diff --git a/firmware/controllers/generated/signature_all.h b/firmware/controllers/generated/signature_all.h index f35b428149..d3e9ca4764 100644 --- a/firmware/controllers/generated/signature_all.h +++ b/firmware/controllers/generated/signature_all.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 1729809101 -#define TS_SIGNATURE "rusEFI 2021.11.14.all.1729809101" +#define SIGNATURE_HASH 2827472057 +#define TS_SIGNATURE "rusEFI 2021.11.14.all.2827472057" diff --git a/firmware/controllers/generated/signature_atlas.h b/firmware/controllers/generated/signature_atlas.h index eefeaca1ab..3bd152a435 100644 --- a/firmware/controllers/generated/signature_atlas.h +++ b/firmware/controllers/generated/signature_atlas.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 2077245418 -#define TS_SIGNATURE "rusEFI 2021.11.14.atlas.2077245418" +#define SIGNATURE_HASH 3024959902 +#define TS_SIGNATURE "rusEFI 2021.11.14.atlas.3024959902" diff --git a/firmware/controllers/generated/signature_f429-discovery.h b/firmware/controllers/generated/signature_f429-discovery.h index 907dddc618..d44d2470aa 100644 --- a/firmware/controllers/generated/signature_f429-discovery.h +++ b/firmware/controllers/generated/signature_f429-discovery.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 1729809101 -#define TS_SIGNATURE "rusEFI 2021.11.14.f429-discovery.1729809101" +#define SIGNATURE_HASH 2827472057 +#define TS_SIGNATURE "rusEFI 2021.11.14.f429-discovery.2827472057" diff --git a/firmware/controllers/generated/signature_frankenso_na6.h b/firmware/controllers/generated/signature_frankenso_na6.h index 9fe20b25c9..a93d824fc0 100644 --- a/firmware/controllers/generated/signature_frankenso_na6.h +++ b/firmware/controllers/generated/signature_frankenso_na6.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 489201444 -#define TS_SIGNATURE "rusEFI 2021.11.14.frankenso_na6.489201444" +#define SIGNATURE_HASH 3535116624 +#define TS_SIGNATURE "rusEFI 2021.11.14.frankenso_na6.3535116624" diff --git a/firmware/controllers/generated/signature_hellen-nb1.h b/firmware/controllers/generated/signature_hellen-nb1.h index 8cada8197d..6dd79b4c9f 100644 --- a/firmware/controllers/generated/signature_hellen-nb1.h +++ b/firmware/controllers/generated/signature_hellen-nb1.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 3267951172 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen-nb1.3267951172" +#define SIGNATURE_HASH 223738928 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen-nb1.223738928" diff --git a/firmware/controllers/generated/signature_hellen121nissan.h b/firmware/controllers/generated/signature_hellen121nissan.h index 24be959265..2cab6aba3a 100644 --- a/firmware/controllers/generated/signature_hellen121nissan.h +++ b/firmware/controllers/generated/signature_hellen121nissan.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 3701385324 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121nissan.3701385324" +#define SIGNATURE_HASH 319008280 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121nissan.319008280" diff --git a/firmware/controllers/generated/signature_hellen121vag.h b/firmware/controllers/generated/signature_hellen121vag.h index 6f2b35624b..4825a4a7e7 100644 --- a/firmware/controllers/generated/signature_hellen121vag.h +++ b/firmware/controllers/generated/signature_hellen121vag.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 951709383 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121vag.951709383" +#define SIGNATURE_HASH 4146391219 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121vag.4146391219" diff --git a/firmware/controllers/generated/signature_hellen128.h b/firmware/controllers/generated/signature_hellen128.h index 4d18585a00..e1855d9013 100644 --- a/firmware/controllers/generated/signature_hellen128.h +++ b/firmware/controllers/generated/signature_hellen128.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 4259094890 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen128.4259094890" +#define SIGNATURE_HASH 843163422 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen128.843163422" diff --git a/firmware/controllers/generated/signature_hellen154hyundai.h b/firmware/controllers/generated/signature_hellen154hyundai.h index 982428f870..5e39e53d81 100644 --- a/firmware/controllers/generated/signature_hellen154hyundai.h +++ b/firmware/controllers/generated/signature_hellen154hyundai.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 1171179627 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen154hyundai.1171179627" +#define SIGNATURE_HASH 2320748063 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen154hyundai.2320748063" diff --git a/firmware/controllers/generated/signature_hellen72.h b/firmware/controllers/generated/signature_hellen72.h index 132e607260..b46dd35670 100644 --- a/firmware/controllers/generated/signature_hellen72.h +++ b/firmware/controllers/generated/signature_hellen72.