Auto-generated configs and docs
This commit is contained in:
parent
9321aae600
commit
74ea14b29e
|
@ -1027,7 +1027,7 @@
|
|||
#define SENT_INPUT_COUNT 1
|
||||
#define show_Frankenso_presets true
|
||||
#define show_test_presets true
|
||||
#define SIGNATURE_HASH snap_40623
|
||||
#define SIGNATURE_HASH snap_7609
|
||||
#define specs_s_size 12
|
||||
#define spi_device_e_auto_enum 0="SPI_NONE",1="SPI_DEVICE_1",2="SPI_DEVICE_2",3="SPI_DEVICE_3",4="SPI_DEVICE_4"
|
||||
#define spi_device_e_SPI_DEVICE_1 1
|
||||
|
@ -1301,12 +1301,12 @@
|
|||
#define ts_show_vbatt true
|
||||
#define ts_show_vr_threshold_2 true
|
||||
#define ts_show_vr_threshold_all true
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.cypress.snap_40623"
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.cypress.snap_7609"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
#define TS_TEST_COMMAND_char t
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1260
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1264
|
||||
#define TsCalMode_EtbKd 5
|
||||
#define TsCalMode_EtbKi 4
|
||||
#define TsCalMode_EtbKp 3
|
||||
|
|
|
@ -1027,7 +1027,7 @@
|
|||
#define SENT_INPUT_COUNT 1
|
||||
#define show_Frankenso_presets true
|
||||
#define show_test_presets true
|
||||
#define SIGNATURE_HASH snap_15459
|
||||
#define SIGNATURE_HASH snap_49013
|
||||
#define specs_s_size 12
|
||||
#define spi_device_e_auto_enum 0="SPI_NONE",1="SPI_DEVICE_1",2="SPI_DEVICE_2",3="SPI_DEVICE_3",4="SPI_DEVICE_4"
|
||||
#define spi_device_e_SPI_DEVICE_1 1
|
||||
|
@ -1301,12 +1301,12 @@
|
|||
#define ts_show_vbatt true
|
||||
#define ts_show_vr_threshold_2 true
|
||||
#define ts_show_vr_threshold_all true
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.kin.snap_15459"
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.kin.snap_49013"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
#define TS_TEST_COMMAND_char t
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1260
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1264
|
||||
#define TsCalMode_EtbKd 5
|
||||
#define TsCalMode_EtbKi 4
|
||||
#define TsCalMode_EtbKp 3
|
||||
|
|
|
@ -993,7 +993,7 @@
|
|||
#define show_Frankenso_presets false
|
||||
#define show_Proteus_presets false
|
||||
#define show_test_presets false
|
||||
#define SIGNATURE_HASH snap_18293
|
||||
#define SIGNATURE_HASH snap_50275
|
||||
#define specs_s_size 12
|
||||
#define spi_device_e_auto_enum 0="SPI_NONE",1="SPI_DEVICE_1",2="SPI_DEVICE_2",3="SPI_DEVICE_3",4="SPI_DEVICE_4"
|
||||
#define spi_device_e_SPI_DEVICE_1 1
|
||||
|
@ -1268,12 +1268,12 @@
|
|||
#define ts_show_vbatt true
|
||||
#define ts_show_vr_threshold_2 true
|
||||
#define ts_show_vr_threshold_all true
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.subaru_eg33_f7.snap_18293"
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.subaru_eg33_f7.snap_50275"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
#define TS_TEST_COMMAND_char t
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1260
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1264
|
||||
#define TsCalMode_EtbKd 5
|
||||
#define TsCalMode_EtbKi 4
|
||||
#define TsCalMode_EtbKp 3
|
||||
|
|
|
@ -491,6 +491,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
|
|
@ -313,6 +313,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -677,11 +677,12 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
|
|
@ -482,11 +482,12 @@ etbFeedForward("etbFeedForward", SensorCategory.SENSOR_INPUTS, FieldType.INT, 12
|
|||
etbIntegralError("etbIntegralError", SensorCategory.SENSOR_INPUTS, FieldType.INT, 1232, 1.0, -10000.0, 10000.0, ""),
|
||||
etbCurrentTarget("etbCurrentTarget", SensorCategory.SENSOR_INPUTS, FieldType.INT, 1236, 1.0, -10000.0, 10000.0, "%"),
|
||||
etbCurrentAdjustedTarget("etbCurrentAdjustedTarget", SensorCategory.SENSOR_INPUTS, FieldType.INT, 1240, 1.0, -10000.0, 10000.0, "%"),
|
||||
faultCode("faultCode", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1248, 1.0, -1.0, -1.0, ""),
|
||||
heaterDuty("heaterDuty", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1249, 1.0, 0.0, 100.0, "%"),
|
||||
pumpDuty("pumpDuty", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1250, 1.0, 0.0, 100.0, "%"),
|
||||
alignmentFill_at_3("need 4 byte alignment", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1251, 1.0, -20.0, 100.0, "units"),
|
||||
tempC("tempC", SensorCategory.SENSOR_INPUTS, FieldType.INT16, 1252, 1.0, 500.0, 1000.0, "C"),
|
||||
nernstVoltage("nernstVoltage", SensorCategory.SENSOR_INPUTS, FieldType.INT16, 1254, 0.001, 0.0, 1.0, "V"),
|
||||
esr("esr", SensorCategory.SENSOR_INPUTS, FieldType.INT16, 1256, 1.0, -1.0, -1.0, ""),
|
||||
alignmentFill_at_10("need 4 byte alignment", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1258, 1.0, -20.0, 100.0, "units"),
|
||||
etbDutyRateOfChange("etbDutyRateOfChange", SensorCategory.SENSOR_INPUTS, FieldType.INT, 1248, 1.0, -1.0, -1.0, ""),
|
||||
faultCode("faultCode", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1252, 1.0, -1.0, -1.0, ""),
|
||||
heaterDuty("heaterDuty", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1253, 1.0, 0.0, 100.0, "%"),
|
||||
pumpDuty("pumpDuty", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1254, 1.0, 0.0, 100.0, "%"),
|
||||
alignmentFill_at_3("need 4 byte alignment", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1255, 1.0, -20.0, 100.0, "units"),
|
||||
tempC("tempC", SensorCategory.SENSOR_INPUTS, FieldType.INT16, 1256, 1.0, 500.0, 1000.0, "C"),
|
||||
nernstVoltage("nernstVoltage", SensorCategory.SENSOR_INPUTS, FieldType.INT16, 1258, 0.001, 0.0, 1.0, "V"),
|
||||
esr("esr", SensorCategory.SENSOR_INPUTS, FieldType.INT16, 1260, 1.0, -1.0, -1.0, ""),
|
||||
alignmentFill_at_10("need 4 byte alignment", SensorCategory.SENSOR_INPUTS, FieldType.INT8, 1262, 1.0, -20.0, 100.0, "units"),
|
||||
|
|
|
@ -1,2 +1,2 @@
|
|||
// generated by gen_live_documentation.sh / LiveDataProcessor.java
