Make sure to read 2 bytes in EEPROM calibration load
This commit is contained in:
parent
6c20f6d5b8
commit
30cf2348ab
16
storage.ino
16
storage.ino
|
@ -158,15 +158,17 @@ void loadCalibration()
|
|||
|
||||
for(byte x=0; x<3; x++)
|
||||
{
|
||||
int y = 2*x;
|
||||
cltCalibrationTable.axisX16[x] = EEPROM.read( (EEPROM_CALIBRATION_CLT + y) );
|
||||
cltCalibrationTable.values16[x] = EEPROM.read( (EEPROM_CALIBRATION_CLT + y + 1) );
|
||||
int y = EEPROM_CALIBRATION_CLT + (2*x);
|
||||
cltCalibrationTable.axisX16[x] = int(word(EEPROM.read(y), EEPROM.read(y+1)));
|
||||
cltCalibrationTable.values16[x] = int(word(EEPROM.read(y+2), EEPROM.read(y+3)));
|
||||
|
||||
iatCalibrationTable.axisX16[x] = EEPROM.read( (EEPROM_CALIBRATION_IAT + y) );
|
||||
iatCalibrationTable.values16[x] = EEPROM.read( (EEPROM_CALIBRATION_IAT + y + 1) );
|
||||
y = EEPROM_CALIBRATION_IAT + (2*x);
|
||||
iatCalibrationTable.axisX16[x] = int(word(EEPROM.read(y), EEPROM.read(y+1)));
|
||||
iatCalibrationTable.values16[x] = int(word(EEPROM.read(y+2), EEPROM.read(y+3)));
|
||||
|
||||
o2CalibrationTable.axisX16[x] = EEPROM.read( (EEPROM_CALIBRATION_O2 + y) );
|
||||
o2CalibrationTable.values16[x] = EEPROM.read( (EEPROM_CALIBRATION_O2 + y + 1) );
|
||||
y = EEPROM_CALIBRATION_O2 + (2*x);
|
||||
o2CalibrationTable.axisX16[x] = int(word(EEPROM.read(y), EEPROM.read(y+1)));
|
||||
o2CalibrationTable.values16[x] = int(word(EEPROM.read(y+2), EEPROM.read(y+3)));
|
||||
}
|
||||
|
||||
}
|
||||
|
|