rusefi/firmware/controllers/system_fsio.h

80 lines
3.1 KiB
C

// this https://en.wikipedia.org/wiki/Reverse_Polish_notation is generated automatically
// from controllers/system_fsio.txt
// on 2021-03-20_12_45_43_719
//
//
// in this file we define system FSIO expressions
//
// system_fsio.txt is input for compile_fsio_file tool, see gen_system_fsio.bat
//
// see http://rusefi.com/wiki/index.php?title=Manual:Flexible_Logic
//
// Jan 19, 2017
// Andrey Belomutskiy, (c) 2012-2017
//
// different way to have the same result would be using "self"
// (self and (coolant > fan_off_setting)) | (coolant > fan_on_setting) | is_clt_broken
// Human-readable: ((time_since_boot >= 0) & (time_since_boot < startup_fuel_pump_duration)) | (time_since_trigger < 1)
#define FUEL_PUMP_LOGIC "time_since_boot 0 >= time_since_boot startup_fuel_pump_duration < & time_since_trigger 1 < |"
// Human-readable: coolant > 120
#define TOO_HOT_LOGIC "coolant 120 >"
// Combined RPM, CLT and VBATT warning light
// Human-readable: (rpm > fsio_setting(2)) | ((coolant > fsio_setting(3)) | (vbatt < fsio_setting(4)))
#define COMBINED_WARNING_LIGHT "rpm 2 fsio_setting > coolant 3 fsio_setting > vbatt 4 fsio_setting < | |"
//needed by EFI_MAIN_RELAY_CONTROL which is currently FALSE for most of the boards
// todo: make '5' a setting?
// todo: always have 'EFI_MAIN_RELAY_CONTROL'?
// at the moment microRusEFI would not be happy with vbatt > 5 since microRusEFI senses main relay output
// todo https://github.com/rusefi/rusefi/issues/2258
//MAIN_RELAY_LOGIC=(time_since_boot >= 0 & time_since_boot < 2) | (vbatt > 5) | in_shutdown
//MAIN_RELAY_LOGIC=(!in_mr_bench) & ((vbatt > 5) | in_shutdown)
// Human-readable: (!in_mr_bench) & (vbatt > 5)
#define MAIN_RELAY_LOGIC "in_mr_bench ! vbatt 5 > &"
// could be used for simple variable intake geometry setups or warning light or starter block
// Human-readable: rpm > fsio_setting(1)
#define RPM_ABOVE_USER_SETTING_1 "rpm 1 fsio_setting >"
// Human-readable: rpm < fsio_setting(3)
#define RPM_BELOW_USER_SETTING_3 "rpm 3 fsio_setting <"
// could be used for simple variable intake geometry setups or warning light or starter block
// Human-readable: rpm > fsio_setting(1)
#define RPM_ABOVE_USER_SETTING_1 "rpm 1 fsio_setting >"
// Human-readable: rpm > fsio_setting(2)
#define RPM_ABOVE_USER_SETTING_2 "rpm 2 fsio_setting >"
// Human-readable: rpm > 5500
#define RPM_ABOVE_5500_ON_OFF "rpm 5500 >"
// Human-readable: rpm > 6000
#define RPM_ABOVE_6000_ON_OFF "rpm 6000 >"
// Human-readable: (rpm > 1000) * 0.7
#define RPM_ABOVE_1000_SOLENOID_70_DUTY "rpm 1000 > 0.7 *"
// Human-readable: (rpm > 2000) * 0.5
#define RPM_ABOVE_2000_SOLENOID_50_DUTY "rpm 2000 > 0.5 *"
// Human-readable: (rpm > 6000) * 0.8
#define RPM_ABOVE_6000_SOLENOID_80_DUTY "rpm 6000 > 0.8 *"
// Human-readable: rpm < fsio_setting(1)
#define RPM_BELOW_USER_SETTING_1 "rpm 1 fsio_setting <"
// starter block using configurable parameter
// Human-readable: rpm < cranking_rpm
#define STARTER_RELAY_LOGIC "rpm cranking_rpm <"
// Human-readable: fsio_table (3, rpm, map) / 100
#define BOOST_CONTROLLER "3 rpm map fsio_table 100 /"
// Human-readable: if(fsio_analog_input (0) > 20, 0, 10)
#define ANALOG_CONDITION "0 fsio_analog_input 20 > 0 10 if"