Auto-generated configs and docs
This commit is contained in:
parent
e01aa6139b
commit
391218b562
|
@ -1,4 +1,4 @@
|
|||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:42 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:41 UTC 2021
|
||||
// by class com.rusefi.output.CHeaderConsumer
|
||||
// begin
|
||||
#pragma once
|
||||
|
@ -3712,10 +3712,14 @@ struct engine_configuration_s {
|
|||
*/
|
||||
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3628
|
||||
*/
|
||||
uint8_t unused3328[236];
|
||||
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3756
|
||||
*/
|
||||
uint8_t unused3328[108];
|
||||
/**
|
||||
Min tCharge Coeff.
|
||||
* offset 3864
|
||||
|
@ -4541,4 +4545,4 @@ struct persistent_config_s {
|
|||
};
|
||||
|
||||
// end
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:42 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:41 UTC 2021
|
||||
|
|
|
@ -1773,6 +1773,14 @@
|
|||
#define scriptSetting6_offset 884
|
||||
#define scriptSetting7_offset 888
|
||||
#define scriptSetting8_offset 892
|
||||
#define scriptSettingName1_offset 3628
|
||||
#define scriptSettingName2_offset 3644
|
||||
#define scriptSettingName3_offset 3660
|
||||
#define scriptSettingName4_offset 3676
|
||||
#define scriptSettingName5_offset 3692
|
||||
#define scriptSettingName6_offset 3708
|
||||
#define scriptSettingName7_offset 3724
|
||||
#define scriptSettingName8_offset 3740
|
||||
#define scriptTable1_offset 19296
|
||||
#define scriptTable1LoadBins_offset 19552
|
||||
#define scriptTable1RpmBins_offset 19584
|
||||
|
@ -1818,7 +1826,7 @@
|
|||
#define show_test_presets true
|
||||
#define showHumanReadableWarning_offset 976
|
||||
#define showSdCardWarning_offset 76
|
||||
#define SIGNATURE_HASH 2319440833
|
||||
#define SIGNATURE_HASH 1575955825
|
||||
#define silentTriggerError_offset 1464
|
||||
#define slowAdcAlpha_offset 2088
|
||||
#define sparkDwellRpmBins_offset 332
|
||||
|
@ -2337,7 +2345,7 @@
|
|||
#define ts_show_spi true
|
||||
#define ts_show_trigger_comparator false
|
||||
#define ts_show_tunerstudio_port true
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.2319440833"
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.1575955825"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
|
@ -2376,7 +2384,7 @@
|
|||
#define unused2508_offset 2511
|
||||
#define unused2536_offset 2539
|
||||
#define unused3103_offset 3103
|
||||
#define unused3328_offset 3628
|
||||
#define unused3328_offset 3756
|
||||
#define unused3942_offset 3992
|
||||
#define unused3988_offset 3988
|
||||
#define unused4028_offset 4028
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:40 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:38 UTC 2021
|
||||
// by class com.rusefi.output.CHeaderConsumer
|
||||
// begin
|
||||
#pragma once
|
||||
|
@ -3706,10 +3706,14 @@ struct engine_configuration_s {
|
|||
*/
|
||||
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3600
|
||||
*/
|
||||
uint8_t unused3328[236];
|
||||
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3728
|
||||
*/
|
||||
uint8_t unused3328[108];
|
||||
/**
|
||||
Min tCharge Coeff.
