Lower max on IAT and CLT gauges for celsius (#958)
* Lower max on IAT and CLT gauges * CLT, IAT and FuelTemp gauges to max 120c/248f
This commit is contained in:
parent
7062f5381d
commit
a1d3c59af7
|
@ -5001,13 +5001,13 @@ cmdVSSratio6 = "E\x99\x06"
|
|||
MAPdotGauge = MAPdot, "MAP DOT", "kPa/s", 0, 1000, -1, -1, 2560, 2560, 0, 0
|
||||
|
||||
#if CELSIUS
|
||||
cltGauge = coolant, "Coolant Temp", "TEMP", -40, 215, -15, 0, 95, 105, 0, 0
|
||||
iatGauge = iat, "Inlet Air Temp", "TEMP", -40, 215, -15, 0, 95, 100, 0, 0
|
||||
fuelTempGauge = fuelTemp, "Fuel Temp", "TEMP", -40, 215, -15, 0, 95, 100, 0, 0
|
||||
cltGauge = coolant, "Coolant Temp", "TEMP", -40, 120, -15, 0, 95, 105, 0, 0
|
||||
iatGauge = iat, "Inlet Air Temp", "TEMP", -40, 120, -15, 0, 95, 100, 0, 0
|
||||
fuelTempGauge = fuelTemp, "Fuel Temp", "TEMP", -40, 120, -15, 0, 95, 100, 0, 0
|
||||
#else
|
||||
cltGauge = coolant, "Coolant Temp", "TEMP", -40, 215, 0, 30, 200, 220, 0, 0
|
||||
iatGauge = iat, "Inlet Air Temp", "TEMP", -40, 215, 0, 30, 200, 210, 0, 0
|
||||
fuelTempGauge = fuelTemp, "Fuel Temp", "TEMP", -40, 215, 0, 30, 200, 210, 0, 0
|
||||
cltGauge = coolant, "Coolant Temp", "TEMP", -40, 248, 0, 30, 200, 220, 0, 0
|
||||
iatGauge = iat, "Inlet Air Temp", "TEMP", -40, 248, 0, 30, 200, 210, 0, 0
|
||||
fuelTempGauge = fuelTemp, "Fuel Temp", "TEMP", -40, 248, 0, 30, 200, 210, 0, 0
|
||||
#endif
|
||||
flexGauge = flex, "Flex sensor", "%", 0, 100, -1, -1, 999, 999, 0, 0
|
||||
|
||||
|
|
Loading…
Reference in New Issue