Auto-generated configs and docs

This commit is contained in:
GitHub build-firmware Action 2022-01-18 23:22:56 +00:00
parent 6859c3bcbe
commit 079a26ead8
4 changed files with 10 additions and 10 deletions

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh null
//
#define SIGNATURE_HASH 3629759027
#define TS_SIGNATURE "rusEFI 2022.01.18.proteus_f4.3629759027"
#define SIGNATURE_HASH 3471216924
#define TS_SIGNATURE "rusEFI 2022.01.18.proteus_f4.3471216924"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh null
//
#define SIGNATURE_HASH 3629759027
#define TS_SIGNATURE "rusEFI 2022.01.18.proteus_f7.3629759027"
#define SIGNATURE_HASH 3471216924
#define TS_SIGNATURE "rusEFI 2022.01.18.proteus_f7.3471216924"

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2022.01.18.proteus_f4.3629759027"
signature = "rusEFI 2022.01.18.proteus_f4.3471216924"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2022.01.18.proteus_f4.3629759027" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2022.01.18.proteus_f4.3471216924" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -84,7 +84,7 @@ enable2ndByteCanID = false
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) integration/rusefi_config.txt Tue Jan 18 05:50:04 UTC 2022
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) integration/rusefi_config.txt Tue Jan 18 23:21:02 UTC 2022
pageSize = 20996
page = 1

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2022.01.18.proteus_f7.3629759027"
signature = "rusEFI 2022.01.18.proteus_f7.3471216924"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2022.01.18.proteus_f7.3629759027" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2022.01.18.proteus_f7.3471216924" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -84,7 +84,7 @@ enable2ndByteCanID = false
; name = scalar, type, offset, units, scale, translate, lo, hi, digits
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) integration/rusefi_config.txt Tue Jan 18 05:50:02 UTC 2022
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on (unknown script) integration/rusefi_config.txt Tue Jan 18 23:21:00 UTC 2022
pageSize = 20996
page = 1