don't write settings if cal didn't work (#2154)
Co-authored-by: Matthew Kennedy <makenne@microsoft.com>
This commit is contained in:
parent
4555a98836
commit
ec508d8f9d
|
@ -605,6 +605,13 @@ struct EtbImpl final : public EtbController {
|
|||
// Finally disable and reset state
|
||||
motor->disable();
|
||||
|
||||
// Check that the calibrate actually moved the throttle
|
||||
if (absF(primaryMax - primaryMin) < 0.5f) {
|
||||
firmwareError(OBD_Throttle_Position_Sensor_Circuit_Malfunction, "Auto calibrate failed, check your wiring!\r\nClosed voltage: %.1fv Open voltage: %.1fv", primaryMin, primaryMax);
|
||||
m_isAutocal = false;
|
||||
return;
|
||||
}
|
||||
|
||||
// Write out the learned values to TS, waiting briefly after setting each to let TS grab it
|
||||
tsOutputChannels.calibrationMode = functionToCalModePriMax(myFunction);
|
||||
tsOutputChannels.calibrationValue = primaryMax;
|
||||
|
|
Loading…