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1260
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1264
|
|
@ -1,4 +1,4 @@
|
|||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/actuators/electronic_throttle.txt Wed Nov 23 01:41:35 UTC 2022
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/actuators/electronic_throttle.txt Sun Nov 27 23:27:34 UTC 2022
|
||||
// by class com.rusefi.output.CHeaderConsumer
|
||||
// begin
|
||||
#pragma once
|
||||
|
@ -134,8 +134,12 @@ struct electronic_throttle_s {
|
|||
/**
|
||||
offset 28 bit 31 */
|
||||
bool unusedBit_8_31 : 1 {};
|
||||
/**
|
||||
* offset 32
|
||||
*/
|
||||
float etbDutyRateOfChange = (float)0;
|
||||
};
|
||||
static_assert(sizeof(electronic_throttle_s) == 32);
|
||||
static_assert(sizeof(electronic_throttle_s) == 36);
|
||||
|
||||
// end
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/actuators/electronic_throttle.txt Wed Nov 23 01:41:35 UTC 2022
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/actuators/electronic_throttle.txt Sun Nov 27 23:27:34 UTC 2022
|
||||
|
|
|
@ -1027,7 +1027,7 @@
|
|||
#define SENT_INPUT_COUNT 1
|
||||
#define show_Frankenso_presets true
|
||||
#define show_test_presets true
|
||||
#define SIGNATURE_HASH snap_40623
|
||||
#define SIGNATURE_HASH snap_7609
|
||||
#define specs_s_size 12
|
||||
#define spi_device_e_auto_enum 0="SPI_NONE",1="SPI_DEVICE_1",2="SPI_DEVICE_2",3="SPI_DEVICE_3",4="SPI_DEVICE_4"
|
||||
#define spi_device_e_SPI_DEVICE_1 1
|
||||
|
@ -1301,12 +1301,12 @@
|
|||
#define ts_show_vbatt true
|
||||
#define ts_show_vr_threshold_2 true
|
||||
#define ts_show_vr_threshold_all true
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.all.snap_40623"
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.all.snap_7609"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
#define TS_TEST_COMMAND_char t
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1260
|
||||
#define TS_TOTAL_OUTPUT_SIZE 1264
|
||||
#define TsCalMode_EtbKd 5
|
||||
#define TsCalMode_EtbKi 4
|
||||
#define TsCalMode_EtbKp 3
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_38624
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.48way.snap_38624"
|
||||
#define SIGNATURE_HASH snap_5622
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.48way.snap_5622"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_40623
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.all.snap_40623"
|
||||
#define SIGNATURE_HASH snap_7609
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.all.snap_7609"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_963
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.alphax-2chan.snap_963"
|
||||
#define SIGNATURE_HASH snap_32981
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.alphax-2chan.snap_32981"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_23840
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.alphax-4chan.snap_23840"
|
||||
#define SIGNATURE_HASH snap_56886
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.alphax-4chan.snap_56886"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_27528
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.atlas.snap_27528"
|
||||
#define SIGNATURE_HASH snap_59550
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.atlas.snap_59550"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_53078
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.core8.snap_53078"
|
||||
#define SIGNATURE_HASH snap_19520
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.core8.snap_19520"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_40623
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.cypress.snap_40623"
|
||||
#define SIGNATURE_HASH snap_7609
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.cypress.snap_7609"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_40623
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.f407-discovery.snap_40623"
|
||||
#define SIGNATURE_HASH snap_7609
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.f407-discovery.snap_7609"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_40623
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.f429-discovery.snap_40623"
|
||||
#define SIGNATURE_HASH snap_7609
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.f429-discovery.snap_7609"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_25195
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.frankenso_na6.snap_25195"
|
||||
#define SIGNATURE_HASH snap_57725
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.frankenso_na6.snap_57725"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_55376
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.harley81.snap_55376"
|
||||
#define SIGNATURE_HASH snap_23366
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.harley81.snap_23366"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_64939
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen-gm-e67.snap_64939"
|
||||
#define SIGNATURE_HASH snap_32445
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen-gm-e67.snap_32445"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_44899
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen-nb1.snap_44899"
|
||||
#define SIGNATURE_HASH snap_11381
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen-nb1.snap_11381"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_37843
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen121nissan.snap_37843"
|
||||
#define SIGNATURE_HASH snap_4293
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen121nissan.snap_4293"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_2482
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen121vag.snap_2482"
|
||||
#define SIGNATURE_HASH snap_35492
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen121vag.snap_35492"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_58260
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen128.snap_58260"
|
||||
#define SIGNATURE_HASH snap_24706
