Auto-generated configs and docs

This commit is contained in:
GitHub build-firmware Action 2021-11-14 16:51:07 +00:00
parent e01aa6139b
commit 391218b562
57 changed files with 656 additions and 289 deletions

View File

@ -1,4 +1,4 @@
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:42 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:41 UTC 2021
// by class com.rusefi.output.CHeaderConsumer
// begin
#pragma once
@ -3712,10 +3712,14 @@ struct engine_configuration_s {
*/
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
/**
units
* offset 3628
*/
uint8_t unused3328[236];
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
/**
units
* offset 3756
*/
uint8_t unused3328[108];
/**
Min tCharge Coeff.
* offset 3864
@ -4541,4 +4545,4 @@ struct persistent_config_s {
};
// end
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:42 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:41 UTC 2021

View File

@ -1773,6 +1773,14 @@
#define scriptSetting6_offset 884
#define scriptSetting7_offset 888
#define scriptSetting8_offset 892
#define scriptSettingName1_offset 3628
#define scriptSettingName2_offset 3644
#define scriptSettingName3_offset 3660
#define scriptSettingName4_offset 3676
#define scriptSettingName5_offset 3692
#define scriptSettingName6_offset 3708
#define scriptSettingName7_offset 3724
#define scriptSettingName8_offset 3740
#define scriptTable1_offset 19296
#define scriptTable1LoadBins_offset 19552
#define scriptTable1RpmBins_offset 19584
@ -1818,7 +1826,7 @@
#define show_test_presets true
#define showHumanReadableWarning_offset 976
#define showSdCardWarning_offset 76
#define SIGNATURE_HASH 2319440833
#define SIGNATURE_HASH 1575955825
#define silentTriggerError_offset 1464
#define slowAdcAlpha_offset 2088
#define sparkDwellRpmBins_offset 332
@ -2337,7 +2345,7 @@
#define ts_show_spi true
#define ts_show_trigger_comparator false
#define ts_show_tunerstudio_port true
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.2319440833"
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.1575955825"
#define TS_SINGLE_WRITE_COMMAND 'W'
#define TS_SINGLE_WRITE_COMMAND_char W
#define TS_TEST_COMMAND 't'
@ -2376,7 +2384,7 @@
#define unused2508_offset 2511
#define unused2536_offset 2539
#define unused3103_offset 3103
#define unused3328_offset 3628
#define unused3328_offset 3756
#define unused3942_offset 3992
#define unused3988_offset 3988
#define unused4028_offset 4028

View File

@ -1,4 +1,4 @@
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:40 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:38 UTC 2021
// by class com.rusefi.output.CHeaderConsumer
// begin
#pragma once
@ -3706,10 +3706,14 @@ struct engine_configuration_s {
*/
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
/**
units
* offset 3600
*/
uint8_t unused3328[236];
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
/**
units
* offset 3728
*/
uint8_t unused3328[108];
/**
Min tCharge Coeff.
* offset 3836
@ -4535,4 +4539,4 @@ struct persistent_config_s {
};
// end
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:40 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:38 UTC 2021

View File

@ -1758,6 +1758,14 @@
#define scriptSetting6_offset 884
#define scriptSetting7_offset 888
#define scriptSetting8_offset 892
#define scriptSettingName1_offset 3600
#define scriptSettingName2_offset 3616
#define scriptSettingName3_offset 3632
#define scriptSettingName4_offset 3648
#define scriptSettingName5_offset 3664
#define scriptSettingName6_offset 3680
#define scriptSettingName7_offset 3696
#define scriptSettingName8_offset 3712
#define scriptTable1_offset 19268
#define scriptTable1LoadBins_offset 19524
#define scriptTable1RpmBins_offset 19556
@ -1803,7 +1811,7 @@
#define show_test_presets true
#define showHumanReadableWarning_offset 976
#define showSdCardWarning_offset 76
#define SIGNATURE_HASH 1973032765
#define SIGNATURE_HASH 2722816397
#define silentTriggerError_offset 1464
#define slowAdcAlpha_offset 2088
#define sparkDwellRpmBins_offset 332
@ -2322,7 +2330,7 @@
#define ts_show_spi true
#define ts_show_trigger_comparator true
#define ts_show_tunerstudio_port true
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.1973032765"
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.2722816397"
#define TS_SINGLE_WRITE_COMMAND 'W'
#define TS_SINGLE_WRITE_COMMAND_char W
#define TS_TEST_COMMAND 't'
@ -2361,7 +2369,7 @@
#define unused2508_offset 2503
#define unused2536_offset 2531
#define unused3103_offset 3075
#define unused3328_offset 3600
#define unused3328_offset 3728
#define unused3942_offset 3964
#define unused3988_offset 3960
#define unused4028_offset 4000

