Auto-generated configs and docs

This commit is contained in:
GitHub gen-configs Action 2024-03-25 05:50:58 +00:00
parent ebe78cbb4b
commit 797f1dbaf1
32 changed files with 95 additions and 94 deletions

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.alphax-2chan.701277070"
signature = "rusEFI (FOME) master.2024.03.25.alphax-2chan.2582027027"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.alphax-2chan.701277070" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.alphax-2chan.2582027027" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.alphax-4chan.2734989807"
signature = "rusEFI (FOME) master.2024.03.25.alphax-4chan.321821042"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.alphax-4chan.2734989807" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.alphax-4chan.321821042" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.alphax-8chan.3686770454"
signature = "rusEFI (FOME) master.2024.03.25.alphax-8chan.1804967819"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.alphax-8chan.3686770454" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.alphax-8chan.1804967819" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.atlas.1543321769"
signature = "rusEFI (FOME) master.2024.03.25.atlas.3956736052"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.atlas.1543321769" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.atlas.3956736052" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.core48.332246076"
signature = "rusEFI (FOME) master.2024.03.25.core48.2749863073"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.core48.332246076" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.core48.2749863073" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.core8.884255231"
signature = "rusEFI (FOME) master.2024.03.25.core8.2224984418"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.core8.884255231" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.core8.2224984418" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.f407-discovery.3990693161"
signature = "rusEFI (FOME) master.2024.03.25.f407-discovery.1576476084"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.f407-discovery.3990693161" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.f407-discovery.1576476084" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.f429-discovery.211002441"
signature = "rusEFI (FOME) master.2024.03.25.f429-discovery.3166280916"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.f429-discovery.211002441" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.f429-discovery.3166280916" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.frankenso_na6.784417923"
signature = "rusEFI (FOME) master.2024.03.25.frankenso_na6.2666232862"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.frankenso_na6.784417923" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.frankenso_na6.2666232862" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.harley81.2231802931"
signature = "rusEFI (FOME) master.2024.03.25.harley81.892118190"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.harley81.2231802931" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.harley81.892118190" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen-gm-e67.1710918298"
signature = "rusEFI (FOME) master.2024.03.25.hellen-gm-e67.3587224071"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen-gm-e67.1710918298" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen-gm-e67.3587224071" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen-honda-k.4268442843"
signature = "rusEFI (FOME) master.2024.03.25.hellen-honda-k.1312914502"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen-honda-k.4268442843" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen-honda-k.1312914502" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen-nb1.4222924277"
signature = "rusEFI (FOME) master.2024.03.25.hellen-nb1.1268682088"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen-nb1.4222924277" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen-nb1.1268682088" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen121nissan.2339314111"
signature = "rusEFI (FOME) master.2024.03.25.hellen121nissan.994386210"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen121nissan.2339314111" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen121nissan.994386210" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen121vag.661395052"
signature = "rusEFI (FOME) master.2024.03.25.hellen121vag.2537959153"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen121vag.661395052" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen121vag.2537959153" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen128.2348926446"
signature = "rusEFI (FOME) master.2024.03.25.hellen128.1009515891"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen128.2348926446" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen128.1009515891" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen154hyundai.418833679"
signature = "rusEFI (FOME) master.2024.03.25.hellen154hyundai.2833046930"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen154hyundai.418833679" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen154hyundai.2833046930" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen72.4247207422"
signature = "rusEFI (FOME) master.2024.03.25.hellen72.1292698979"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen72.4247207422" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen72.1292698979" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen81.1370310524"
signature = "rusEFI (FOME) master.2024.03.25.hellen81.3783753697"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen81.1370310524" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen81.3783753697" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellen88bmw.1469403215"
signature = "rusEFI (FOME) master.2024.03.25.hellen88bmw.3888081106"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellen88bmw.1469403215" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellen88bmw.3888081106" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellenNA6.522446286"
signature = "rusEFI (FOME) master.2024.03.25.hellenNA6.2936659283"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellenNA6.522446286" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellenNA6.2936659283" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.hellenNA8_96.2743571070"
signature = "rusEFI (FOME) master.2024.03.25.hellenNA8_96.330148579"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.hellenNA8_96.2743571070" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.hellenNA8_96.330148579" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.mre_f4.3944595953"
signature = "rusEFI (FOME) master.2024.03.25.mre_f4.1530394988"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.mre_f4.3944595953" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.mre_f4.1530394988" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.mre_f7.3944595953"
signature = "rusEFI (FOME) master.2024.03.25.mre_f7.1530394988"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.mre_f7.3944595953" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.mre_f7.1530394988" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.prometheus_405.1007118809"
signature = "rusEFI (FOME) master.2024.03.25.prometheus_405.2351780164"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.prometheus_405.1007118809" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.prometheus_405.2351780164" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.prometheus_469.1007118809"
signature = "rusEFI (FOME) master.2024.03.25.prometheus_469.2351780164"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.prometheus_469.1007118809" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.prometheus_469.2351780164" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.proteus_f4.1453929884"
signature = "rusEFI (FOME) master.2024.03.25.proteus_f4.3867348225"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.proteus_f4.1453929884" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.proteus_f4.3867348225" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.proteus_f7.1453929884"
signature = "rusEFI (FOME) master.2024.03.25.proteus_f7.3867348225"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.proteus_f7.1453929884" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.proteus_f7.3867348225" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.proteus_h7.1453929884"
signature = "rusEFI (FOME) master.2024.03.25.proteus_h7.3867348225"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.proteus_h7.1453929884" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.proteus_h7.3867348225" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.small-can-board.3841962967"
signature = "rusEFI (FOME) master.2024.03.25.small-can-board.1423280970"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.small-can-board.3841962967" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.small-can-board.1423280970" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -2,7 +2,7 @@
;
; This file has been generated by invoking gen_config.bat.
; The input files are
; rusefi.input the common template
; tunerstudio.template.ini the common template
; rusefi_config.txt the project specific file
;
; In TunerStudio some fields have little question mark on the left of the name for additional field tips.
@ -33,12 +33,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI (FOME) master.2024.03.23.tdg-pdm8.2252179563"
signature = "rusEFI (FOME) master.2024.03.25.tdg-pdm8.907522294"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI (FOME) master.2024.03.23.tdg-pdm8.2252179563" ; signature is expected to be 7 or more characters.
signature= "rusEFI (FOME) master.2024.03.25.tdg-pdm8.907522294" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false

View File

@ -972,6 +972,7 @@ public class Fields {
public static final int SentEtbType_FORD_TYPE_1 = 2;
public static final int SentEtbType_GM_TYPE_1 = 1;
public static final int SentEtbType_NONE = 0;
public static final int SIGNATURE_HASH = 1576476084;
public static final int spi_device_e_SPI_DEVICE_1 = 1;
public static final int spi_device_e_SPI_DEVICE_2 = 2;
public static final int spi_device_e_SPI_DEVICE_3 = 3;
@ -1178,7 +1179,7 @@ public class Fields {
public static final int TS_RESPONSE_UNDERRUN = 0x80;
public static final int TS_RESPONSE_UNRECOGNIZED_COMMAND = 0x83;
public static final char TS_SET_LOGGER_SWITCH = 'l';
public static final String TS_SIGNATURE = "rusEFI (FOME) master.2024.03.23.f407-discovery.3990693161";
public static final String TS_SIGNATURE = "rusEFI (FOME) master.2024.03.25.f407-discovery.1576476084";
public static final char TS_SINGLE_WRITE_COMMAND = 'W';
public static final char TS_TEST_COMMAND = 't';
public static final int TS_TOTAL_OUTPUT_SIZE = 1384;