add `A/C Pressure Enable Hysteresis` setting #6804

This commit is contained in:
kifir 2024-08-20 22:40:53 +03:00 committed by rusefillc
parent 62eaa151cc
commit 0211e671f9
2 changed files with 15 additions and 14 deletions

View File

@ -1589,7 +1589,7 @@ uint8_t alsEtbPosition;;"", 1, 0, 0, 20000, 0
int ALSIdleAdd;;"%", 1, 0, 0, 100, 2 int ALSIdleAdd;;"%", 1, 0, 0, 100, 2
int ALSEtbAdd;;"%", 1, 0, 0, 100, 2 int ALSEtbAdd;;"%", 1, 0, 0, 100, 2
float ALSSkipRatio;;"", 1, 0, 0, 1, 1 float ALSSkipRatio;;"", 1, 0, 0, 1, 1
uint8_t unusedSorry11 uint8_t autoscale acPressureEnableHyst;Hysterisis: if Pressure High Disable is 240kpa, and acPressureEnableHyst is 20, when the ECU sees 240kpa, A/C will be disabled, and stay disabled until 240-20=220kpa is reached;"kPa (absolute)", 0.5, 0, 0, 125, 1
pin_input_mode_e ALSActivatePinMode; pin_input_mode_e ALSActivatePinMode;
uint8_t autoscale tpsSecondaryMaximum;For Ford TPS, use 53%. For Toyota ETCS-i, use ~65%;"%", 0.5, 0, 0, 100, 1 uint8_t autoscale tpsSecondaryMaximum;For Ford TPS, use 53%. For Toyota ETCS-i, use ~65%;"%", 0.5, 0, 0, 100, 1

View File

@ -3817,6 +3817,7 @@ cmd_set_engine_type_default = "@@TS_IO_TEST_COMMAND_char@@@@ts_command_e_TS_
field = "RPM low threshold", acLowRpmLimit field = "RPM low threshold", acLowRpmLimit
field = "Pressure Low disable", minAcPressure field = "Pressure Low disable", minAcPressure
field = "Pressure High disable", maxAcPressure field = "Pressure High disable", maxAcPressure
field = "A/C Pressure Enable Hysteresis", acPressureEnableHyst
dialog = acSettings, "", border dialog = acSettings, "", border
panel = acSettingsWest, West panel = acSettingsWest, West