fome-fw/firmware/config/engines/nissan_vq.lua

114 lines
2.8 KiB
Lua
Raw Normal View History

2022-11-15 06:04:23 -08:00
// by definition this should be a copy-paste of https://github.com/rusefi/rusefi/blob/master/firmware/controllers/lua/examples/350z-ac.txt
strncpy(config->luaScript, R"(
2022-11-23 20:45:25 -08:00
IN_284 = 0x284 -- 644
IN_285 = 0x285
IN_35D = 0x35d
2022-11-15 06:04:23 -08:00
2022-11-17 21:59:47 -08:00
OUT_1F9 = 0x1F9 -- 505
OUT_233 = 0x233 -- 563
OUT_23D = 0x23D -- 573
OUT_23E = 0x23E -- 574
2022-11-15 06:04:23 -08:00
setTickRate(100)
t = Timer.new()
t : reset()
globalAcOut = 0
2022-11-23 20:45:25 -08:00
function getTwoBytesMSB(data, offset, factor)
return (data[offset + 1] * 256 + data[offset + 2]) * factor
end
2022-11-15 06:04:23 -08:00
function onTick()
2022-11-17 21:59:47 -08:00
local MAF = getSensor("MAF")
MAF = (MAF == nil and 0 or MAF)
local TPS = getSensor("Tps1")
TPS = (TPS == nil and 0 or TPS)
local PPS = getSensor("AcceleratorPedal")
PPS = (PPS == nil and 0 or PPS)
-- print ("MAF " .. MAF .. " TPS " .. TPS .. " PPS " .. PPS)
2022-11-15 06:04:23 -08:00
local rpmValue = math.floor(getSensor("RPM") + 0.5)
local RPMread = rpmValue / 3.15
local RPMhi = RPMread / 256
local RPMlo = RPMread
cltValue = getSensor("CLT")
cltValue = (cltValue == nil and 0 or cltValue)
--print('ac out = ' ..globalAcOut)
if globalAcOut == 1 and rpmValue > 250 then
fanPayloadOff = { 0x88, 0x00 }
fanPayloadLo = { 0x88, 0x00 }
fanPayloadHi = { 0x88, 0x00 }
else
--print('ac off payload')
fanPayloadOff = { 0x00, 0x00 }
fanPayloadLo = { 0x40, 0x00 }
fanPayloadHi = { 0x80, 0x00 }
end
cltGauge = 0x00
-- clt gauge stuff
if cltValue < 115 then
cltGauge = math.floor(cltValue * 1.5 + 0.5)
else
cltGauge = 0xF0
end
-- print('clt gauge = '..cltGauge)
-- rpm fun stuff
2022-11-17 21:59:47 -08:00
PPS256 = PPS * 256 / 100
TPScapped = (TPS > 0.5 and 0.5 or TPS)
2022-11-15 06:04:23 -08:00
if t : getElapsedSeconds() < 2 then
2022-11-17 21:59:47 -08:00
CLTandRPM_D = { 0x00, PPS256, 0x0C, 0x01, 0x0A, 0x87, 0xFF, 0xFF }
2022-11-15 06:04:23 -08:00
else
2022-11-17 21:59:47 -08:00
CLTandRPM_D = { 0x00, PPS256, 0x0c, RPMlo, RPMhi, 0x87, 0xFF, cltGauge }
2022-11-15 06:04:23 -08:00
end
state_233 = rpmValue > 250 and 0x10 or 0x18
CLTandRPM_3 = { cltGauge, 0x8C, 0x20, state_233, RPMlo, 0x00, 0x00, RPMhi }
txCan(1, OUT_233, 0, CLTandRPM_3) -- transmit CLT and RPM for who knows whom
txCan(1, OUT_23D, 0, CLTandRPM_D) -- transmit CLT and RPM for gauge cluster
if rpmValue > 250 then
if cltValue <= 80 then
txCan(1, OUT_1F9, 0, fanPayloadOff)
elseif cltValue < 85 then
-- send nothing
elseif cltValue < 90 then
txCan(1, OUT_1F9, 0, fanPayloadLo)
else
txCan(1, OUT_1F9, 0, fanPayloadHi)
end
else
txCan(1, OUT_1F9, 0, fanPayloadOff)
end
-- print('CLT temp' ..cltValue)
end
2022-11-23 20:45:25 -08:00
function onCanRxAbs1(bus, id, dlc, data)
kph = getTwoBytesMSB(data, 0, 0.005)
end
2022-11-15 06:04:23 -08:00
2022-11-23 20:45:25 -08:00
function onCanRxAc(bus, id, dlc, data)
2022-11-15 06:04:23 -08:00
--print('got CAN id=' ..id ..' dlc=' ..dlc)
--print('ac value is= '..data[1])
if data[1] == 193 then
setAcRequestState(true)
globalAcOut = 1
--print('ac is on')
else
setAcRequestState(false)
globalAcOut = 0
--print('ac is off')
end
end
2022-11-23 20:45:25 -08:00
canRxAdd(IN_35D, onCanRxAbs1)
canRxAdd(IN_35D, onCanRxAc)
2022-11-15 06:04:23 -08:00
)", efi::size(config->luaScript));