rusefi-1/hardware/Breakout_72pin_1123038-2-Co.../1123038-2.net

479 lines
16 KiB
Plaintext

(export (version D)
(design
(source C:\Users\Vista_64_D630\Desktop\Jared\code\Hardware\trunk\rusefi.com\1123038-2-connector\1123038-2.sch)
(date "12/23/2016 5:35:19 PM")
(tool "Eeschema 4.0.1-stable")
(sheet (number 1) (name /) (tstamps /)
(title_block
(title "ECU adapter")
(company "DAECU for rusEFI")
(rev R0.3)
(date 2016-12-23)
(source 1123038-2.sch)
(comment (number 1) (value ""))
(comment (number 2) (value ""))
(comment (number 3) (value ""))
(comment (number 4) (value "")))))
(components
(comp (ref P1)
(value CONN_1)
(footprint 1pin)
(libsource (lib conn) (part CONN_01X01))
(sheetpath (names /) (tstamps /))
(tstamp 5374C241))
(comp (ref P2)
(value CONN_1)
(footprint 1pin)
(libsource (lib conn) (part CONN_01X01))
(sheetpath (names /) (tstamps /))
(tstamp 5374C093))
(comp (ref P10)
(value 1123038-2)
(footprint 1123038-2)
(datasheet DOCUMENTATION)
(libsource (lib 1123038-2) (part 1123038-2))
(sheetpath (names /) (tstamps /))
(tstamp 57F1B83D))
(comp (ref P5)
(value CONN_01X06)
(footprint Molex_NanoFit_1x06x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X06))
(sheetpath (names /) (tstamps /))
(tstamp 57F1BCB0))
(comp (ref P14)
(value CONN_01X06)
(footprint Molex_NanoFit_1x06x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X06))
(sheetpath (names /) (tstamps /))
(tstamp 57F1BF4F))
(comp (ref P6)
(value CONN_01X05)
(footprint Molex_NanoFit_1x05x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X05))
(sheetpath (names /) (tstamps /))
(tstamp 57F1C00C))
(comp (ref P9)
(value CONN_01X05)
(footprint Molex_NanoFit_1x05x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X05))
(sheetpath (names /) (tstamps /))
(tstamp 57F1C0D7))
(comp (ref P4)
(value CONN_01X06)
(footprint Molex_NanoFit_1x06x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X06))
(sheetpath (names /) (tstamps /))
(tstamp 57F1C476))
(comp (ref P8)
(value CONN_01X08)
(footprint Molex_NanoFit_1x08x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X08))
(sheetpath (names /) (tstamps /))
(tstamp 57F1C534))
(comp (ref P13)
(value CONN_01X08)
(footprint Molex_NanoFit_1x08x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X08))
(sheetpath (names /) (tstamps /))
(tstamp 57F1C6E2))
(comp (ref P11)
(value CONN_01X05)
(footprint Molex_NanoFit_1x05x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X05))
(sheetpath (names /) (tstamps /))
(tstamp 57F1C764))
(comp (ref P7)
(value CONN_01X08)
(footprint Molex_NanoFit_1x08x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X08))
(sheetpath (names /) (tstamps /))
(tstamp 57F1CB2B))
(comp (ref P12)
(value CONN_01X05)
(footprint Molex_NanoFit_1x05x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X05))
(sheetpath (names /) (tstamps /))
(tstamp 57F1CBAE))
(comp (ref P15)
(value CONN_01X05)
(footprint Molex_NanoFit_1x05x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X05))
(sheetpath (names /) (tstamps /))
(tstamp 57F1CE3C))
(comp (ref P3)
(value CONN_01X05)
(footprint Molex_NanoFit_1x05x2.50mm_Straight)
(libsource (lib conn) (part CONN_01X05))
(sheetpath (names /) (tstamps /))
(tstamp 57F1D074)))
(libparts
(libpart (lib 1123038-2) (part 1123038-2)
(footprints
(fp 1123038-2))
(fields
(field (name Reference) P)
(field (name Value) 1123038-2)
(field (name Footprint) MODULE)
(field (name Datasheet) DOCUMENTATION))
(pins
(pin (num 1) (name 2C) (type passive))
(pin (num 2) (name 2F) (type passive))
(pin (num 3) (name 2I) (type passive))
