fix 36-2 trigger params (#4138)

* fix gap params

* changelog was wrong too

* typo

* binary log knock count and retard

* Revert "binary log knock count and retard"

This reverts commit 48b29d24d72331065a9f648ef5bfe845d03575d6.
This commit is contained in:
Matthew Kennedy 2022-05-04 21:41:26 -07:00 committed by GitHub
parent 46acfb198c
commit 045cbcbff1
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
2 changed files with 3 additions and 4 deletions

View File

@ -28,7 +28,7 @@ Release template (copy/paste this for new release):
- ETB low limit is now configurable #4119
### Fixed
- 36-1 trigger gaps #4132
- Make 36-2 trigger sync parameters more generous #4132
## April 20202 Release - "Day 58"

View File

@ -637,7 +637,8 @@ void TriggerWaveform::initializeTriggerWaveform(operation_mode_e triggerOperatio
case TT_TOOTHED_WHEEL_36_2:
setToothedWheelConfiguration(this, 36, 2, triggerOperationMode);
setSecondTriggerSynchronizationGap(1); // this gap is not required to synch on perfect signal but is needed to handle to reject cranking transition noise
setTriggerSynchronizationGap3(/*gapIndex*/0, /*from*/1.6, 3.5);
setTriggerSynchronizationGap3(/*gapIndex*/1, /*from*/0.7, 1.3); // second gap is not required to synch on perfect signal but is needed to handle to reject cranking transition noise
break;
case TT_60_2_VW:
@ -646,8 +647,6 @@ void TriggerWaveform::initializeTriggerWaveform(operation_mode_e triggerOperatio
case TT_TOOTHED_WHEEL_36_1:
setToothedWheelConfiguration(this, 36, 1, triggerOperationMode);
setTriggerSynchronizationGap3(/*gapIndex*/0, /*from*/1.9, 3.5);
setTriggerSynchronizationGap3(/*gapIndex*/1, /*from*/0.7, 1.3); // second gap is not required to synch on perfect signal but is needed to handle to reject cranking transition noise
break;
case TT_VVT_BOSCH_QUICK_START: