Do not attempt to perform a priming pulse or pump prime if set to 0

This commit is contained in:
Josh Stewart 2018-09-19 16:40:03 +10:00
parent de5fd0d175
commit a21f0eb63f
1 changed files with 16 additions and 6 deletions

View File

@ -833,14 +833,24 @@ void setup()
}
//Begin priming the fuel pump. This is turned off in the low resolution, 1s interrupt in timers.ino
FUEL_PUMP_ON();
currentStatus.fuelPumpOn = true;
//First check that the priming time is not 0
if(configPage2.fpPrime > 0)
{
FUEL_PUMP_ON();
currentStatus.fuelPumpOn = true;
}
else { fpPrimed = true; } //If the user has set 0 for the pump priming, immediately mark the priming as being completed
interrupts();
//Perform the priming pulses. Set these to run at an arbitrary time in the future (100us). The prime pulse value is in ms*10, so need to multiple by 100 to get to uS
setFuelSchedule1(100, (unsigned long)(configPage2.primePulse * 100));
setFuelSchedule2(100, (unsigned long)(configPage2.primePulse * 100));
setFuelSchedule3(100, (unsigned long)(configPage2.primePulse * 100));
setFuelSchedule4(100, (unsigned long)(configPage2.primePulse * 100));
if(configPage2.primePulse > 0)
{
setFuelSchedule1(100, (unsigned long)(configPage2.primePulse * 100));
setFuelSchedule2(100, (unsigned long)(configPage2.primePulse * 100));
setFuelSchedule3(100, (unsigned long)(configPage2.primePulse * 100));
setFuelSchedule4(100, (unsigned long)(configPage2.primePulse * 100));
}
initialisationComplete = true;
digitalWrite(LED_BUILTIN, HIGH);