Appropriate MAP mapping for MPX4250
This commit is contained in:
parent
81f977ed14
commit
eadd5e53b2
|
@ -247,7 +247,7 @@ void loop()
|
|||
//***SET STATUSES***
|
||||
//-----------------------------------------------------------------------------------------------------
|
||||
currentStatus.TPSlast = currentStatus.TPS;
|
||||
currentStatus.MAP = fastMap(analogRead(pinMAP), 0, 1023, 0, 100); //Get the current MAP value
|
||||
currentStatus.MAP = fastMap(analogRead(pinMAP), 0, 1023, 10, 260); //Get the current MAP value
|
||||
currentStatus.tpsADC = fastMap(analogRead(pinTPS), 0, 1023, 0, 255); //Get the current raw TPS ADC value and map it into a byte
|
||||
currentStatus.TPS = fastMap(currentStatus.tpsADC, configPage1.tpsMin, configPage1.tpsMax, 0, 100); //Take the raw TPS ADC value and convert it into a TPS% based on the calibrated values
|
||||
currentStatus.O2 = fastMap(analogRead(pinO2), 0, 1023, 117, 358); //Get the current O2 value. Calibration is from AFR values 7.35 to 22.4, then multiplied by 16 (<< 4). This is the correct calibration for an Innovate Wideband 0v - 5V unit
|
||||
|
|