tramp: re-enabled temperature support
Temps have been measured right on the STM32F031G6 located on the surface of the Tramp and seem to be quite accurate. Above 104C, it starts to trickle the power down.
This commit is contained in:
parent
47bbd46c88
commit
9681929f98
|
@ -61,6 +61,7 @@ uint8_t trampCurBand = 0;
|
|||
uint8_t trampCurChan = 0;
|
||||
uint16_t trampCurPower = 0; // Actual transmitting power
|
||||
uint16_t trampCurConfigPower = 0; // Configured transmitting power
|
||||
int16_t trampCurTemp = 0;
|
||||
uint8_t trampCurPitmode = 0;
|
||||
|
||||
uint32_t trampConfFreq = 0;
|
||||
|
@ -174,6 +175,16 @@ char trampHandleResponse(void)
|
|||
// throw bytes echoed from tx to rx in bidirectional mode away
|
||||
}
|
||||
break;
|
||||
|
||||
case 's':
|
||||
{
|
||||
uint16_t temp = (int16_t)(trampRespBuffer[6]|(trampRespBuffer[7] << 8));
|
||||
if(temp != 0) {
|
||||
trampCurTemp = temp;
|
||||
return 's';
|
||||
}
|
||||
}
|
||||
break;
|
||||
}
|
||||
|
||||
return 0;
|
||||
|
@ -323,13 +334,17 @@ void trampProcess(uint32_t currentTimeUs)
|
|||
|
||||
case TRAMP_STATUS_OFFLINE:
|
||||
case TRAMP_STATUS_ONLINE:
|
||||
|
||||
if (cmp32(currentTimeUs, lastQueryTimeUs) > 1000 * 1000) { // 1s
|
||||
|
||||
if (trampStatus == TRAMP_STATUS_OFFLINE)
|
||||
trampQueryR();
|
||||
else
|
||||
trampQueryV();
|
||||
else {
|
||||
static unsigned int cnt = 0;
|
||||
if(((cnt++) & 1) == 0)
|
||||
trampQueryV();
|
||||
else
|
||||
trampQueryS();
|
||||
}
|
||||
|
||||
lastQueryTimeUs = currentTimeUs;
|
||||
}
|
||||
|
@ -474,6 +489,8 @@ static long trampCmsConfigChan(displayPort_t *pDisp, const void *self)
|
|||
return 0;
|
||||
}
|
||||
|
||||
static OSD_INT16_t trampCmsEntTemp = { &trampCurTemp, -100, 300, 0 };
|
||||
|
||||
static const char * const trampCmsPitmodeNames[] = {
|
||||
"---", "OFF", "ON "
|
||||
};
|
||||
|
@ -560,6 +577,7 @@ static OSD_Entry trampMenuEntries[] =
|
|||
{ "CHAN", OME_TAB, trampCmsConfigChan, &trampCmsEntChan, 0 },
|
||||
{ "(FREQ)", OME_UINT16, NULL, &trampCmsEntFreqRef, DYNAMIC },
|
||||
{ "POWER", OME_TAB, NULL, &trampCmsEntPower, 0 },
|
||||
{ "T(C)", OME_INT16, NULL, &trampCmsEntTemp, DYNAMIC },
|
||||
{ "SET", OME_Submenu, cmsMenuChange, &trampCmsMenuCommence, 0 },
|
||||
|
||||
{ "BACK", OME_Back, NULL, NULL, 0 },
|
||||
|
|
Loading…
Reference in New Issue