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 2477215101 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen72.2477215101" +#define SIGNATURE_HASH 1547324169 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen72.1547324169" diff --git a/firmware/controllers/generated/signature_hellen88bmw.h b/firmware/controllers/generated/signature_hellen88bmw.h index c0319bdd09..919f355f64 100644 --- a/firmware/controllers/generated/signature_hellen88bmw.h +++ b/firmware/controllers/generated/signature_hellen88bmw.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 3336199058 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen88bmw.3336199058" +#define SIGNATURE_HASH 155672038 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen88bmw.155672038" diff --git a/firmware/controllers/generated/signature_hellenNA6.h b/firmware/controllers/generated/signature_hellenNA6.h index fcdb5c4f1e..540404e29d 100644 --- a/firmware/controllers/generated/signature_hellenNA6.h +++ b/firmware/controllers/generated/signature_hellenNA6.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 287804517 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellenNA6.287804517" +#define SIGNATURE_HASH 3736766993 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellenNA6.3736766993" diff --git a/firmware/controllers/generated/signature_hellen_cypress.h b/firmware/controllers/generated/signature_hellen_cypress.h index f8b108fae0..7b19c3a2ba 100644 --- a/firmware/controllers/generated/signature_hellen_cypress.h +++ b/firmware/controllers/generated/signature_hellen_cypress.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt // -#define SIGNATURE_HASH 1575955825 -#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.1575955825" +#define SIGNATURE_HASH 2456955653 +#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.2456955653" diff --git a/firmware/controllers/generated/signature_kin.h b/firmware/controllers/generated/signature_kin.h index 51395a9aa3..e1aeb766c2 100644 --- a/firmware/controllers/generated/signature_kin.h +++ b/firmware/controllers/generated/signature_kin.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt // -#define SIGNATURE_HASH 2722816397 -#define TS_SIGNATURE "rusEFI 2021.11.14.kin.2722816397" +#define SIGNATURE_HASH 1842866169 +#define TS_SIGNATURE "rusEFI 2021.11.14.kin.1842866169" diff --git a/firmware/controllers/generated/signature_mre_f4.h b/firmware/controllers/generated/signature_mre_f4.h index 6078687a3a..734549f121 100644 --- a/firmware/controllers/generated/signature_mre_f4.h +++ b/firmware/controllers/generated/signature_mre_f4.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 3963724140 -#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f4.3963724140" +#define SIGNATURE_HASH 601663256 +#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f4.601663256" diff --git a/firmware/controllers/generated/signature_mre_f7.h b/firmware/controllers/generated/signature_mre_f7.h index 02f4c2ed48..006a2daad9 100644 --- a/firmware/controllers/generated/signature_mre_f7.h +++ b/firmware/controllers/generated/signature_mre_f7.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 3963724140 -#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f7.3963724140" +#define SIGNATURE_HASH 601663256 +#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f7.601663256" diff --git a/firmware/controllers/generated/signature_prometheus_405.h b/firmware/controllers/generated/signature_prometheus_405.h index 0f48e9f45a..19cb9a89b5 100644 --- a/firmware/controllers/generated/signature_prometheus_405.h +++ b/firmware/controllers/generated/signature_prometheus_405.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 938480427 -#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_405.938480427" +#define SIGNATURE_HASH 4167898463 +#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_405.4167898463" diff --git a/firmware/controllers/generated/signature_prometheus_469.h b/firmware/controllers/generated/signature_prometheus_469.h index fdb3f6ef00..26142002a6 100644 --- a/firmware/controllers/generated/signature_prometheus_469.h +++ b/firmware/controllers/generated/signature_prometheus_469.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 938480427 -#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_469.938480427" +#define SIGNATURE_HASH 4167898463 +#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_469.4167898463" diff --git a/firmware/controllers/generated/signature_proteus_f4.h b/firmware/controllers/generated/signature_proteus_f4.h index 9e9bbf9ad0..7ab951251e 100644 --- a/firmware/controllers/generated/signature_proteus_f4.h +++ b/firmware/controllers/generated/signature_proteus_f4.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 3429212492 -#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f4.3429212492" +#define SIGNATURE_HASH 66627384 +#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f4.66627384" diff --git a/firmware/controllers/generated/signature_proteus_f7.h b/firmware/controllers/generated/signature_proteus_f7.h index 31a091cc38..2f0111c14d 100644 --- a/firmware/controllers/generated/signature_proteus_f7.h +++ b/firmware/controllers/generated/signature_proteus_f7.