#define DIAG_REG_RD 0x78 // Read Diagnostics Register
|
||||
#define INIT_REG2_RD 0x7E // Read Initialization Register 2
|
||||
|
||||
/**********************************************************************************
|
||||
INIT_REG1 - CJ125 Initialization Register 1
|
||||
00x000x0
|
||||
||||||||---- VL - Pump Current Sense Amplifier - 0 = x8, 1 = x17
|
||||
If VL is set to "0" the amplification of Ip is 8.
|
||||
If VL is "1" the amplification is 17. The higher
|
||||
amplification is needed for a better resolution
|
||||
at Lambda > 1, amplification 8 for Lambda < 1.
|
||||
Note: It seems to make no difference, always set to 1.
|
||||
|||||||----- Unused
|
||||
||||||------ LA - Pump Current Sense Amplifier - 0 = measurement, 1 = calibration
|
||||
If LA is "0" the measurement mode for Ip is active.
|
||||
The current pump current is displayed on Ua. If LA is
|
||||
set to "1" the calibration mode is active. The shown
|
||||
voltage on Ua must been subtracted from the later measurement.
|
||||
|||||------- Undocumented Bit - Note: CJ125 only seems to work when set to 1.
|
||||
||||-------- RA - Measurement Current for Ri - 0 = measurement, 1 = calibration
|
||||
If RA is "0" the measurement mode for Ri is active and
|
||||
the current resistance of the probe is "displayed" on Ur.
|
||||
If RA is "1" the calibration mode is active. You get the
|
||||
optimal voltage for the inner resistance of the probe on Ur.
|
||||
|||--------- Unused
|
||||
||---------- PA - Pump Current Control - Set to 0 to be active
|
||||
|----------- ENABLE/HOLD - Must be set to 1 to enable
|
||||
***********************************************************************************/
|
||||
|
||||
#define CJ125_INIT1_NORMAL_8 0x88 // 0b10001000 (Normal mode, Amplification 8)
|
||||
#define CJ125_INIT1_NORMAL_17 0x89 // 0b10001001 (Normal mode, Amplification 17)
|
||||
#define CJ125_INIT1_CALBRT 0x9D // 0b10011101 (Calibration mode, LA=1, RA=1)
|
||||
|
|