|
||||
* offset 3836
|
||||
|
@ -4535,4 +4539,4 @@ struct persistent_config_s {
|
|||
};
|
||||
|
||||
// end
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:40 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:38 UTC 2021
|
||||
|
|
|
@ -1758,6 +1758,14 @@
|
|||
#define scriptSetting6_offset 884
|
||||
#define scriptSetting7_offset 888
|
||||
#define scriptSetting8_offset 892
|
||||
#define scriptSettingName1_offset 3600
|
||||
#define scriptSettingName2_offset 3616
|
||||
#define scriptSettingName3_offset 3632
|
||||
#define scriptSettingName4_offset 3648
|
||||
#define scriptSettingName5_offset 3664
|
||||
#define scriptSettingName6_offset 3680
|
||||
#define scriptSettingName7_offset 3696
|
||||
#define scriptSettingName8_offset 3712
|
||||
#define scriptTable1_offset 19268
|
||||
#define scriptTable1LoadBins_offset 19524
|
||||
#define scriptTable1RpmBins_offset 19556
|
||||
|
@ -1803,7 +1811,7 @@
|
|||
#define show_test_presets true
|
||||
#define showHumanReadableWarning_offset 976
|
||||
#define showSdCardWarning_offset 76
|
||||
#define SIGNATURE_HASH 1973032765
|
||||
#define SIGNATURE_HASH 2722816397
|
||||
#define silentTriggerError_offset 1464
|
||||
#define slowAdcAlpha_offset 2088
|
||||
#define sparkDwellRpmBins_offset 332
|
||||
|
@ -2322,7 +2330,7 @@
|
|||
#define ts_show_spi true
|
||||
#define ts_show_trigger_comparator true
|
||||
#define ts_show_tunerstudio_port true
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.1973032765"
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.2722816397"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
|
@ -2361,7 +2369,7 @@
|
|||
#define unused2508_offset 2503
|
||||
#define unused2536_offset 2531
|
||||
#define unused3103_offset 3075
|
||||
#define unused3328_offset 3600
|
||||
#define unused3328_offset 3728
|
||||
#define unused3942_offset 3964
|
||||
#define unused3988_offset 3960
|
||||
#define unused4028_offset 4000
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:45 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:44 UTC 2021
|
||||
// by class com.rusefi.output.CHeaderConsumer
|
||||
// begin
|
||||
#pragma once
|
||||
|
@ -3712,10 +3712,14 @@ struct engine_configuration_s {
|
|||
*/
|
||||
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3628
|
||||
*/
|
||||
uint8_t unused3328[236];
|
||||
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3756
|
||||
*/
|
||||
uint8_t unused3328[108];
|
||||
/**
|
||||
Min tCharge Coeff.
|
||||
* offset 3864
|
||||
|
@ -4541,4 +4545,4 @@ struct persistent_config_s {
|
|||
};
|
||||
|
||||
// end
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:45 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:44 UTC 2021
|
||||
|
|
|
@ -1785,6 +1785,14 @@
|
|||
#define scriptSetting6_offset 884
|
||||
#define scriptSetting7_offset 888
|
||||
#define scriptSetting8_offset 892
|
||||
#define scriptSettingName1_offset 3628
|
||||
#define scriptSettingName2_offset 3644
|
||||
#define scriptSettingName3_offset 3660
|
||||
#define scriptSettingName4_offset 3676
|
||||
#define scriptSettingName5_offset 3692
|
||||
#define scriptSettingName6_offset 3708
|
||||
#define scriptSettingName7_offset 3724
|
||||
#define scriptSettingName8_offset 3740
|
||||
#define scriptTable1_offset 19296
|
||||
#define scriptTable1LoadBins_offset 19552
|
||||
#define scriptTable1RpmBins_offset 19584
|
||||
|
@ -1831,7 +1839,7 @@
|
|||
#define show_test_presets false
|
||||
#define showHumanReadableWarning_offset 976
|
||||
#define showSdCardWarning_offset 76
|
||||
#define SIGNATURE_HASH 1936730669
|
||||
#define SIGNATURE_HASH 2762005661
|
||||
#define silentTriggerError_offset 1464
|
||||
#define slowAdcAlpha_offset 2088
|
||||
#define sparkDwellRpmBins_offset 332
|
||||
|
@ -2350,7 +2358,7 @@
|
|||
#define ts_show_spi true
|
||||
#define ts_show_trigger_comparator false
|
||||
#define ts_show_tunerstudio_port false
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.1936730669"
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.2762005661"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
|
@ -2389,7 +2397,7 @@
|
|||
#define unused2508_offset 2511
|
||||
#define unused2536_offset 2539
|
||||
#define unused3103_offset 3103
|
||||
#define unused3328_offset 3628
|
||||
#define unused3328_offset 3756
|
||||
#define unused3942_offset 3992
|
||||
#define unused3988_offset 3988
|
||||
#define unused4028_offset 4028
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
// by class com.rusefi.output.CHeaderConsumer
|
||||
// begin
|
||||
#pragma once
|
||||
|
@ -3712,10 +3712,14 @@ struct engine_configuration_s {
|
|||
*/
|
||||
gppwm_note_t scriptTableName[SCRIPT_TABLE_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3628
|
||||
*/
|
||||
uint8_t unused3328[236];
|
||||
gppwm_note_t scriptSettingName[SCRIPT_SETTING_COUNT];
|
||||
/**
|
||||
units
|
||||
* offset 3756
|
||||
*/
|
||||
uint8_t unused3328[108];
|
||||
/**
|
||||
Min tCharge Coeff.
