //Get the current O2 value.
|
||||
#else
|
||||
tempReading = analogRead(pinO2);
|
||||
tempReading = fastMap1023toX(analogRead(pinO2), 511); //Get the current O2 value.
|
||||
#endif
|
||||
currentStatus.O2ADC = ADC_FILTER(tempReading, configPage4.ADCFILTER_O2, currentStatus.O2ADC);
|
||||
currentStatus.O2 = o2CalibrationTable[currentStatus.O2ADC];
|
||||
//An O2 read is only performed if an O2 sensor type is selected. This is to prevent potentially dangerous use of the O2 readings prior to proper setup/calibration
|
||||
if(configPage6.egoType > 0)
|
||||
{
|
||||
unsigned int tempReading;
|
||||
#if defined(ANALOG_ISR)
|
||||
tempReading = fastMap1023toX(AnChannel[pinO2-A0], 511); //Get the current O2 value.
|
||||
#else
|
||||
tempReading = analogRead(pinO2);
|
||||
tempReading = fastMap1023toX(analogRead(pinO2), 511); //Get the current O2 value.
|
||||
#endif
|
||||
currentStatus.O2ADC = ADC_FILTER(tempReading, configPage4.ADCFILTER_O2, currentStatus.O2ADC);
|
||||
currentStatus.O2 = o2CalibrationTable[currentStatus.O2ADC];
|
||||
}
|
||||
else
|
||||
{
|
||||
currentStatus.O2ADC = 0;
|
||||
currentStatus.O2 = 0;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
void readO2_2()
|
||||
|
|