Custom Auto-generated Configs

[no ci]
This commit is contained in:
GitHub git update Action 2024-07-24 21:14:48 +00:00
parent 760d6120b2
commit b1784c92e6
3 changed files with 18 additions and 17 deletions

View File

@ -1291,7 +1291,7 @@
#define show_Proteus_presets false
#define show_test_presets false
#define show_vvt_output_pin true
#define SIGNATURE_HASH 2228145623
#define SIGNATURE_HASH 560579054
#define SIMULATOR_TUNE_BIN_FILE_NAME "generated/simulator_tune_image.bin"
#define SIMULATOR_TUNE_BIN_FILE_NAME_PREFIX "generated/simulator_tune_image"
#define SIMULATOR_TUNE_BIN_FILE_NAME_SUFFIX ".bin"
@ -1626,6 +1626,7 @@
#define ts_show_egt true
#define ts_show_etb true
#define ts_show_etb_bias_curve true
#define ts_show_etb_extra_monitoring false
#define ts_show_etb_pins true
#define ts_show_exhaust_vvt true
#define ts_show_experimental true
@ -1709,9 +1710,10 @@
#define ts_show_vr_threshold_all false
#define ts_show_vr_threshold_pins true
#define ts_show_vvt_output true
#define ts_show_vvt_output_pin true
#define ts_show_wbo_canbus_index true
#define ts_show_wbo_canbus_set_index true
#define TS_SIGNATURE "rusEFI master.2024.07.22.paralela.2228145623"
#define TS_SIGNATURE "rusEFI master.2024.07.24.paralela.560579054"
#define TS_SIMULATE_CAN '>'
#define TS_SIMULATE_CAN_char >
#define TS_SINGLE_WRITE_COMMAND 'W'

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool config_definition-all.jar based on gen_config.sh by SignatureConsumer
//
#define SIGNATURE_HASH 2228145623
#define TS_SIGNATURE "rusEFI master.2024.07.22.paralela.2228145623"
#define SIGNATURE_HASH 560579054
#define TS_SIGNATURE "rusEFI master.2024.07.24.paralela.560579054"

View File

@ -38,12 +38,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI master.2024.07.22.paralela.2228145623"
signature = "rusEFI master.2024.07.24.paralela.560579054"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmware version for title bar.
signature= "rusEFI master.2024.07.22.paralela.2228145623" ; signature is expected to be 7 or more characters.
signature= "rusEFI master.2024.07.24.paralela.560579054" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -100,7 +100,7 @@ enable2ndByteCanID = false
#define adc_channel_e_list="NONE","TPS (A0)","MAP (A1)","CLT (A2)","INVALID","INVALID","TPS (A5)","INVALID","INVALID","O2-2 (B0)","INVALID","INVALID","BattV (C1)","IAT (C2)","O2-1 (C3)","PPS1 (C4)","PPS2 (C5)"
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool config_definition-all.jar based on (unknown script) integration/rusefi_config.txt Mon Jul 22 21:12:22 UTC 2024
; this section was generated automatically by rusEFI tool config_definition-all.jar based on (unknown script) integration/rusefi_config.txt Wed Jul 24 21:12:26 UTC 2024
pageSize = 24900
page = 1
@ -7206,14 +7206,14 @@ dialog = lambda_monitorDialog, "lambda_monitor"
field = "Gap #5 to", triggerGapOverrideTo5, { overrideTriggerGaps == 1 && gapTrackingLengthOverride >= 5 }
field = "Override well known VVT gaps", overrideVvtTriggerGaps
field = gapVvtTrackingLengthOverride, gapVvtTrackingLengthOverride, { overrideVvtTriggerGaps == 1 }
field = "First VVT gap from", triggerVVTGapOverrideFrom1
field = "First VVT gap to", triggerVVTGapOverrideTo1
field = "Second VVT gap from", triggerVVTGapOverrideFrom2
field = "Second VVT gap to", triggerVVTGapOverrideTo2
field = "VVT gap #3 from", triggerVVTGapOverrideFrom3
field = "VVT gap #3 to", triggerVVTGapOverrideTo3
field = "VVT gap #4 from", triggerVVTGapOverrideFrom4
field = "VVT gap #4 to", triggerVVTGapOverrideTo4
field = "First VVT gap from", triggerVVTGapOverrideFrom1, { overrideVvtTriggerGaps == 1 }
field = "First VVT gap to", triggerVVTGapOverrideTo1, { overrideVvtTriggerGaps == 1 }
field = "Second VVT gap from", triggerVVTGapOverrideFrom2, { overrideVvtTriggerGaps == 1 && gapVvtTrackingLengthOverride >= 2 }
field = "Second VVT gap to", triggerVVTGapOverrideTo2, { overrideVvtTriggerGaps == 1 && gapVvtTrackingLengthOverride >= 2 }
field = "VVT gap #3 from", triggerVVTGapOverrideFrom3, { overrideVvtTriggerGaps == 1 && gapVvtTrackingLengthOverride >= 3 }
field = "VVT gap #3 to", triggerVVTGapOverrideTo3, { overrideVvtTriggerGaps == 1 && gapVvtTrackingLengthOverride >= 3 }
field = "VVT gap #4 from", triggerVVTGapOverrideFrom4 { overrideVvtTriggerGaps == 1 && gapVvtTrackingLengthOverride >= 4 }
field = "VVT gap #4 to", triggerVVTGapOverrideTo4 { overrideVvtTriggerGaps == 1 && gapVvtTrackingLengthOverride >= 4 }
dialog = trigger_advanced, "Advanced Trigger"
field = "Require cam/VVT sync for ignition", isPhaseSyncRequiredForIgnition
@ -8661,6 +8661,7 @@ dialog = lambda_monitorDialog, "lambda_monitor"
dialog = vvtPidDialog0, "Configuration"
field = "Activation Delay", vvtActivationDelayMs
field = "Do not control below RPM", vvtControlMinRpm
field = "VVT solenoid bank 1 intake", vvtPins1
field = "VVT solenoid bank 1 exhaust", vvtPins2
field = "VVT solenoid bank 2 intake", vvtPins3
field = "VVT solenoid bank 2 exhaust", vvtPins4
@ -9285,8 +9286,6 @@ dialog = tcuControls, "Transmission Settings"
field = "Maximum ETB position", etbMaximumPosition
; field = "Jam detection integrator max", etbJamIntegratorLimit
; field = "Jam detection timeout period", etbJamTimeout
field = "Duty Averaging Length", etbExpAverageLength
field = "Rate of change Averaging Length", etbRocExpAverageLength
; we need the term about stepper idle in here, because there's a bug in TS that you can't have different visibility
; criteria for the same panel when used in multiple places
; todo: report bug to TS?