mirror of https://github.com/rusefi/rusefi-1.git
0R 0805 fab issue
This commit is contained in:
parent
904184c869
commit
f5b59187cb
|
@ -7,5 +7,7 @@
|
||||||
7) RESOLVED IN R0.2 set solder mask to 0.003 inches, per OSHPark suggestion.
|
7) RESOLVED IN R0.2 set solder mask to 0.003 inches, per OSHPark suggestion.
|
||||||
8) RESOLVED IN R0.3 Check if there is a chance to match discovery board reset button location
|
8) RESOLVED IN R0.3 Check if there is a chance to match discovery board reset button location
|
||||||
9) RESOLVED IN R0.3 Move push buttons to match the STM32F407 Discovery board's locations.
|
9) RESOLVED IN R0.3 Move push buttons to match the STM32F407 Discovery board's locations.
|
||||||
10) RESOLVED IN R0.3 Changed diodes to 0805 diodes.
|
10) RESOLVED IN R0.3 Changed diodes to 0805 diodes.
|
||||||
|
11) Some fab shops do not like soldering 0R 0805 on JUMPER footprint. Need to convert JP1, JP2, JP3 & JP4 to "SM0805_jumper"
|
||||||
|
|
||||||
|
|
||||||
|
|
|
@ -139,6 +139,7 @@
|
||||||
139) RESOLVED IN R0.5 Change D1004 from VS-50WQ04FNPBF to VS-50WQ04FN-M3
|
139) RESOLVED IN R0.5 Change D1004 from VS-50WQ04FNPBF to VS-50WQ04FN-M3
|
||||||
140) D1006 "alt diode for D1004" app note needs to get back to power supply page
|
140) D1006 "alt diode for D1004" app note needs to get back to power supply page
|
||||||
141) add an app note regarding not having separate injector/analog/else GND on Frankenso
|
141) add an app note regarding not having separate injector/analog/else GND on Frankenso
|
||||||
|
142) Some fab shops do not like soldering 0R 0805 on JUMPER footprint. Need to convert JPO1, JPO4 JPO5 "SM0805_jumper"
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|