View File

@ -1,4 +1,4 @@
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:45 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:44 UTC 2021
// by class com.rusefi.output.CHeaderConsumer
// begin
#pragma once
@ -3712,10 +3712,14 @@ struct engine_configuration_s {
*/
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
/**
units
* offset 3628
*/
uint8_t unused3328[236];
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
/**
units
* offset 3756
*/
uint8_t unused3328[108];
/**
Min tCharge Coeff.
* offset 3864
@ -4541,4 +4545,4 @@ struct persistent_config_s {
};
// end
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:45 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:44 UTC 2021

View File

@ -1785,6 +1785,14 @@
#define scriptSetting6_offset 884
#define scriptSetting7_offset 888
#define scriptSetting8_offset 892
#define scriptSettingName1_offset 3628
#define scriptSettingName2_offset 3644
#define scriptSettingName3_offset 3660
#define scriptSettingName4_offset 3676
#define scriptSettingName5_offset 3692
#define scriptSettingName6_offset 3708
#define scriptSettingName7_offset 3724
#define scriptSettingName8_offset 3740
#define scriptTable1_offset 19296
#define scriptTable1LoadBins_offset 19552
#define scriptTable1RpmBins_offset 19584
@ -1831,7 +1839,7 @@
#define show_test_presets false
#define showHumanReadableWarning_offset 976
#define showSdCardWarning_offset 76
#define SIGNATURE_HASH 1936730669
#define SIGNATURE_HASH 2762005661
#define silentTriggerError_offset 1464
#define slowAdcAlpha_offset 2088
#define sparkDwellRpmBins_offset 332
@ -2350,7 +2358,7 @@
#define ts_show_spi true
#define ts_show_trigger_comparator false
#define ts_show_tunerstudio_port false
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.1936730669"
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.2762005661"
#define TS_SINGLE_WRITE_COMMAND 'W'
#define TS_SINGLE_WRITE_COMMAND_char W
#define TS_TEST_COMMAND 't'
@ -2389,7 +2397,7 @@
#define unused2508_offset 2511
#define unused2536_offset 2539
#define unused3103_offset 3103
#define unused3328_offset 3628
#define unused3328_offset 3756
#define unused3942_offset 3992
#define unused3988_offset 3988
#define unused4028_offset 4028

View File

@ -1,4 +1,4 @@
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
// by class com.rusefi.output.CHeaderConsumer
// begin
#pragma once
@ -3712,10 +3712,14 @@ struct engine_configuration_s {
*/
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
/**
units
* offset 3628
*/
uint8_t unused3328[236];
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
/**
units
* offset 3756
*/
uint8_t unused3328[108];
/**
Min tCharge Coeff.
* offset 3864
@ -4541,4 +4545,4 @@ struct persistent_config_s {
};
// end
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021

View File

@ -1,3 +1,3 @@
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
// by class com.rusefi.output.FileFsioSettingsConsumer

View File

@ -1,3 +1,3 @@
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
// by class com.rusefi.output.FileFsioSettingsConsumer

View File

@ -1,3 +1,3 @@
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
// by class com.rusefi.output.FileFsioSettingsConsumer

View File

@ -1,3 +1,3 @@
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
// by class com.rusefi.output.FileFsioSettingsConsumer

