diff --git a/firmware/integration/rusefi_config.txt b/firmware/integration/rusefi_config.txt index 0955e65525..c0486a97f7 100644 --- a/firmware/integration/rusefi_config.txt +++ b/firmware/integration/rusefi_config.txt @@ -1200,7 +1200,11 @@ int16_t tps2Max;Full throttle#2. tpsMax value as 10 bit ADC value. Not Voltage!\ custom load_override_e 1 bits, U08, @OFFSET@, [0:2], @@load_override_e_enum@@ load_override_e afrOverrideMode;+Override the Y axis (load) value used for the AFR table.\nAdvanced users only: If you aren't sure you need this, you probably don't need this. - uint32_t unused1736;;"", 1, 0, 0, 536870911, 0 + uint8_t mc33_hpfp_i_peak;;"A", 0.1, 0, 0, 25, 1 + uint8_t mc33_hpfp_i_hold;;"A", 0.1, 0, 0, 25, 1 + uint8_t mc33_hpfp_i_hold_off;+How long to deactivate power when hold current is reached before applying power again;"us", 1, 0, 0, 255, 0 + uint8_t mc33_hpfp_max_hold;+Maximum amount of time the solenoid can be active before assuming a programming error;"ms", 1, 0, 0, 255, 0 + bit unused1740b0 bit unused1740b1 bit unused1740b2 diff --git a/firmware/tunerstudio/rusefi.input b/firmware/tunerstudio/rusefi.input index ae2c3f56b6..fb4583c80d 100644 --- a/firmware/tunerstudio/rusefi.input +++ b/firmware/tunerstudio/rusefi.input @@ -2199,7 +2199,7 @@ cmd_set_engine_type_default = "@@TS_IO_TEST_COMMAND_char@@\x00\x31\x00\x00" field = "Peak -> Hold Bypass Time", mc33_t_bypass field = "Hold current target", mc33_i_hold - field = "mc33_t_hold_off ?????", mc33_t_hold_off + field = "Hold off time", mc33_t_hold_off field = "Maximum injection duration", mc33_t_hold_tot @@ -3730,6 +3730,10 @@ cmd_set_engine_type_default = "@@TS_IO_TEST_COMMAND_char@@\x00\x31\x00\x00" dialog = hpfpPumpDialog, "HPFP Pump Configuration" field = "Valve Pin", hpfpValvePin, {hpfpCamLobes != 0} field = "Valve Pin Mode", hpfpValvePinMode, {hpfpCamLobes != 0} + field = "Valve peak current", mc33_hpfp_i_peak, {hpfpCamLobes != 0} + field = "Valve hold current", mc33_hpfp_i_hold, {hpfpCamLobes != 0} + field = "Valve hold off time", mc33_hpfp_i_hold_off, {hpfpCamLobes != 0} + field = "Valve maximum duration", mc33_hpfp_max_hold, {hpfpCamLobes != 0} field = "Pump volume", hpfpPumpVolume, {hpfpCamLobes != 0} field = "Minimum angle", hpfpMinAngle, {hpfpCamLobes != 0} field = "Activation angle", hpfpActivationAngle, {hpfpCamLobes != 0}