(pin (num 4) (name 2O) (type passive))
(pin (num 5) (name 2R) (type passive))
(pin (num 6) (name 3C) (type passive))
(pin (num 7) (name 3F) (type passive))
(pin (num 8) (name 3I) (type passive))
(pin (num 9) (name 3L) (type passive))
(pin (num 10) (name 3O) (type passive))
(pin (num 11) (name 3T) (type passive))
(pin (num 12) (name 3W) (type passive))
(pin (num 13) (name 3Z) (type passive))
(pin (num 14) (name 4C) (type passive))
(pin (num 15) (name 4F) (type passive))
(pin (num 16) (name 4I) (type passive))
(pin (num 17) (name 4K) (type passive))
(pin (num 18) (name 4N) (type passive))
(pin (num 19) (name 4T) (type passive))
(pin (num 20) (name 4W) (type passive))
(pin (num 21) (name 4AB) (type passive))
(pin (num 22) (name 4AE) (type passive))
(pin (num 23) (name 4AH) (type passive))
(pin (num 24) (name 2B) (type passive))
(pin (num 25) (name 2E) (type passive))
(pin (num 26) (name 2H) (type passive))
(pin (num 27) (name 2K) (type passive))
(pin (num 28) (name 2N) (type passive))
(pin (num 29) (name 2Q) (type passive))
(pin (num 30) (name 3B) (type passive))
(pin (num 31) (name 3E) (type passive))
(pin (num 32) (name 3H) (type passive))
(pin (num 33) (name 3K) (type passive))
(pin (num 34) (name 3N) (type passive))
(pin (num 35) (name 3Q) (type passive))
(pin (num 36) (name 3S) (type passive))
(pin (num 37) (name 3V) (type passive))
(pin (num 38) (name 3Y) (type passive))
(pin (num 39) (name 4B) (type passive))
(pin (num 40) (name 4E) (type passive))
(pin (num 41) (name 4H) (type passive))
(pin (num 42) (name 4J) (type passive))
(pin (num 43) (name 4M) (type passive))
(pin (num 44) (name 4P) (type passive))
(pin (num 45) (name 4S) (type passive))
(pin (num 46) (name 4V) (type passive))
(pin (num 47) (name 4X) (type passive))
(pin (num 48) (name 4AA) (type passive))
(pin (num 49) (name 4AD) (type passive))
(pin (num 50) (name 4AG) (type passive))
(pin (num 51) (name 2A) (type passive))
(pin (num 52) (name 2D) (type passive))
(pin (num 53) (name 2G) (type passive))
(pin (num 54) (name 2J) (type passive))
(pin (num 55) (name 2M) (type passive))
(pin (num 56) (name 2P) (type passive))
(pin (num 57) (name 3A) (type passive))
(pin (num 58) (name 3D) (type passive))
(pin (num 59) (name 3J) (type passive))
(pin (num 60) (name 3M) (type passive))
(pin (num 61) (name 3P) (type passive))
(pin (num 62) (name 3U) (type passive))
(pin (num 63) (name 3X) (type passive))
(pin (num 64) (name 4A) (type passive))
(pin (num 65) (name 4D) (type passive))
(pin (num 66) (name 4L) (type passive))
(pin (num 67) (name 4O) (type passive))
(pin (num 68) (name 4R) (type passive))
(pin (num 69) (name 4U) (type passive))
(pin (num 70) (name 4Z) (type passive))
(pin (num 71) (name 4AC) (type passive))
(pin (num 72) (name 4AF) (type passive))))
(libpart (lib conn) (part CONN_01X01)
(description "Connector 01x01")
(footprints
(fp Pin_Header_Straight_1X01)
(fp Pin_Header_Angled_1X01)
(fp Socket_Strip_Straight_1X01)
(fp Socket_Strip_Angled_1X01))
(fields
(field (name Reference) P)
(field (name Value) CONN_01X01))
(pins
(pin (num 1) (name P1) (type passive))))
(libpart (lib conn) (part CONN_01X05)
(description "Connector 01x05")
(footprints
(fp Pin_Header_Straight_1X05)
(fp Pin_Header_Angled_1X05)
(fp Socket_Strip_Straight_1X05)
(fp Socket_Strip_Angled_1X05))
(fields
(field (name Reference) P)
(field (name Value) CONN_01X05))
(pins
(pin (num 1) (name P1) (type passive))
(pin (num 2) (name P2) (type passive))
(pin (num 3) (name P3) (type passive))
(pin (num 4) (name P4) (type passive))