|
||||
* offset 3864
|
||||
|
@ -4541,4 +4545,4 @@ struct persistent_config_s {
|
|||
};
|
||||
|
||||
// end
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
// this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
|
|
|
@ -1,3 +1,3 @@
|
|||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
|
||||
// by class com.rusefi.output.FileFsioSettingsConsumer
|
||||
|
|
|
@ -1,3 +1,3 @@
|
|||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
|
||||
// by class com.rusefi.output.FileFsioSettingsConsumer
|
||||
|
|
|
@ -1,3 +1,3 @@
|
|||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
|
||||
// by class com.rusefi.output.FileFsioSettingsConsumer
|
||||
|
|
|
@ -1,3 +1,3 @@
|
|||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
|
||||
// by class com.rusefi.output.FileFsioSettingsConsumer
|
||||
|
|
|
@ -1773,6 +1773,14 @@
|
|||
#define scriptSetting6_offset 884
|
||||
#define scriptSetting7_offset 888
|
||||
#define scriptSetting8_offset 892
|
||||
#define scriptSettingName1_offset 3628
|
||||
#define scriptSettingName2_offset 3644
|
||||
#define scriptSettingName3_offset 3660
|
||||
#define scriptSettingName4_offset 3676
|
||||
#define scriptSettingName5_offset 3692
|
||||
#define scriptSettingName6_offset 3708
|
||||
#define scriptSettingName7_offset 3724
|
||||
#define scriptSettingName8_offset 3740
|
||||
#define scriptTable1_offset 19296
|
||||
#define scriptTable1LoadBins_offset 19552
|
||||
#define scriptTable1RpmBins_offset 19584
|
||||
|
@ -1818,7 +1826,7 @@
|
|||
#define show_test_presets true
|
||||
#define showHumanReadableWarning_offset 976
|
||||
#define showSdCardWarning_offset 76
|
||||
#define SIGNATURE_HASH 2966043773
|
||||
#define SIGNATURE_HASH 1729809101
|
||||
#define silentTriggerError_offset 1464
|
||||
#define slowAdcAlpha_offset 2088
|
||||
#define sparkDwellRpmBins_offset 332
|
||||
|
@ -2337,7 +2345,7 @@
|
|||
#define ts_show_spi true
|
||||
#define ts_show_trigger_comparator false
|
||||
#define ts_show_tunerstudio_port true
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.all.2966043773"
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.all.1729809101"
|
||||
#define TS_SINGLE_WRITE_COMMAND 'W'
|
||||
#define TS_SINGLE_WRITE_COMMAND_char W
|
||||
#define TS_TEST_COMMAND 't'
|
||||
|
@ -2376,7 +2384,7 @@
|
|||
#define unused2508_offset 2511
|
||||
#define unused2536_offset 2539
|
||||
#define unused3103_offset 3103
|
||||
#define unused3328_offset 3628
|
||||
#define unused3328_offset 3756
|
||||
#define unused3942_offset 3992
|
||||
#define unused3988_offset 3988
|
||||
#define unused4028_offset 4028
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 2966043773
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.all.2966043773"
|
||||
#define SIGNATURE_HASH 1729809101
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.all.1729809101"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 2885732698
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.atlas.2885732698"
|
||||
#define SIGNATURE_HASH 2077245418
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.atlas.2077245418"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 2966043773
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.f429-discovery.2966043773"
|
||||
#define SIGNATURE_HASH 1729809101
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.f429-discovery.1729809101"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 3405277588
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.frankenso_na6.3405277588"
|
||||
#define SIGNATURE_HASH 489201444
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.frankenso_na6.489201444"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 353897716
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen-nb1.353897716"
|
||||
#define SIGNATURE_HASH 3267951172
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen-nb1.3267951172"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 189685468
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121nissan.189685468"