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen128.snap_24706"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_42060
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen154hyundai.snap_42060"
|
||||
#define SIGNATURE_HASH snap_10074
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen154hyundai.snap_10074"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_36900
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen72.snap_36900"
|
||||
#define SIGNATURE_HASH snap_4914
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen72.snap_4914"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_18085
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen81.snap_18085"
|
||||
#define SIGNATURE_HASH snap_50611
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen81.snap_50611"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_36195
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen88bmw.snap_36195"
|
||||
#define SIGNATURE_HASH snap_3701
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellen88bmw.snap_3701"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_12184
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellenNA6.snap_12184"
|
||||
#define SIGNATURE_HASH snap_44174
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellenNA6.snap_44174"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_12103
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellenNA8_96.snap_12103"
|
||||
#define SIGNATURE_HASH snap_44113
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.hellenNA8_96.snap_44113"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_15459
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.kin.snap_15459"
|
||||
#define SIGNATURE_HASH snap_49013
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.kin.snap_49013"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_63919
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.mre_f4.snap_63919"
|
||||
#define SIGNATURE_HASH snap_31417
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.mre_f4.snap_31417"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_63919
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.mre_f7.snap_63919"
|
||||
#define SIGNATURE_HASH snap_31417
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.mre_f7.snap_31417"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_18249
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.prometheus_405.snap_18249"
|
||||
#define SIGNATURE_HASH snap_50271
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.prometheus_405.snap_50271"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_18249
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.prometheus_469.snap_18249"
|
||||
#define SIGNATURE_HASH snap_50271
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.prometheus_469.snap_50271"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_23001
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.proteus_f4.snap_23001"
|
||||
#define SIGNATURE_HASH snap_56015
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.proteus_f4.snap_56015"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_23001
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.proteus_f7.snap_23001"
|
||||
#define SIGNATURE_HASH snap_56015
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.proteus_f7.snap_56015"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_23001
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.proteus_h7.snap_23001"
|
||||
#define SIGNATURE_HASH snap_56015
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.proteus_h7.snap_56015"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_subaru_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_18293
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.subaru_eg33_f7.snap_18293"
|
||||
#define SIGNATURE_HASH snap_50275
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.subaru_eg33_f7.snap_50275"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh by SignatureConsumer
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH snap_20731
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.tdg-pdm8.snap_20731"
|
||||
#define SIGNATURE_HASH snap_54253
|
||||
#define TS_SIGNATURE "rusEFI 2022.11.27.tdg-pdm8.snap_54253"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.all.snap_40623"
|
||||
signature = "rusEFI 2022.11.27.all.snap_7609"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.all.snap_40623" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.all.snap_7609" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:48 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:23 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.48way.snap_38624"
|
||||
signature = "rusEFI 2022.11.27.48way.snap_5622"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.48way.snap_38624" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.48way.snap_5622" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:35 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:06 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5488,6 +5491,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.alphax-2chan.snap_963"
|
||||
signature = "rusEFI 2022.11.27.alphax-2chan.snap_32981"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.alphax-2chan.snap_963" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.alphax-2chan.snap_32981" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:15 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:39 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5484,6 +5487,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.alphax-4chan.snap_23840"
|
||||
signature = "rusEFI 2022.11.27.alphax-4chan.snap_56886"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.alphax-4chan.snap_23840" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.alphax-4chan.snap_56886" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:16 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:41 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.atlas.snap_27528"