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 3429212492 -#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f7.3429212492" +#define SIGNATURE_HASH 66627384 +#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f7.66627384" diff --git a/firmware/controllers/generated/signature_subaru_eg33_f7.h b/firmware/controllers/generated/signature_subaru_eg33_f7.h index a5e8015df9..36c68b0f29 100644 --- a/firmware/controllers/generated/signature_subaru_eg33_f7.h +++ b/firmware/controllers/generated/signature_subaru_eg33_f7.h @@ -2,5 +2,5 @@ // was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt // -#define SIGNATURE_HASH 2762005661 -#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.2762005661" +#define SIGNATURE_HASH 1799215849 +#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.1799215849" diff --git a/firmware/tunerstudio/generated/cache.zip b/firmware/tunerstudio/generated/cache.zip index d51273df5a..d0ebbbccff 100644 Binary files a/firmware/tunerstudio/generated/cache.zip and b/firmware/tunerstudio/generated/cache.zip differ diff --git a/firmware/tunerstudio/generated/rusefi.ini b/firmware/tunerstudio/generated/rusefi.ini index 4ec2605910..e621d2e9ba 100644 --- a/firmware/tunerstudio/generated/rusefi.ini +++ b/firmware/tunerstudio/generated/rusefi.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.all.1729809101" + signature = "rusEFI 2021.11.14.all.2827472057" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.all.1729809101" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.all.2827472057" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:40 UTC 2021 pageSize = 20000 page = 1 @@ -4243,12 +4243,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4264,12 +4258,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5140,28 +5128,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_atlas.ini b/firmware/tunerstudio/generated/rusefi_atlas.ini index 96392a8e57..9162371950 100644 --- a/firmware/tunerstudio/generated/rusefi_atlas.ini +++ b/firmware/tunerstudio/generated/rusefi_atlas.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.atlas.2077245418" + signature = "rusEFI 2021.11.14.atlas.3024959902" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.atlas.2077245418" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.atlas.3024959902" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:32 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:36 UTC 2021 pageSize = 20000 page = 1 @@ -4235,12 +4235,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4256,12 +4250,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5132,28 +5120,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_f429-discovery.ini b/firmware/tunerstudio/generated/rusefi_f429-discovery.ini index a155d87018..49ebec84e3 100644 --- a/firmware/tunerstudio/generated/rusefi_f429-discovery.ini +++ b/firmware/tunerstudio/generated/rusefi_f429-discovery.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.f429-discovery.1729809101" + signature = "rusEFI 2021.11.14.f429-discovery.2827472057" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.f429-discovery.1729809101" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.f429-discovery.2827472057" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:39 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:39:37 UTC 2021 pageSize = 20000 page = 1 @@ -4243,12 +4243,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4264,12 +4258,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5140,28 +5128,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_frankenso_na6.ini b/firmware/tunerstudio/generated/rusefi_frankenso_na6.ini index eceff3ceab..b98c878990 100644 --- a/firmware/tunerstudio/generated/rusefi_frankenso_na6.ini +++ b/firmware/tunerstudio/generated/rusefi_frankenso_na6.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.frankenso_na6.489201444" + signature = "rusEFI 2021.11.14.frankenso_na6.3535116624" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.frankenso_na6.489201444" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.frankenso_na6.3535116624" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:15 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:18 UTC 2021 pageSize = 20000 page = 1 @@ -4243,12 +4243,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4264,12 +4258,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5140,28 +5128,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen-nb1.ini b/firmware/tunerstudio/generated/rusefi_hellen-nb1.ini index d7941d1ab4..b8cda5f008 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen-nb1.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen-nb1.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen-nb1.3267951172" + signature = "rusEFI 2021.11.14.hellen-nb1.223738928" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen-nb1.3267951172" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen-nb1.223738928" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:03 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:03 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5117,28 +5105,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen121nissan.ini b/firmware/tunerstudio/generated/rusefi_hellen121nissan.ini index 9d7f65c1ba..2e5c7ffbd2 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen121nissan.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen121nissan.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen121nissan.3701385324" + signature = "rusEFI 2021.11.14.hellen121nissan.319008280" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen121nissan.3701385324" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen121nissan.319008280" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:49 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:39:48 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5116,28 +5104,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen121vag.ini b/firmware/tunerstudio/generated/rusefi_hellen121vag.ini index 39e36f23c1..5d0cb8ffa3 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen121vag.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen121vag.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen121vag.951709383" + signature = "rusEFI 2021.11.14.hellen121vag.4146391219" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen121vag.951709383" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen121vag.4146391219" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:46 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:39:44 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5116,28 +5104,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen128mercedes.ini b/firmware/tunerstudio/generated/rusefi_hellen128mercedes.ini index d186db62ab..80025e8586 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen128mercedes.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen128mercedes.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen128.4259094890" + signature = "rusEFI 2021.11.14.hellen128.843163422" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen128.4259094890" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen128.843163422" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:43 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:39:41 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5116,28 +5104,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen154hyundai.ini b/firmware/tunerstudio/generated/rusefi_hellen154hyundai.ini index 4da55edb06..67b7efe585 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen154hyundai.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen154hyundai.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen154hyundai.1171179627" + signature = "rusEFI 2021.11.14.hellen154hyundai.2320748063" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen154hyundai.1171179627" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen154hyundai.2320748063" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:53 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:39:52 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5116,28 +5104,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen72.ini b/firmware/tunerstudio/generated/rusefi_hellen72.ini index 8c53cedc71..d46f6f97a1 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen72.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen72.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen72.2477215101" + signature = "rusEFI 2021.11.14.hellen72.1547324169" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen72.2477215101" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen72.1547324169" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:59 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:39:59 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5117,28 +5105,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen88bmw.ini b/firmware/tunerstudio/generated/rusefi_hellen88bmw.ini index 209fe2d4a7..7ce1bf459b 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen88bmw.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen88bmw.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen88bmw.3336199058" + signature = "rusEFI 2021.11.14.hellen88bmw.155672038" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen88bmw.3336199058" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen88bmw.155672038" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:56 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:39:56 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5116,28 +5104,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellenNA6.ini b/firmware/tunerstudio/generated/rusefi_hellenNA6.ini index 9198d5ea48..22c377a868 100644 --- a/firmware/tunerstudio/generated/rusefi_hellenNA6.ini +++ b/firmware/tunerstudio/generated/rusefi_hellenNA6.