9 lines
796 B
Plaintext
9 lines
796 B
Plaintext
1) RESOLVED IN R0.1 Schematic zone G4 and G5, blue text claims INJ5 as INJ3, and INJ6 as INJ4
|
|
2) RESOLVED IN R0.1 Schematic inj1 and 2 are flipped, nets are flipped. Change net names and correct blue silk screen note.
|
|
3) RESOLVED IN R0.1 Add silk screen to designate injector # and similar.
|
|
4) RESOLVED IN R0.1 Move C26, it's currently under an inductor. 2 parts can not sit in the same physical space
|
|
5) RESOLVED IN R0.1 Add via for battery wire to be attached.
|
|
6) RESOLVED IN R0.1 check for flipped pins. pins 39 and 50 are wrong.
|
|
7) RESOLVED IN R0.1 ?D2?, D11_1, D10, D10_1, D11 and D11_2 are likely botched. Check them against MC33816 R0.2 layout. dual package into one package
|
|