|
||||
signature = "rusEFI 2022.11.27.atlas.snap_59550"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.atlas.snap_27528" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.atlas.snap_59550" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:46 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:20 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.core8.snap_53078"
|
||||
signature = "rusEFI 2022.11.27.core8.snap_19520"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.core8.snap_53078" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.core8.snap_19520" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:34 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:04 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5488,6 +5491,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.cypress.snap_40623"
|
||||
signature = "rusEFI 2022.11.27.cypress.snap_7609"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.cypress.snap_40623" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.cypress.snap_7609" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 27 14:13:13 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 27 23:27:36 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.f407-discovery.snap_40623"
|
||||
signature = "rusEFI 2022.11.27.f407-discovery.snap_7609"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.f407-discovery.snap_40623" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.f407-discovery.snap_7609" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:43 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:17 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.f429-discovery.snap_40623"
|
||||
signature = "rusEFI 2022.11.27.f429-discovery.snap_7609"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.f429-discovery.snap_40623" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.f429-discovery.snap_7609" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:45 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:18 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.frankenso_na6.snap_25195"
|
||||
signature = "rusEFI 2022.11.27.frankenso_na6.snap_57725"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.frankenso_na6.snap_25195" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.frankenso_na6.snap_57725" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:36 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:08 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.harley81.snap_55376"
|
||||
signature = "rusEFI 2022.11.27.harley81.snap_23366"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.harley81.snap_55376" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.harley81.snap_23366" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:17 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:42 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen-gm-e67.snap_64939"
|
||||
signature = "rusEFI 2022.11.27.hellen-gm-e67.snap_32445"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen-gm-e67.snap_64939" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen-gm-e67.snap_32445" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:28 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:56 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen-nb1.snap_44899"
|
||||
signature = "rusEFI 2022.11.27.hellen-nb1.snap_11381"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen-nb1.snap_44899" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen-nb1.snap_11381" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:27 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:55 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen121nissan.snap_37843"
|
||||
signature = "rusEFI 2022.11.27.hellen121nissan.snap_4293"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen121nissan.snap_37843" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen121nissan.snap_4293" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:21 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:47 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen121vag.snap_2482"
|
||||
signature = "rusEFI 2022.11.27.hellen121vag.snap_35492"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen121vag.snap_2482" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen121vag.snap_35492" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:20 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:45 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen128.snap_58260"
|
||||
signature = "rusEFI 2022.11.27.hellen128.snap_24706"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen128.snap_58260" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen128.snap_24706" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:18 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:44 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen154hyundai.snap_42060"
|
||||
signature = "rusEFI 2022.11.27.hellen154hyundai.snap_10074"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen154hyundai.snap_42060" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen154hyundai.snap_10074" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:22 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:48 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen72.snap_36900"
|
||||
signature = "rusEFI 2022.11.27.hellen72.snap_4914"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen72.snap_36900" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen72.snap_4914" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:24 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:52 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen81.snap_18085"
|
||||
signature = "rusEFI 2022.11.27.hellen81.snap_50611"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen81.snap_18085" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen81.snap_50611" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:25 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:53 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5485,6 +5488,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellen88bmw.snap_36195"