View File

@ -1773,6 +1773,14 @@
#define scriptSetting6_offset 884
#define scriptSetting7_offset 888
#define scriptSetting8_offset 892
#define scriptSettingName1_offset 3628
#define scriptSettingName2_offset 3644
#define scriptSettingName3_offset 3660
#define scriptSettingName4_offset 3676
#define scriptSettingName5_offset 3692
#define scriptSettingName6_offset 3708
#define scriptSettingName7_offset 3724
#define scriptSettingName8_offset 3740
#define scriptTable1_offset 19296
#define scriptTable1LoadBins_offset 19552
#define scriptTable1RpmBins_offset 19584
@ -1818,7 +1826,7 @@
#define show_test_presets true
#define showHumanReadableWarning_offset 976
#define showSdCardWarning_offset 76
#define SIGNATURE_HASH 2966043773
#define SIGNATURE_HASH 1729809101
#define silentTriggerError_offset 1464
#define slowAdcAlpha_offset 2088
#define sparkDwellRpmBins_offset 332
@ -2337,7 +2345,7 @@
#define ts_show_spi true
#define ts_show_trigger_comparator false
#define ts_show_tunerstudio_port true
#define TS_SIGNATURE "rusEFI 2021.11.14.all.2966043773"
#define TS_SIGNATURE "rusEFI 2021.11.14.all.1729809101"
#define TS_SINGLE_WRITE_COMMAND 'W'
#define TS_SINGLE_WRITE_COMMAND_char W
#define TS_TEST_COMMAND 't'
@ -2376,7 +2384,7 @@
#define unused2508_offset 2511
#define unused2536_offset 2539
#define unused3103_offset 3103
#define unused3328_offset 3628
#define unused3328_offset 3756
#define unused3942_offset 3992
#define unused3988_offset 3988
#define unused4028_offset 4028

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 2966043773
#define TS_SIGNATURE "rusEFI 2021.11.14.all.2966043773"
#define SIGNATURE_HASH 1729809101
#define TS_SIGNATURE "rusEFI 2021.11.14.all.1729809101"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 2885732698
#define TS_SIGNATURE "rusEFI 2021.11.14.atlas.2885732698"
#define SIGNATURE_HASH 2077245418
#define TS_SIGNATURE "rusEFI 2021.11.14.atlas.2077245418"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 2966043773
#define TS_SIGNATURE "rusEFI 2021.11.14.f429-discovery.2966043773"
#define SIGNATURE_HASH 1729809101
#define TS_SIGNATURE "rusEFI 2021.11.14.f429-discovery.1729809101"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 3405277588
#define TS_SIGNATURE "rusEFI 2021.11.14.frankenso_na6.3405277588"
#define SIGNATURE_HASH 489201444
#define TS_SIGNATURE "rusEFI 2021.11.14.frankenso_na6.489201444"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 353897716
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen-nb1.353897716"
#define SIGNATURE_HASH 3267951172
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen-nb1.3267951172"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 189685468
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121nissan.189685468"
#define SIGNATURE_HASH 3701385324
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121nissan.3701385324"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 4016642167
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121vag.4016642167"
#define SIGNATURE_HASH 951709383
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121vag.951709383"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 705451994
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen128.705451994"
#define SIGNATURE_HASH 4259094890
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen128.4259094890"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 2451455707
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen154hyundai.2451455707"
#define SIGNATURE_HASH 1171179627
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen154hyundai.1171179627"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 1148697549
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen72.1148697549"
#define SIGNATURE_HASH 2477215101
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen72.2477215101"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 285912354
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen88bmw.285912354"
#define SIGNATURE_HASH 3336199058
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen88bmw.3336199058"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 3338107605
#define TS_SIGNATURE "rusEFI 2021.11.14.hellenNA6.3338107605"
#define SIGNATURE_HASH 287804517
#define TS_SIGNATURE "rusEFI 2021.11.14.hellenNA6.287804517"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt
//
#define SIGNATURE_HASH 2319440833
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.2319440833"
#define SIGNATURE_HASH 1575955825
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.1575955825"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt
//
#define SIGNATURE_HASH 1973032765
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.1973032765"
#define SIGNATURE_HASH 2722816397
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.2722816397"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 999380956
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f4.999380956"
#define SIGNATURE_HASH 3963724140
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f4.3963724140"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 999380956
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f7.999380956"
#define SIGNATURE_HASH 3963724140
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f7.3963724140"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 3760252315
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_405.3760252315"
#define SIGNATURE_HASH 938480427
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_405.938480427"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 3760252315
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_469.3760252315"
#define SIGNATURE_HASH 938480427
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_469.938480427"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 464869372
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f4.464869372"
#define SIGNATURE_HASH 3429212492
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f4.3429212492"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 464869372
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f7.464869372"
#define SIGNATURE_HASH 3429212492
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f7.3429212492"

View File

@ -2,5 +2,5 @@
// was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt
//
#define SIGNATURE_HASH 1936730669
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.1936730669"
#define SIGNATURE_HASH 2762005661
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.2762005661"

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.all.2966043773"
signature = "rusEFI 2021.11.14.all.1729809101"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.all.2966043773" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.all.1729809101" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.atlas.2885732698"
signature = "rusEFI 2021.11.14.atlas.2077245418"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.atlas.2885732698" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.atlas.2077245418" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:34 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:32 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5150,12 +5158,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.f429-discovery.2966043773"
signature = "rusEFI 2021.11.14.f429-discovery.1729809101"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.f429-discovery.2966043773" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.f429-discovery.1729809101" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:46 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:39 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.frankenso_na6.3405277588"
signature = "rusEFI 2021.11.14.frankenso_na6.489201444"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.frankenso_na6.3405277588" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.frankenso_na6.489201444" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:20 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:15 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen-nb1.353897716"
signature = "rusEFI 2021.11.14.hellen-nb1.3267951172"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen-nb1.353897716" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen-nb1.3267951172" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:08 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:03 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5135,12 +5143,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen121nissan.189685468"
signature = "rusEFI 2021.11.14.hellen121nissan.3701385324"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen121nissan.189685468" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen121nissan.3701385324" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:56 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:49 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen121vag.4016642167"
signature = "rusEFI 2021.11.14.hellen121vag.951709383"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen121vag.4016642167" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen121vag.951709383" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:52 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:46 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen128.705451994"
signature = "rusEFI 2021.11.14.hellen128.4259094890"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen128.705451994" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen128.4259094890" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:49 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:43 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen154hyundai.2451455707"
signature = "rusEFI 2021.11.14.hellen154hyundai.1171179627"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen154hyundai.2451455707" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen154hyundai.1171179627" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:59 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:53 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen72.1148697549"
signature = "rusEFI 2021.11.14.hellen72.2477215101"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen72.1148697549" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen72.2477215101" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:04 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:59 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5135,12 +5143,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen88bmw.285912354"
signature = "rusEFI 2021.11.14.hellen88bmw.3336199058"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen88bmw.285912354" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen88bmw.3336199058" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:01 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:56 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellenNA6.3338107605"
signature = "rusEFI 2021.11.14.hellenNA6.287804517"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellenNA6.3338107605" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellenNA6.287804517" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:11 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:06 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5135,12 +5143,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.hellen_cypress.2319440833"
signature = "rusEFI 2021.11.14.hellen_cypress.1575955825"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.hellen_cypress.2319440833" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.hellen_cypress.1575955825" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:42 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:41 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.kin.1973032765"
signature = "rusEFI 2021.11.14.kin.2722816397"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.kin.1973032765" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.kin.2722816397" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:40 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:38 UTC 2021
pageSize = 19972
page = 1
@ -1050,7 +1050,15 @@ scriptTableName1 = string, ASCII, 3536, 16
scriptTableName2 = string, ASCII, 3552, 16
scriptTableName3 = string, ASCII, 3568, 16
scriptTableName4 = string, ASCII, 3584, 16
unused3328 = array, U08, 3600, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3600, 16
scriptSettingName2 = string, ASCII, 3616, 16
scriptSettingName3 = string, ASCII, 3632, 16
scriptSettingName4 = string, ASCII, 3648, 16
scriptSettingName5 = string, ASCII, 3664, 16
scriptSettingName6 = string, ASCII, 3680, 16
scriptSettingName7 = string, ASCII, 3696, 16
scriptSettingName8 = string, ASCII, 3712, 16
unused3328 = array, U08, 3728, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3836, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3840, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3844, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5125,12 +5133,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.mre_f4.999380956"
signature = "rusEFI 2021.11.14.mre_f4.3963724140"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.mre_f4.999380956" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.mre_f4.3963724140" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:17 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:12 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5133,12 +5141,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.mre_f7.999380956"
signature = "rusEFI 2021.11.14.mre_f7.3963724140"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.mre_f7.999380956" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.mre_f7.3963724140" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:14 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:09 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5133,12 +5141,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.prometheus_405.3760252315"
signature = "rusEFI 2021.11.14.prometheus_405.938480427"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.prometheus_405.3760252315" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.prometheus_405.938480427" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:26 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:22 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5153,12 +5161,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.prometheus_469.3760252315"
signature = "rusEFI 2021.11.14.prometheus_469.938480427"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.prometheus_469.3760252315" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.prometheus_469.938480427" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:23 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:19 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5153,12 +5161,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.proteus_f4.464869372"
signature = "rusEFI 2021.11.14.proteus_f4.3429212492"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.proteus_f4.464869372" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.proteus_f4.3429212492" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:31 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:28 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5126,12 +5134,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.proteus_f7.464869372"
signature = "rusEFI 2021.11.14.proteus_f7.3429212492"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.proteus_f7.464869372" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.proteus_f7.3429212492" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:29 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:25 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5126,12 +5134,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -32,12 +32,12 @@ enable2ndByteCanID = false
[MegaTune]
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
signature = "rusEFI 2021.11.14.subaru_eg33_f7.1936730669"
signature = "rusEFI 2021.11.14.subaru_eg33_f7.2762005661"
[TunerStudio]
queryCommand = "S"
versionInfo = "V" ; firmwave version for title bar.
signature = "rusEFI 2021.11.14.subaru_eg33_f7.1936730669" ; signature is expected to be 7 or more characters.
signature = "rusEFI 2021.11.14.subaru_eg33_f7.2762005661" ; signature is expected to be 7 or more characters.
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
useLegacyFTempUnits = false
@ -85,7 +85,7 @@ enable2ndByteCanID = false
; see PAGE_0_SIZE in C source code
; CONFIG_DEFINITION_START
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:45 UTC 2021
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:44 UTC 2021
pageSize = 20000
page = 1
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
scriptTableName2 = string, ASCII, 3580, 16
scriptTableName3 = string, ASCII, 3596, 16
scriptTableName4 = string, ASCII, 3612, 16
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
scriptSettingName1 = string, ASCII, 3628, 16
scriptSettingName2 = string, ASCII, 3644, 16
scriptSettingName3 = string, ASCII, 3660, 16
scriptSettingName4 = string, ASCII, 3676, 16
scriptSettingName5 = string, ASCII, 3692, 16
scriptSettingName6 = string, ASCII, 3708, 16
scriptSettingName7 = string, ASCII, 3724, 16
scriptSettingName8 = string, ASCII, 3740, 16
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
@ -5149,12 +5157,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
field = "!Use rusEFI console for Lua script editing"
field = "Set number is not associated with the output number."
field = "Set number, only the cell number with some numbers."
field = "set #1", scriptSetting1
field = "set #2", scriptSetting2
field = "set #3", scriptSetting3
field = "set #4", scriptSetting4
field = "set #5", scriptSetting5
field = "set #6", scriptSetting6
field = "Name #1", scriptSettingName1
field = "Setting #1", scriptSetting1
field = "Name #2", scriptSettingName2
field = "Setting #2", scriptSetting2
field = "Name #3", scriptSettingName3
field = "Setting #3", scriptSetting3
field = "Name #4", scriptSettingName4
field = "Setting #4", scriptSetting4
field = "Name #5", scriptSettingName5
field = "Setting #5", scriptSetting5
field = "Name #6", scriptSettingName6
field = "Setting #6", scriptSetting6
dialog = scriptSettingDialog, "Script Settings", border
panel = scriptSetting, East

