Merge pull request #9983 from haslinghuis/Change-Serial.MD
Add serial port identifier and serial port function table
This commit is contained in:
commit
f6b1c6a539
|
@ -65,6 +65,50 @@ The `serial` CLI command takes 6 arguments.
|
|||
1. Telemetry baud rate (auto baud allowed)
|
||||
1. Blackbox baud rate
|
||||
|
||||
### Serial Port Identifier
|
||||
|
||||
| Identifier | Value |
|
||||
| --- | ---: |
|
||||
| SERIAL_PORT_NONE | -1 |
|
||||
| SERIAL_PORT_USART1 | 0 |
|
||||
| SERIAL_PORT_USART2 | 1 |
|
||||
| SERIAL_PORT_USART3 | 2 |
|
||||
| SERIAL_PORT_UART4 | 3 |
|
||||
| SERIAL_PORT_UART5 | 4 |
|
||||
| SERIAL_PORT_USART6 | 5 |
|
||||
| SERIAL_PORT_USART7 | 6 |
|
||||
| SERIAL_PORT_USART8 | 7 |
|
||||
| SERIAL_PORT_LPUART1 | 8 |
|
||||
| SERIAL_PORT_USB_VCP | 20 |
|
||||
| SERIAL_PORT_SOFTSERIAL1 | 30 |
|
||||
| SERIAL_PORT_SOFTSERIAL2 | 31 |
|
||||
| SERIAL_PORT_IDENTIFIER_MAX | 31 |
|
||||
|
||||
|
||||
|
||||
### Serial Port Function
|
||||
|
||||
| Function | Value |
|
||||
| --- | ---: |
|
||||
| FUNCTION_NONE | 0 |
|
||||
| FUNCTION_MSP | 1 |
|
||||
| FUNCTION_GPS | 2 |
|
||||
| FUNCTION_TELEMETRY_FRSKY_HUB | 4 |
|
||||
| FUNCTION_TELEMETRY_HOTT | 8 |
|
||||
| FUNCTION_TELEMETRY_LTM | 16 |
|
||||
| FUNCTION_TELEMETRY_SMARTPORT | 32 |
|
||||
| FUNCTION_RX_SERIAL | 64 |
|
||||
| FUNCTION_BLACKBOX | 128 |
|
||||
| FUNCTION_TELEMETRY_MAVLINK | 512 |
|
||||
| FUNCTION_ESC_SENSOR | 1024 |
|
||||
| FUNCTION_VTX_SMARTAUDIO | 2048 |
|
||||
| FUNCTION_TELEMETRY_IBUS | 4096 |
|
||||
| FUNCTION_VTX_TRAMP | 8192 |
|
||||
| FUNCTION_RCDEVICE | 16384 |
|
||||
| FUNCTION_LIDAR_TF | 32768 |
|
||||
| FUNCTION_FRSKY_OSD | 65536 |
|
||||
|
||||
|
||||
|
||||
### Baud Rates
|
||||
|
||||
|
|