|
||||
signature = "rusEFI 2022.11.27.hellen88bmw.snap_3701"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellen88bmw.snap_36195" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellen88bmw.snap_3701" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:23 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:50 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellenNA6.snap_12184"
|
||||
signature = "rusEFI 2022.11.27.hellenNA6.snap_44174"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellenNA6.snap_12184" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellenNA6.snap_44174" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:29 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:58 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.hellenNA8_96.snap_12103"
|
||||
signature = "rusEFI 2022.11.27.hellenNA8_96.snap_44113"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.hellenNA8_96.snap_12103" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.hellenNA8_96.snap_44113" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:30 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:00 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5487,6 +5490,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.kin.snap_15459"
|
||||
signature = "rusEFI 2022.11.27.kin.snap_49013"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.kin.snap_15459" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.kin.snap_49013" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 27 14:13:12 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 27 23:27:35 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.mre_f4.snap_63919"
|
||||
signature = "rusEFI 2022.11.27.mre_f4.snap_31417"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.mre_f4.snap_63919" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.mre_f4.snap_31417" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:33 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:03 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5488,6 +5491,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.mre_f7.snap_63919"
|
||||
signature = "rusEFI 2022.11.27.mre_f7.snap_31417"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.mre_f7.snap_63919" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.mre_f7.snap_31417" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:32 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:01 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5488,6 +5491,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.prometheus_405.snap_18249"
|
||||
signature = "rusEFI 2022.11.27.prometheus_405.snap_50271"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.prometheus_405.snap_18249" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.prometheus_405.snap_50271" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:39 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:10 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5484,6 +5487,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.prometheus_469.snap_18249"
|
||||
signature = "rusEFI 2022.11.27.prometheus_469.snap_50271"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.prometheus_469.snap_18249" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.prometheus_469.snap_50271" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:37 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:09 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5484,6 +5487,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.proteus_f4.snap_23001"
|
||||
signature = "rusEFI 2022.11.27.proteus_f4.snap_56015"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.proteus_f4.snap_23001" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.proteus_f4.snap_56015" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:41 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:14 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5484,6 +5487,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.proteus_f7.snap_23001"
|
||||
signature = "rusEFI 2022.11.27.proteus_f7.snap_56015"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.proteus_f7.snap_23001" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.proteus_f7.snap_56015" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:40 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:12 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5484,6 +5487,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.proteus_h7.snap_23001"
|
||||
signature = "rusEFI 2022.11.27.proteus_h7.snap_56015"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.proteus_h7.snap_23001" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.proteus_h7.snap_56015" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:42 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:15 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5484,6 +5487,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.subaru_eg33_f7.snap_18293"
|
||||
signature = "rusEFI 2022.11.27.subaru_eg33_f7.snap_50275"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.subaru_eg33_f7.snap_18293" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.subaru_eg33_f7.snap_50275" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_subaru_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:14 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_subaru_config.sh integration/rusefi_config.txt Sun Nov 27 23:27:37 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5486,6 +5489,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -33,12 +33,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2022.11.27.tdg-pdm8.snap_20731"
|
||||
signature = "rusEFI 2022.11.27.tdg-pdm8.snap_54253"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmware version for title bar.