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellenNA6.287804517" + signature = "rusEFI 2021.11.14.hellenNA6.3736766993" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellenNA6.287804517" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellenNA6.3736766993" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:06 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:07 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5117,28 +5105,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_hellen_cypress.ini b/firmware/tunerstudio/generated/rusefi_hellen_cypress.ini index 1ee2e19203..9bb76aaa94 100644 --- a/firmware/tunerstudio/generated/rusefi_hellen_cypress.ini +++ b/firmware/tunerstudio/generated/rusefi_hellen_cypress.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.hellen_cypress.1575955825" + signature = "rusEFI 2021.11.14.hellen_cypress.2456955653" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.hellen_cypress.1575955825" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.hellen_cypress.2456955653" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:41 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 17:40:47 UTC 2021 pageSize = 20000 page = 1 @@ -4243,12 +4243,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4264,12 +4258,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5140,28 +5128,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_kinetis.ini b/firmware/tunerstudio/generated/rusefi_kinetis.ini index f23b731f96..4b9d28df5e 100644 --- a/firmware/tunerstudio/generated/rusefi_kinetis.ini +++ b/firmware/tunerstudio/generated/rusefi_kinetis.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.kin.2722816397" + signature = "rusEFI 2021.11.14.kin.1842866169" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.kin.2722816397" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.kin.1842866169" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:38 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 17:40:44 UTC 2021 pageSize = 19972 page = 1 @@ -4210,12 +4210,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4231,12 +4225,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5107,28 +5095,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_mre_f4.ini b/firmware/tunerstudio/generated/rusefi_mre_f4.ini index c20f359a06..7a51a3042e 100644 --- a/firmware/tunerstudio/generated/rusefi_mre_f4.ini +++ b/firmware/tunerstudio/generated/rusefi_mre_f4.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.mre_f4.3963724140" + signature = "rusEFI 2021.11.14.mre_f4.601663256" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.mre_f4.3963724140" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.mre_f4.601663256" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:12 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:14 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5115,28 +5103,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_mre_f7.ini b/firmware/tunerstudio/generated/rusefi_mre_f7.ini index 83f5605579..6c18c06a89 100644 --- a/firmware/tunerstudio/generated/rusefi_mre_f7.ini +++ b/firmware/tunerstudio/generated/rusefi_mre_f7.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.mre_f7.3963724140" + signature = "rusEFI 2021.11.14.mre_f7.601663256" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.mre_f7.3963724140" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.mre_f7.601663256" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:09 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:10 UTC 2021 pageSize = 20000 page = 1 @@ -4231,12 +4231,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4252,12 +4246,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5115,28 +5103,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_prometheus_405.ini b/firmware/tunerstudio/generated/rusefi_prometheus_405.ini index e31ff47b01..379856c090 100644 --- a/firmware/tunerstudio/generated/rusefi_prometheus_405.ini +++ b/firmware/tunerstudio/generated/rusefi_prometheus_405.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.prometheus_405.938480427" + signature = "rusEFI 2021.11.14.prometheus_405.4167898463" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.prometheus_405.938480427" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.prometheus_405.4167898463" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:22 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:25 UTC 2021 pageSize = 20000 page = 1 @@ -4238,12 +4238,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4259,12 +4253,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5135,28 +5123,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_prometheus_469.ini b/firmware/tunerstudio/generated/rusefi_prometheus_469.ini index 10eb90abed..104602604b 100644 --- a/firmware/tunerstudio/generated/rusefi_prometheus_469.ini +++ b/firmware/tunerstudio/generated/rusefi_prometheus_469.