preparation for industrial-PID

This commit is contained in:
rusefi 2019-10-23 21:41:30 -04:00
parent 0fcf3bfa4e
commit bc750f61cf
2 changed files with 11 additions and 3 deletions

View File

@ -832,7 +832,9 @@ custom pin_mode_e 1 bits, U08, @OFFSET@, [0:6], @@pin_mode_e_enum@@
pid_s alternatorControl;
pid_s etb;
float fuelRailPressure;; "kPa", 1, 0.0, 0, 1000.0, 2
uint8_t[16] unusedFormerWarmupAfrPid;
float alternator_derivativeFilterLoss;; "x", 1, 0.0, -1000000, 1000000, 4
float alternator_antiwindupFreq;; "x", 1, 0.0, -1000000, 1000000, 4
uint8_t[8] unusedFormerWarmupAfrPid;
! todo: mapErrorDetectionIdleTooLow? 30kPa is usually lowest on idle
float mapErrorDetectionTooLow;kPa value which is too low to be true;"kPa", 1, 0, -100.0, 100.0, 2

View File

@ -1,6 +1,6 @@
package com.rusefi.config.generated;
// this file was generated automatically by rusEfi tool ConfigDefinition.jar based on integration\rusefi_config.txt Sun Sep 29 11:56:14 EDT 2019
// this file was generated automatically by rusEfi tool ConfigDefinition.jar based on integration\rusefi_config.txt Wed Oct 23 21:40:23 EDT 2019
// by class com.rusefi.output.FileJavaFieldsConsumer
import com.rusefi.config.*;
@ -40,6 +40,8 @@ public class Fields {
public static final int afterCrankingIACtaperDuration_offset = 2036;
public static final int alFIn_offset = 4024;
public static final int alignEngineSnifferAtTDC_offset = 744;
public static final int alternator_antiwindupFreq_offset = 1764;
public static final int alternator_derivativeFilterLoss_offset = 1760;
public static final int alternatorControl_dFactor_offset = 1724;
public static final int alternatorControl_iFactor_offset = 1720;
public static final int alternatorControl_maxValue_offset = 1734;
@ -1244,7 +1246,7 @@ public class Fields {
public static final int unusedBit31_offset = 1464;
public static final int unusedErrorPin_offset = 2040;
public static final int unusedFlexFuelSensor_offset = 3100;
public static final int unusedFormerWarmupAfrPid_offset = 1760;
public static final int unusedFormerWarmupAfrPid_offset = 1768;
public static final int unusedMa2_offset = 711;
public static final int unusedOldWarmupAfr_offset = 744;
public static final int unusedSpiPadding2_offset = 806;
@ -1844,6 +1846,8 @@ public class Fields {
public static final Field ETB_MINVALUE = Field.create("ETB_MINVALUE", 1752, FieldType.INT16);
public static final Field ETB_MAXVALUE = Field.create("ETB_MAXVALUE", 1754, FieldType.INT16);
public static final Field FUELRAILPRESSURE = Field.create("FUELRAILPRESSURE", 1756, FieldType.FLOAT);
public static final Field ALTERNATOR_DERIVATIVEFILTERLOSS = Field.create("ALTERNATOR_DERIVATIVEFILTERLOSS", 1760, FieldType.FLOAT);
public static final Field ALTERNATOR_ANTIWINDUPFREQ = Field.create("ALTERNATOR_ANTIWINDUPFREQ", 1764, FieldType.FLOAT);
public static final Field MAPERRORDETECTIONTOOLOW = Field.create("MAPERRORDETECTIONTOOLOW", 1776, FieldType.FLOAT);
public static final Field MAPERRORDETECTIONTOOHIGH = Field.create("MAPERRORDETECTIONTOOHIGH", 1780, FieldType.FLOAT);
public static final Field STEP1RPMWINDOW = Field.create("STEP1RPMWINDOW", 1784, FieldType.INT);
@ -2636,6 +2640,8 @@ public class Fields {
ETB_MINVALUE,
ETB_MAXVALUE,
FUELRAILPRESSURE,
ALTERNATOR_DERIVATIVEFILTERLOSS,
ALTERNATOR_ANTIWINDUPFREQ,
MAPERRORDETECTIONTOOLOW,
MAPERRORDETECTIONTOOHIGH,
STEP1RPMWINDOW,