|
||||
signature= "rusEFI 2022.11.27.tdg-pdm8.snap_20731" ; signature is expected to be 7 or more characters.
|
||||
signature= "rusEFI 2022.11.27.tdg-pdm8.snap_54253" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -86,7 +86,7 @@ enable2ndByteCanID = false
|
|||
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
|
||||
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:47 UTC 2022
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:21 UTC 2022
|
||||
|
||||
pageSize = 22800
|
||||
page = 1
|
||||
|
@ -2128,7 +2128,7 @@ veBlends4_blendValues = array, U08, 22790, [8], "%", 0.5, 0, 0, 100, 1
|
|||
ochGetCommand = "O%2o%2c"
|
||||
|
||||
; see TS_OUTPUT_SIZE in console source code
|
||||
ochBlockSize = 1260
|
||||
ochBlockSize = 1264
|
||||
|
||||
; 11.2.3 Full Optimized – High Speed
|
||||
scatteredOchGetCommand = 9
|
||||
|
@ -2818,14 +2818,15 @@ etbIntegralError = scalar, F32, 1232, "", 1, 0
|
|||
etbCurrentTarget = scalar, F32, 1236, "%", 1, 0
|
||||
etbCurrentAdjustedTarget = scalar, F32, 1240, "%", 1, 0
|
||||
etbRevLimitActive = bits, U32, 1244, [0:0]
|
||||
; total TS size = 1248
|
||||
faultCode = scalar, U08, 1248, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1249, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1250, "%", 1, 0
|
||||
tempC = scalar, U16, 1252, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1254, "V", 0.001, 0
|
||||
esr = scalar, U16, 1256, "", 1, 0
|
||||
; total TS size = 1260
|
||||
etbDutyRateOfChange = scalar, F32, 1248, "", 1, 0
|
||||
; total TS size = 1252
|
||||
faultCode = scalar, U08, 1252, "", 1, 0
|
||||
heaterDuty = scalar, U08, 1253, "%", 1, 0
|
||||
pumpDuty = scalar, U08, 1254, "%", 1, 0
|
||||
tempC = scalar, U16, 1256, "C", 1, 0
|
||||
nernstVoltage = scalar, U16, 1258, "V", 0.001, 0
|
||||
esr = scalar, U16, 1260, "", 1, 0
|
||||
; total TS size = 1264
|
||||
|
||||
|
||||
time = { timeNow }
|
||||
|
@ -3984,6 +3985,7 @@ gaugeCategory = Throttle Body (incl. ETB)
|
|||
etbTargetGauge = etbTarget, "ETB position target", "%", 0, 100, 0, 0, 100, 100, 1, 1
|
||||
etbErrorGauge = etb1Error, "ETB position error", "%", -20, 20, -10, -5, 5, 10, 2, 0
|
||||
etbDutyCycleGauge = etb1DutyCycle, "ETB Duty", "%", -100, 100, -75, -50, 50, 75, 0, 0
|
||||
etbDutyRateOfChangeGauge = etbDutyRateOfChange, "ETB duty ROC", "", -100, 100, -75, -50, 50, 75, 0, 3
|
||||
|
||||
gaugeCategory = Sensors - Raw
|
||||
rawTps1PrimaryGauge = rawTps1Primary, "Raw TPS 1 Primary", "V", 0, 5, 0, 0, 5, 5, 3, 0
|
||||
|
@ -4659,6 +4661,7 @@ entry = etbIntegralError, "etbIntegralError", float, "%.3f"
|
|||
entry = etbCurrentTarget, "etbCurrentTarget", float, "%.3f"
|
||||
entry = etbCurrentAdjustedTarget, "etbCurrentAdjustedTarget", float, "%.3f"
|
||||
entry = etbRevLimitActive, "etbRevLimitActive", int, "%d"