View File

@ -1,6 +1,6 @@
package com.rusefi.config.generated;
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
// by class com.rusefi.output.FileJavaFieldsConsumer
import com.rusefi.config.*;
@ -1705,6 +1705,14 @@ public class Fields {
public static final int scriptSetting6_offset = 884;
public static final int scriptSetting7_offset = 888;
public static final int scriptSetting8_offset = 892;
public static final int scriptSettingName1_offset = 3628;
public static final int scriptSettingName2_offset = 3644;
public static final int scriptSettingName3_offset = 3660;
public static final int scriptSettingName4_offset = 3676;
public static final int scriptSettingName5_offset = 3692;
public static final int scriptSettingName6_offset = 3708;
public static final int scriptSettingName7_offset = 3724;
public static final int scriptSettingName8_offset = 3740;
public static final int scriptTable1_offset = 19296;
public static final int scriptTable1LoadBins_offset = 19552;
public static final int scriptTable1RpmBins_offset = 19584;
@ -1745,6 +1753,7 @@ public class Fields {
public static final int servoOutputPins8_offset = 3147;
public static final int showHumanReadableWarning_offset = 976;
public static final int showSdCardWarning_offset = 76;
public static final int SIGNATURE_HASH = 1729809101;
public static final int silentTriggerError_offset = 1464;
public static final int slowAdcAlpha_offset = 2088;
public static final int sparkDwellRpmBins_offset = 332;
@ -2208,7 +2217,7 @@ public class Fields {
public static final int TS_RESPONSE_UNDERRUN = 0x80;
public static final int TS_RESPONSE_UNRECOGNIZED_COMMAND = 0x83;
public static final char TS_SET_LOGGER_SWITCH = 'l';
public static final String TS_SIGNATURE = "rusEFI 2021.11.14.all.2966043773";
public static final String TS_SIGNATURE = "rusEFI 2021.11.14.all.1729809101";
public static final char TS_SINGLE_WRITE_COMMAND = 'W';
public static final char TS_TEST_COMMAND = 't';
public static final int tunerStudioSerialSpeed_offset = 728;
@ -2244,7 +2253,7 @@ public class Fields {
public static final int unused2508_offset = 2511;
public static final int unused2536_offset = 2539;
public static final int unused3103_offset = 3103;
public static final int unused3328_offset = 3628;
public static final int unused3328_offset = 3756;
public static final int unused3942_offset = 3992;
public static final int unused3988_offset = 3988;
public static final int unused4028_offset = 4028;
@ -3429,7 +3438,15 @@ public class Fields {
public static final Field SCRIPTTABLENAME2 = Field.create("SCRIPTTABLENAME2", 3580, 16, FieldType.STRING);
public static final Field SCRIPTTABLENAME3 = Field.create("SCRIPTTABLENAME3", 3596, 16, FieldType.STRING);
public static final Field SCRIPTTABLENAME4 = Field.create("SCRIPTTABLENAME4", 3612, 16, FieldType.STRING);
public static final Field UNUSED3328 = Field.create("UNUSED3328", 3628, FieldType.INT8);
public static final Field SCRIPTSETTINGNAME1 = Field.create("SCRIPTSETTINGNAME1", 3628, 16, FieldType.STRING);
public static final Field SCRIPTSETTINGNAME2 = Field.create("SCRIPTSETTINGNAME2", 3644, 16, FieldType.STRING);
public static final Field SCRIPTSETTINGNAME3 = Field.create("SCRIPTSETTINGNAME3", 3660, 16, FieldType.STRING);
public static final Field SCRIPTSETTINGNAME4 = Field.create("SCRIPTSETTINGNAME4", 3676, 16, FieldType.STRING);
public static final Field SCRIPTSETTINGNAME5 = Field.create("SCRIPTSETTINGNAME5", 3692, 16, FieldType.STRING);
public static final Field SCRIPTSETTINGNAME6 = Field.create("SCRIPTSETTINGNAME6", 3708, 16, FieldType.STRING);
public static final Field SCRIPTSETTINGNAME7 = Field.create("SCRIPTSETTINGNAME7", 3724, 16, FieldType.STRING);
public static final Field SCRIPTSETTINGNAME8 = Field.create("SCRIPTSETTINGNAME8", 3740, 16, FieldType.STRING);
public static final Field UNUSED3328 = Field.create("UNUSED3328", 3756, FieldType.INT8);
public static final Field TCHARGEAIRCOEFMIN = Field.create("TCHARGEAIRCOEFMIN", 3864, FieldType.FLOAT);
public static final Field TCHARGEAIRCOEFMAX = Field.create("TCHARGEAIRCOEFMAX", 3868, FieldType.FLOAT);
public static final Field TCHARGEAIRFLOWMAX = Field.create("TCHARGEAIRFLOWMAX", 3872, FieldType.FLOAT);
@ -4692,6 +4709,14 @@ public class Fields {
SCRIPTTABLENAME2,
SCRIPTTABLENAME3,
SCRIPTTABLENAME4,
SCRIPTSETTINGNAME1,
SCRIPTSETTINGNAME2,
SCRIPTSETTINGNAME3,
SCRIPTSETTINGNAME4,
SCRIPTSETTINGNAME5,
SCRIPTSETTINGNAME6,
SCRIPTSETTINGNAME7,
SCRIPTSETTINGNAME8,
UNUSED3328,
TCHARGEAIRCOEFMIN,
TCHARGEAIRCOEFMAX,

View File

@ -1,6 +1,6 @@
<roms>
<!-- was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh Sun Nov 14 15:51:39 UTC 2021 -->
<!-- was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh Sun Nov 14 16:49:37 UTC 2021 -->
<rom>
<romid>