mirror of https://github.com/rusefi/openblt.git
- reverted the change in the Peak CAN interface dll (for bus off recovery) as it does not work reliably.
git-svn-id: https://svn.code.sf.net/p/openblt/code/trunk@100 5dc33758-31d5-4daf-9ae8-b24bf3d40d73
This commit is contained in:
parent
706e582e63
commit
6844a08742
|
@ -471,19 +471,8 @@ begin
|
|||
// submit the transmit request
|
||||
if CAN_Write(msg) <> CAN_ERR_OK then
|
||||
begin
|
||||
// the Peak CAN interface has a bug because if it is the only node on the bus
|
||||
// transmitting a message, it will actually go in bus off, which is not allowed
|
||||
// according to the CAN protocol. this scenario can be resolved by re-initializing
|
||||
// the CAN interface.
|
||||
if (CAN_Status and CAN_ERR_BUSOFF) = CAN_ERR_BUSOFF then
|
||||
begin
|
||||
Disconnect;
|
||||
if not Connect then
|
||||
begin
|
||||
Result := False;
|
||||
exit;
|
||||
end;
|
||||
end;
|
||||
Result := False;
|
||||
exit;
|
||||
end;
|
||||
|
||||
//---------------- process transmission confirmation --------------------------
|
||||
|
|
Binary file not shown.