* @file at32f435_437_clock.c
* @brief system clock config program
**************************************************************************
* Copyright notice & Disclaimer
*
* The software Board Support Package (BSP) that is made available to
* download from Artery official website is the copyrighted work of Artery.
* Artery authorizes customers to use, copy, and distribute the BSP
* software and its related documentation for the purpose of design and
* development in conjunction with Artery microcontrollers. Use of the
* software is governed by this copyright notice and the following disclaimer.
*
* THIS SOFTWARE IS PROVIDED ON "AS IS" BASIS WITHOUT WARRANTIES,
* GUARANTEES OR REPRESENTATIONS OF ANY KIND. ARTERY EXPRESSLY DISCLAIMS,
* TO THE FULLEST EXTENT PERMITTED BY LAW, ALL EXPRESS, IMPLIED OR
* STATUTORY OR OTHER WARRANTIES, GUARANTEES OR REPRESENTATIONS,
* INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY,
* FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.
*
**************************************************************************
*/
/* includes ------------------------------------------------------------------*/
#include "at32f435_437_clock.h"
/**
* @brief system clock config program
* @note the system clock is configured as follow:
* - system clock = (hext * pll_ns)/(pll_ms * pll_fr)
* - system clock source = pll (hext)
* - hext = 8000000
* - sclk = 288000000
* - ahbdiv = 1
* - ahbclk = 288000000
* - apb2div = 2
* - apb2clk = 144000000
* - apb1div = 2
* - apb1clk = 144000000
* - pll_ns = 144
* - pll_ms = 1
* - pll_fr = 4
* @param none
* @retval none
*/
void system_clock_config(void)
{
/* reset crm */
crm_reset();
/* enable pwc periph clock */
crm_periph_clock_enable(CRM_PWC_PERIPH_CLOCK, TRUE);
/* config ldo voltage */
pwc_ldo_output_voltage_set(PWC_LDO_OUTPUT_1V3);
/* set the flash clock divider */
flash_clock_divider_set(FLASH_CLOCK_DIV_3);
crm_clock_source_enable(CRM_CLOCK_SOURCE_HEXT, TRUE);
/* wait till hext is ready */
while(crm_hext_stable_wait() == ERROR)
{
}
/* config pll clock resource
common frequency config list: pll source selected hick or hext(8mhz)
_________________________________________________________________________________________________
| | | | | | | | | | |
|pll(mhz)| 288 | 252 | 216 | 192 | 180 | 144 | 108 | 72 | 36 |
|________|_________|_________|_________|_________|_________|_________|_________|_________________|
| | | | | | | | | | |
|pll_ns | 144 | 126 | 108 | 96 | 90 | 72 | 108 | 72 | 72 |
| | | | | | | | | | |
|pll_ms | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| | | | | | | | | | |
|pll_fr | FR_4 | FR_4 | FR_4 | FR_4 | FR_4 | FR_4 | FR_8 | FR_8 | FR_16|
|________|_________|_________|_________|_________|_________|_________|_________|________|________|
if pll clock source selects hext with other frequency values, or configure pll to other
frequency values, please use the at32 new clock configuration tool for configuration. */
crm_pll_config(CRM_PLL_SOURCE_HEXT, 144, 1, CRM_PLL_FR_4);
/* enable pll */
crm_clock_source_enable(CRM_CLOCK_SOURCE_PLL, TRUE);
/* wait till pll is ready */
while(crm_flag_get(CRM_PLL_STABLE_FLAG) != SET)
{
}
/* config ahbclk */
crm_ahb_div_set(CRM_AHB_DIV_1);
/* config apb2clk, the maximum frequency of APB1/APB2 clock is 144 MHz */
crm_apb2_div_set(CRM_APB2_DIV_2);
/* config apb1clk, the maximum frequency of APB1/APB2 clock is 144 MHz */
crm_apb1_div_set(CRM_APB1_DIV_2);
/* enable auto step mode */
crm_auto_step_mode_enable(TRUE);
/* select pll as system clock source */
crm_sysclk_switch(CRM_SCLK_PLL);
/* wait till pll is used as system clock source */
while(crm_sysclk_switch_status_get() != CRM_SCLK_PLL)
{
}
/* disable auto step mode */
crm_auto_step_mode_enable(FALSE);
/* update system_core_clock global variable */
system_core_clock_update();
}