(pin (num 5) (name P5) (type passive))))
(libpart (lib conn) (part CONN_01X06)
(description "Connector 01x06")
(footprints
(fp Pin_Header_Straight_1X06)
(fp Pin_Header_Angled_1X06)
(fp Socket_Strip_Straight_1X06)
(fp Socket_Strip_Angled_1X06))
(fields
(field (name Reference) P)
(field (name Value) CONN_01X06))
(pins
(pin (num 1) (name P1) (type passive))
(pin (num 2) (name P2) (type passive))
(pin (num 3) (name P3) (type passive))
(pin (num 4) (name P4) (type passive))
(pin (num 5) (name P5) (type passive))
(pin (num 6) (name P6) (type passive))))
(libpart (lib conn) (part CONN_01X08)
(description "Connector 01x08")
(footprints
(fp Pin_Header_Straight_1X08)
(fp Pin_Header_Angled_1X08)
(fp Socket_Strip_Straight_1X08)
(fp Socket_Strip_Angled_1X08))
(fields
(field (name Reference) P)
(field (name Value) CONN_01X08))
(pins
(pin (num 1) (name P1) (type passive))
(pin (num 2) (name P2) (type passive))
(pin (num 3) (name P3) (type passive))
(pin (num 4) (name P4) (type passive))
(pin (num 5) (name P5) (type passive))
(pin (num 6) (name P6) (type passive))
(pin (num 7) (name P7) (type passive))
(pin (num 8) (name P8) (type passive)))))
(libraries
(library (logical conn)
(uri "C:\\Program Files\\KiCad\\share\\kicad\\library\\conn.lib"))
(library (logical 1123038-2)
(uri C:\Users\Vista_64_D630\Desktop\Jared\code\Hardware\trunk\rusefi.com\1123038-2-connector\..\rusefi_lib\1123038-2.lib)))
(nets
(net (code 1) (name /2R)
(node (ref P10) (pin 5))
(node (ref P3) (pin 5)))
(net (code 2) (name /20)
(node (ref P10) (pin 4))
(node (ref P3) (pin 4)))
(net (code 3) (name /2I)
(node (ref P3) (pin 3))
(node (ref P10) (pin 3)))
(net (code 4) (name /2F)
(node (ref P3) (pin 2))
(node (ref P10) (pin 2)))
(net (code 5) (name /2C)
(node (ref P3) (pin 1))
(node (ref P10) (pin 1)))
(net (code 6) (name /4N)
(node (ref P12) (pin 5))
(node (ref P10) (pin 18)))
(net (code 7) (name /4T)
(node (ref P10) (pin 19))
(node (ref P15) (pin 1)))
(net (code 8) (name /4W)
(node (ref P15) (pin 2))
(node (ref P10) (pin 20)))
(net (code 9) (name /3X)
(node (ref P10) (pin 63))
(node (ref P9) (pin 2)))
(net (code 10) (name /4AF)
(node (ref P10) (pin 72))
(node (ref P14) (pin 6)))
(net (code 11) (name /4L)
(node (ref P9) (pin 5))
(node (ref P10) (pin 66)))
(net (code 12) (name /4D)
(node (ref P10) (pin 65))
(node (ref P9) (pin 4)))
(net (code 13) (name /4A)
(node (ref P9) (pin 3))
(node (ref P10) (pin 64)))
(net (code 14) (name /3U)
(node (ref P9) (pin 1))
(node (ref P10) (pin 62)))
(net (code 15) (name /4C)
(node (ref P10) (pin 14))
(node (ref P12) (pin 1)))
(net (code 16) (name /4F)
(node (ref P12) (pin 2))
(node (ref P10) (pin 15)))
(net (code 17) (name /4I)
(node (ref P12) (pin 3))
(node (ref P10) (pin 16)))
(net (code 18) (name /4K)
(node (ref P10) (pin 17))
(node (ref P12) (pin 4)))
(net (code 19) (name /3I)
(node (ref P7) (pin 3))
(node (ref P10) (pin 8)))
(net (code 20) (name /3F)
(node (ref P7) (pin 2))
(node (ref P10) (pin 7)))
(net (code 21) (name /3C)
(node (ref P7) (pin 1))
(node (ref P10) (pin 6)))
(net (code 22) (name /3L)
(node (ref P7) (pin 4))
(node (ref P10) (pin 9)))
(net (code 23) (name /3O)
(node (ref P10) (pin 10))
(node (ref P7) (pin 5)))
(net (code 24) (name /3Y)
(node (ref P10) (pin 38))
(node (ref P11) (pin 1)))
(net (code 25) (name /3Z)
(node (ref P7) (pin 8))
(node (ref P10) (pin 13)))
(net (code 26) (name /4AB)
(node (ref P15) (pin 3))
(node (ref P10) (pin 21)))
(net (code 27) (name /4AE)
(node (ref P15) (pin 4))
(node (ref P10) (pin 22)))
(net (code 28) (name /4AH)
(node (ref P10) (pin 23))