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.prometheus_469.938480427" + signature = "rusEFI 2021.11.14.prometheus_469.4167898463" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.prometheus_469.938480427" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.prometheus_469.4167898463" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:19 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:22 UTC 2021 pageSize = 20000 page = 1 @@ -4238,12 +4238,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4259,12 +4253,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5135,28 +5123,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_proteus_f4.ini b/firmware/tunerstudio/generated/rusefi_proteus_f4.ini index 33aa659aee..fa39b9a4ef 100644 --- a/firmware/tunerstudio/generated/rusefi_proteus_f4.ini +++ b/firmware/tunerstudio/generated/rusefi_proteus_f4.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.proteus_f4.3429212492" + signature = "rusEFI 2021.11.14.proteus_f4.66627384" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.proteus_f4.3429212492" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.proteus_f4.66627384" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:28 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:32 UTC 2021 pageSize = 20000 page = 1 @@ -4236,12 +4236,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4257,12 +4251,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5108,28 +5096,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_proteus_f7.ini b/firmware/tunerstudio/generated/rusefi_proteus_f7.ini index 5c499e49c5..e4ffe68d67 100644 --- a/firmware/tunerstudio/generated/rusefi_proteus_f7.ini +++ b/firmware/tunerstudio/generated/rusefi_proteus_f7.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.proteus_f7.3429212492" + signature = "rusEFI 2021.11.14.proteus_f7.66627384" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.proteus_f7.3429212492" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.proteus_f7.66627384" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:25 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:29 UTC 2021 pageSize = 20000 page = 1 @@ -4236,12 +4236,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4257,12 +4251,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5108,28 +5096,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number." diff --git a/firmware/tunerstudio/generated/rusefi_subaru_eg33_f7.ini b/firmware/tunerstudio/generated/rusefi_subaru_eg33_f7.ini index c4fcca59f5..729f290299 100644 --- a/firmware/tunerstudio/generated/rusefi_subaru_eg33_f7.ini +++ b/firmware/tunerstudio/generated/rusefi_subaru_eg33_f7.ini @@ -32,12 +32,12 @@ enable2ndByteCanID = false [MegaTune] ; https://rusefi.com/forum/viewtopic.php?p=36201#p36201 - signature = "rusEFI 2021.11.14.subaru_eg33_f7.2762005661" + signature = "rusEFI 2021.11.14.subaru_eg33_f7.1799215849" [TunerStudio] queryCommand = "S" versionInfo = "V" ; firmwave version for title bar. - signature = "rusEFI 2021.11.14.subaru_eg33_f7.2762005661" ; signature is expected to be 7 or more characters. + signature = "rusEFI 2021.11.14.subaru_eg33_f7.1799215849" ; signature is expected to be 7 or more characters. ; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C useLegacyFTempUnits = false @@ -85,7 +85,7 @@ enable2ndByteCanID = false ; see PAGE_0_SIZE in C source code ; CONFIG_DEFINITION_START -; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:44 UTC 2021 +; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 17:40:50 UTC 2021 pageSize = 20000 page = 1 @@ -4239,12 +4239,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Injection Pin 10 ", injectionPins10 field = "Injection Pin 11 ", injectionPins11 field = "Injection Pin 12 ", injectionPins12 - field = "FSIO dig inp #1", fsioDigitalInputs1 - field = "FSIO dig inp #2", fsioDigitalInputs2 - field = "FSIO dig inp #3", fsioDigitalInputs3 - field = "FSIO dig inp #4", fsioDigitalInputs4 - field = "FSIO dig inp #5", fsioDigitalInputs5 - field = "FSIO dig inp #6", fsioDigitalInputs6 dialog = allPins2_2 @@ -4260,12 +4254,6 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "Ignition Pin 10", ignitionPins10 field = "Ignition Pin 11", ignitionPins11 field = "Ignition Pin 12", ignitionPins12 - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 dialog = allPins2_3 field = "LCD E pin", HD44780_e @@ -5131,28 +5119,10 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00" field = "No accel after RPM hard limit", noAccelAfterHardLimitPeriodSecs -; Flex Logic - dialog = fsioIO, "Outputs" - field = "output #1", fsioOutputPins1 - field = "output #2", fsioOutputPins2 - field = "output #3", fsioOutputPins3 - field = "output #4", fsioOutputPins4 - field = "output #5", fsioOutputPins5 - field = "output #6", fsioOutputPins6 - + dialog = auxValvesIO, "Outputs" field = "aux valve #1", auxValves1 field = "aux valve #2", auxValves2 - - dialog = fsioFrequency, "Frequency" - field = "freq #1", fsioFrequency1 - field = "freq #2", fsioFrequency2 - field = "freq #3", fsioFrequency3 - field = "freq #4", fsioFrequency4 - field = "freq #5", fsioFrequency5 - field = "freq #6", fsioFrequency6 - field = "" - field = "" - + dialog = scriptSetting, "Setting" field = "!Use rusEFI console for Lua script editing" field = "Set number is not associated with the output number."