Add virtual current sensor documentation
..and remove a couple of defines I didn't use.
This commit is contained in:
parent
a37c6ee9ee
commit
a81fad9cc2
|
@ -74,8 +74,19 @@ Enable current monitoring using the CLI command
|
|||
feature CURRENT_METER
|
||||
```
|
||||
|
||||
Configure the current meter type using the `current_meter_type` settings as per the following table.
|
||||
|
||||
| Value | Sensor Type |
|
||||
| ----- | ---------------------- |
|
||||
| 0 | None |
|
||||
| 1 | ADC/hardware sensor |
|
||||
| 2 | Virtual sensor |
|
||||
|
||||
Configure capacity using the `battery_capacity` setting, which takes a value in mAh.
|
||||
|
||||
If you're using an OSD that expects the multiwii current meter output value, then set `multiwii_current_meter_output` to `1` (this multiplies amperage sent to MSP by 10).
|
||||
|
||||
### ADC Sensor
|
||||
The current meter may need to be configured so that the value read at the ADC input matches actual current draw. Just like you need a voltmeter to correctly calibrate your voltage reading you also need an ammeter to calibrate your current sensor.
|
||||
|
||||
Use the following settings to adjust calibration.
|
||||
|
@ -83,4 +94,23 @@ Use the following settings to adjust calibration.
|
|||
`current_meter_scale`
|
||||
`current_meter_offset`
|
||||
|
||||
If you're using an OSD that expects the multiwii current meter output value, then set `multiwii_current_meter_output` to `1`.
|
||||
### Virtual Sensor
|
||||
The virtual sensor uses the throttle position to calculate as estimated current value. This is useful when a real sensor is not available. The following settings adjust the calibration.
|
||||
|
||||
| Setting | Description |
|
||||
| ----------------------------- | -------------------------------------------------------- |
|
||||
| `current_meter_scale` | The throttle scaling factor [centiamps, i.e. 1/100th A] |
|
||||
| `current_meter_offset` | The current at zero throttle [centiamps, i.e. 1/100th A] |
|
||||
|
||||
If you know your current at zero throttle (Imin) and maximum throttle(Imax) you can calculate the scaling factors using the following formulas where Tmax is maximum throttle offset (i.e. for `max_throttle` = 1850, Tmax = 1850 - 1000 = 850):
|
||||
```
|
||||
current_meter_scale = (Imax - Imin) * 100000 / (Tmax + (Tmax * Tmax / 50))
|
||||
current_meter_offset = Imin * 100
|
||||
```
|
||||
e.g. For a maximum current of 34.2 A and minimum current of 2.8 A with `max_throttle` = 1850
|
||||
```
|
||||
current_meter_scale = (Imax - Imin) * 100000 / (Tmax + (Tmax * Tmax / 50))
|
||||
= (34.2 - 2.8) * 100000 / (850 + (850 * 850 / 50))
|
||||
= 205
|
||||
current_meter_offset = Imin * 100 = 280
|
||||
```
|
||||
|
|
|
@ -20,8 +20,6 @@
|
|||
#define VBAT_SCALE_DEFAULT 110
|
||||
#define VBAT_SCALE_MIN 0
|
||||
#define VBAT_SCALE_MAX 255
|
||||
#define VIRTUAL_CURRENT_MIN 0
|
||||
#define VIRTUAL_CURRENT_MAX 0xffff
|
||||
|
||||
typedef enum {
|
||||
CURRENT_SENSOR_NONE = 0,
|
||||
|
|
Loading…