rusefi-full/hardware/CJ125_board/known_issues.txt

7 lines
440 B
Plaintext
Raw Normal View History

2017-01-30 20:05:07 -08:00
1) RESOLVED IN R0.2 SOIC24 wrong size
2) RESOLVED IN R0.2 Q1 MOSFET is not connected properly.
3) RESOLVED IN R0.3 DIAHD silkscreen on pad #6 should be DIAHG
4) RESOLVED IN R0.3 add a note describing UR (R8) and UA (R15) low pass filter / slew rate limiter
5) RESOLVED IN R0.3 Correct C9 should match C2 for 1kHz low pass filter.
2017-02-03 20:04:50 -08:00
6) RESOLVED IN R0.3 R12 is not routed right
7) voltage divider on UR and UA channels