|
||||
#define SIGNATURE_HASH 3701385324
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121nissan.3701385324"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 4016642167
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121vag.4016642167"
|
||||
#define SIGNATURE_HASH 951709383
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen121vag.951709383"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 705451994
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen128.705451994"
|
||||
#define SIGNATURE_HASH 4259094890
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen128.4259094890"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 2451455707
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen154hyundai.2451455707"
|
||||
#define SIGNATURE_HASH 1171179627
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen154hyundai.1171179627"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 1148697549
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen72.1148697549"
|
||||
#define SIGNATURE_HASH 2477215101
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen72.2477215101"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 285912354
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen88bmw.285912354"
|
||||
#define SIGNATURE_HASH 3336199058
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen88bmw.3336199058"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 3338107605
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellenNA6.3338107605"
|
||||
#define SIGNATURE_HASH 287804517
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellenNA6.287804517"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 2319440833
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.2319440833"
|
||||
#define SIGNATURE_HASH 1575955825
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.hellen_cypress.1575955825"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 1973032765
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.1973032765"
|
||||
#define SIGNATURE_HASH 2722816397
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.kin.2722816397"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 999380956
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f4.999380956"
|
||||
#define SIGNATURE_HASH 3963724140
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f4.3963724140"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 999380956
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f7.999380956"
|
||||
#define SIGNATURE_HASH 3963724140
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.mre_f7.3963724140"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 3760252315
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_405.3760252315"
|
||||
#define SIGNATURE_HASH 938480427
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_405.938480427"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 3760252315
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_469.3760252315"
|
||||
#define SIGNATURE_HASH 938480427
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.prometheus_469.938480427"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 464869372
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f4.464869372"
|
||||
#define SIGNATURE_HASH 3429212492
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f4.3429212492"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 464869372
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f7.464869372"
|
||||
#define SIGNATURE_HASH 3429212492
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.proteus_f7.3429212492"
|
||||
|
|
|
@ -2,5 +2,5 @@
|
|||
// was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt
|
||||
//
|
||||
|
||||
#define SIGNATURE_HASH 1936730669
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.1936730669"
|
||||
#define SIGNATURE_HASH 2762005661
|
||||
#define TS_SIGNATURE "rusEFI 2021.11.14.subaru_eg33_f7.2762005661"
|
||||
|
|
Binary file not shown.