|
||||
entry = etbDutyRateOfChange, "etbDutyRateOfChange", float, "%.3f"
|
||||
entry = faultCode, "faultCode", int, "%d"
|
||||
entry = heaterDuty, "heaterDuty", int, "%d"
|
||||
entry = pumpDuty, "pumpDuty", int, "%d"
|
||||
|
@ -5490,6 +5493,7 @@ dialog = electronic_throttleDialog, "electronic_throttle"
|
|||
graphLine = etbIntegralError
|
||||
graphLine = etbCurrentTarget
|
||||
graphLine = etbCurrentAdjustedTarget
|
||||
graphLine = etbDutyRateOfChange
|
||||
|
||||
|
||||
dialog = wideband_stateDialog, "wideband_state"
|
||||
|
|
|
@ -1,6 +1,6 @@
|
|||
package com.rusefi.config.generated;
|
||||
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/actuators/electronic_throttle.txt Sat Nov 26 05:37:37 UTC 2022
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/actuators/electronic_throttle.txt Sun Nov 27 23:27:34 UTC 2022
|
||||
|
||||
// by class com.rusefi.output.FileJavaFieldsConsumer
|
||||
import com.rusefi.config.*;
|
||||
|
@ -14,6 +14,7 @@ public class ElectronicThrottle {
|
|||
public static final Field ETBCURRENTTARGET = Field.create("ETBCURRENTTARGET", 20, FieldType.FLOAT).setBaseOffset(1216);
|
||||
public static final Field ETBCURRENTADJUSTEDTARGET = Field.create("ETBCURRENTADJUSTEDTARGET", 24, FieldType.FLOAT).setBaseOffset(1216);
|
||||
public static final Field ETBREVLIMITACTIVE = Field.create("ETBREVLIMITACTIVE", 28, FieldType.BIT, 0).setBaseOffset(1216);
|
||||
public static final Field ETBDUTYRATEOFCHANGE = Field.create("ETBDUTYRATEOFCHANGE", 32, FieldType.FLOAT).setBaseOffset(1216);
|
||||
public static final Field[] VALUES = {
|
||||
IDLEPOSITION,
|
||||
TRIM,
|
||||
|
@ -23,5 +24,6 @@ public class ElectronicThrottle {
|
|||
ETBCURRENTTARGET,
|
||||
ETBCURRENTADJUSTEDTARGET,
|
||||
ETBREVLIMITACTIVE,
|
||||
ETBDUTYRATEOFCHANGE,
|
||||
};
|
||||
}
|
||||
|
|
|
@ -1,6 +1,6 @@
|
|||
package com.rusefi.config.generated;
|
||||
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 14:13:50 UTC 2022
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 27 23:28:27 UTC 2022
|
||||
|
||||
// by class com.rusefi.output.FileJavaFieldsConsumer
|
||||
import com.rusefi.config.*;
|
||||
|
@ -1182,10 +1182,10 @@ public class Fields {
|
|||
public static final int TS_RESPONSE_UNDERRUN = 0x80;
|
||||
public static final int TS_RESPONSE_UNRECOGNIZED_COMMAND = 0x83;
|
||||
public static final char TS_SET_LOGGER_SWITCH = 'l';
|
||||
public static final String TS_SIGNATURE = "rusEFI 2022.11.27.all.snap_40623";
|
||||
public static final String TS_SIGNATURE = "rusEFI 2022.11.27.all.snap_7609";
|
||||
public static final char TS_SINGLE_WRITE_COMMAND = 'W';
|
||||
public static final char TS_TEST_COMMAND = 't';
|
||||
public static final int TS_TOTAL_OUTPUT_SIZE = 1260;
|
||||
public static final int TS_TOTAL_OUTPUT_SIZE = 1264;