(node (ref P15) (pin 5)))
(net (code 29) (name /3W)
(node (ref P7) (pin 7))
(node (ref P10) (pin 12)))
(net (code 30) (name /3T)
(node (ref P10) (pin 11))
(node (ref P7) (pin 6)))
(net (code 31) (name /4B)
(node (ref P11) (pin 2))
(node (ref P10) (pin 39)))
(net (code 32) (name /3D)
(node (ref P10) (pin 58))
(node (ref P6) (pin 2)))
(net (code 33) (name /3Q)
(node (ref P8) (pin 6))
(node (ref P10) (pin 35)))
(net (code 34) (name /2E)
(node (ref P10) (pin 25))
(node (ref P4) (pin 2)))
(net (code 35) (name /2J)
(node (ref P5) (pin 4))
(node (ref P10) (pin 54)))
(net (code 36) (name /4P)
(node (ref P13) (pin 2))
(node (ref P10) (pin 44)))
(net (code 37) (name /3N)
(node (ref P8) (pin 5))
(node (ref P10) (pin 34)))
(net (code 38) (name /2B)
(node (ref P4) (pin 1))
(node (ref P10) (pin 24)))
(net (code 39) (name /4S)
(node (ref P10) (pin 45))
(node (ref P13) (pin 3)))
(net (code 40) (name /2G)
(node (ref P5) (pin 3))
(node (ref P10) (pin 53)))
(net (code 41) (name /4M)
(node (ref P13) (pin 1))
(node (ref P10) (pin 43)))
(net (code 42) (name /3K)
(node (ref P10) (pin 33))
(node (ref P8) (pin 4)))
(net (code 43) (name /2N)
(node (ref P10) (pin 28))
(node (ref P4) (pin 5)))
(net (code 44) (name /4O)
(node (ref P14) (pin 1))
(node (ref P10) (pin 67)))
(net (code 45) (name /3A)
(node (ref P10) (pin 57))
(node (ref P6) (pin 1)))
(net (code 46) (name /4X)
(node (ref P13) (pin 5))
(node (ref P10) (pin 47)))
(net (code 47) (name /3V)
(node (ref P10) (pin 37))
(node (ref P8) (pin 8)))
(net (code 48) (name /2K)
(node (ref P10) (pin 27))
(node (ref P4) (pin 4)))
(net (code 49) (name /2D)
(node (ref P5) (pin 2))
(node (ref P10) (pin 52)))
(net (code 50) (name /2P)
(node (ref P10) (pin 56))
(node (ref P5) (pin 6)))
(net (code 51) (name /4V)
(node (ref P10) (pin 46))
(node (ref P13) (pin 4)))
(net (code 52) (name /3S)
(node (ref P8) (pin 7))
(node (ref P10) (pin 36)))
(net (code 53) (name /2H)
(node (ref P10) (pin 26))
(node (ref P4) (pin 3)))
(net (code 54) (name /2M)
(node (ref P5) (pin 5))
(node (ref P10) (pin 55)))
(net (code 55) (name GND)
(node (ref P1) (pin 1))
(node (ref P2) (pin 1)))
(net (code 56) (name /3E)
(node (ref P10) (pin 31))
(node (ref P8) (pin 2)))
(net (code 57) (name /4J)
(node (ref P10) (pin 42))
(node (ref P11) (pin 5)))
(net (code 58) (name /3H)
(node (ref P8) (pin 3))
(node (ref P10) (pin 32)))
(net (code 59) (name /4AC)
(node (ref P14) (pin 5))
(node (ref P10) (pin 71)))
(net (code 60) (name /3P)
(node (ref P6) (pin 5))
(node (ref P10) (pin 61)))
(net (code 61) (name /2A)
(node (ref P10) (pin 51))
(node (ref P5) (pin 1)))
(net (code 62) (name /4H)
(node (ref P11) (pin 4))
(node (ref P10) (pin 41)))
(net (code 63) (name /4AA)
(node (ref P13) (pin 6))
(node (ref P10) (pin 48)))
(net (code 64) (name /4Z)
(node (ref P10) (pin 70))
(node (ref P14) (pin 4)))
(net (code 65) (name /3M)
(node (ref P6) (pin 4))
(node (ref P10) (pin 60)))
(net (code 66) (name /4AG)
(node (ref P10) (pin 50))
(node (ref P13) (pin 8)))
(net (code 67) (name /4E)
(node (ref P11) (pin 3))
(node (ref P10) (pin 40)))
(net (code 68) (name /3B)
(node (ref P10) (pin 30))
(node (ref P8) (pin 1)))
(net (code 69) (name /2Q)
(node (ref P4) (pin 6))
(node (ref P10) (pin 29)))
(net (code 70) (name /4AD)
(node (ref P13) (pin 7))
(node (ref P10) (pin 49)))
(net (code 71) (name /4U)
(node (ref P14) (pin 3))
(node (ref P10) (pin 69)))
(net (code 72) (name /4R)
(node (ref P14) (pin 2))
(node (ref P10) (pin 68)))
(net (code 73) (name /3J)
(node (ref P6) (pin 3))
(node (ref P10) (pin 59)))))