|
||||
public static final int TsCalMode_EtbKd = 5;
|
||||
public static final int TsCalMode_EtbKi = 4;
|
||||
public static final int TsCalMode_EtbKp = 3;
|
||||
|
|
|
@ -1,19 +1,19 @@
|
|||
package com.rusefi.config.generated;
|
||||
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/sensors/\wideband_state.txt Sat Nov 26 00:29:02 EST 2022
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) controllers/sensors//wideband_state.txt Sun Nov 27 23:27:34 UTC 2022
|
||||
|
||||
// by class com.rusefi.output.FileJavaFieldsConsumer
|
||||
import com.rusefi.config.*;
|
||||
|
||||
public class WidebandController {
|
||||
public static final Field FAULTCODE = Field.create("FAULTCODE", 0, FieldType.INT8).setScale(1.0).setBaseOffset(1248);
|
||||
public static final Field HEATERDUTY = Field.create("HEATERDUTY", 1, FieldType.INT8).setScale(1.0).setBaseOffset(1248);
|
||||
public static final Field PUMPDUTY = Field.create("PUMPDUTY", 2, FieldType.INT8).setScale(1.0).setBaseOffset(1248);
|
||||
public static final Field ALIGNMENTFILL_AT_3 = Field.create("ALIGNMENTFILL_AT_3", 3, FieldType.INT8).setScale(1.0).setBaseOffset(1248);
|
||||
public static final Field TEMPC = Field.create("TEMPC", 4, FieldType.INT16).setScale(1.0).setBaseOffset(1248);
|
||||
public static final Field NERNSTVOLTAGE = Field.create("NERNSTVOLTAGE", 6, FieldType.INT16).setScale(0.001).setBaseOffset(1248);
|
||||
public static final Field ESR = Field.create("ESR", 8, FieldType.INT16).setScale(1.0).setBaseOffset(1248);
|
||||
public static final Field ALIGNMENTFILL_AT_10 = Field.create("ALIGNMENTFILL_AT_10", 10, FieldType.INT8).setScale(1.0).setBaseOffset(1248);
|
||||
public static final Field FAULTCODE = Field.create("FAULTCODE", 0, FieldType.INT8).setScale(1.0).setBaseOffset(1252);
|
||||
public static final Field HEATERDUTY = Field.create("HEATERDUTY", 1, FieldType.INT8).setScale(1.0).setBaseOffset(1252);
|
||||
public static final Field PUMPDUTY = Field.create("PUMPDUTY", 2, FieldType.INT8).setScale(1.0).setBaseOffset(1252);
|
||||
public static final Field ALIGNMENTFILL_AT_3 = Field.create("ALIGNMENTFILL_AT_3", 3, FieldType.INT8).setScale(1.0).setBaseOffset(1252);
|
||||
public static final Field TEMPC = Field.create("TEMPC", 4, FieldType.INT16).setScale(1.0).setBaseOffset(1252);
|
||||
public static final Field NERNSTVOLTAGE = Field.create("NERNSTVOLTAGE", 6, FieldType.INT16).setScale(0.001).setBaseOffset(1252);
|
||||
public static final Field ESR = Field.create("ESR", 8, FieldType.INT16).setScale(1.0).setBaseOffset(1252);
|
||||
public static final Field ALIGNMENTFILL_AT_10 = Field.create("ALIGNMENTFILL_AT_10", 10, FieldType.INT8).setScale(1.0).setBaseOffset(1252);
|
||||
public static final Field[] VALUES = {
|
||||
FAULTCODE,
|
||||
HEATERDUTY,
|
||||
|
|
Loading…