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.all.2966043773"
|
||||
signature = "rusEFI 2021.11.14.all.1729809101"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.all.2966043773" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.all.1729809101" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.atlas.2885732698"
|
||||
signature = "rusEFI 2021.11.14.atlas.2077245418"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.atlas.2885732698" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.atlas.2077245418" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:34 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:32 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5150,12 +5158,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.f429-discovery.2966043773"
|
||||
signature = "rusEFI 2021.11.14.f429-discovery.1729809101"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.f429-discovery.2966043773" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.f429-discovery.1729809101" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:46 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:39 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.frankenso_na6.3405277588"
|
||||
signature = "rusEFI 2021.11.14.frankenso_na6.489201444"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.frankenso_na6.3405277588" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.frankenso_na6.489201444" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:20 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:15 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen-nb1.353897716"
|
||||
signature = "rusEFI 2021.11.14.hellen-nb1.3267951172"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen-nb1.353897716" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen-nb1.3267951172" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:08 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:03 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5135,12 +5143,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen121nissan.189685468"
|
||||
signature = "rusEFI 2021.11.14.hellen121nissan.3701385324"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen121nissan.189685468" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen121nissan.3701385324" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:56 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:49 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen121vag.4016642167"
|
||||
signature = "rusEFI 2021.11.14.hellen121vag.951709383"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen121vag.4016642167" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen121vag.951709383" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:52 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:46 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen128.705451994"
|
||||
signature = "rusEFI 2021.11.14.hellen128.4259094890"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen128.705451994" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen128.4259094890" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:49 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:43 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen154hyundai.2451455707"
|
||||
signature = "rusEFI 2021.11.14.hellen154hyundai.1171179627"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen154hyundai.2451455707" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen154hyundai.1171179627" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:50:59 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:53 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen72.1148697549"
|
||||
signature = "rusEFI 2021.11.14.hellen72.2477215101"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen72.1148697549" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen72.2477215101" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:04 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:59 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5135,12 +5143,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen88bmw.285912354"
|
||||
signature = "rusEFI 2021.11.14.hellen88bmw.3336199058"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen88bmw.285912354" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen88bmw.3336199058" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:01 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:48:56 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5134,12 +5142,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellenNA6.3338107605"
|
||||
signature = "rusEFI 2021.11.14.hellenNA6.287804517"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellenNA6.3338107605" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellenNA6.287804517" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:11 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:06 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5135,12 +5143,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.hellen_cypress.2319440833"
|
||||
signature = "rusEFI 2021.11.14.hellen_cypress.1575955825"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.hellen_cypress.2319440833" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.hellen_cypress.1575955825" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:42 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on hellen_cypress_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:41 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5158,12 +5166,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.kin.1973032765"
|
||||
signature = "rusEFI 2021.11.14.kin.2722816397"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.kin.1973032765" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.kin.2722816397" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 15:51:40 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on kinetis_gen_config.bat integration/rusefi_config.txt Sun Nov 14 16:49:38 UTC 2021
|
||||
|
||||
pageSize = 19972
|
||||
page = 1
|
||||
|
@ -1050,7 +1050,15 @@ scriptTableName1 = string, ASCII, 3536, 16
|
|||
scriptTableName2 = string, ASCII, 3552, 16
|
||||
scriptTableName3 = string, ASCII, 3568, 16
|
||||
scriptTableName4 = string, ASCII, 3584, 16
|
||||
unused3328 = array, U08, 3600, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3600, 16
|
||||
scriptSettingName2 = string, ASCII, 3616, 16
|
||||
scriptSettingName3 = string, ASCII, 3632, 16
|
||||
scriptSettingName4 = string, ASCII, 3648, 16
|
||||
scriptSettingName5 = string, ASCII, 3664, 16
|
||||
scriptSettingName6 = string, ASCII, 3680, 16
|
||||
scriptSettingName7 = string, ASCII, 3696, 16
|
||||
scriptSettingName8 = string, ASCII, 3712, 16
|
||||
unused3328 = array, U08, 3728, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3836, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3840, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3844, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5125,12 +5133,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.mre_f4.999380956"
|
||||
signature = "rusEFI 2021.11.14.mre_f4.3963724140"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.mre_f4.999380956" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.mre_f4.3963724140" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:17 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:12 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5133,12 +5141,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.mre_f7.999380956"
|
||||
signature = "rusEFI 2021.11.14.mre_f7.3963724140"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.mre_f7.999380956" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.mre_f7.3963724140" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:14 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:09 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5133,12 +5141,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.prometheus_405.3760252315"
|
||||
signature = "rusEFI 2021.11.14.prometheus_405.938480427"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.prometheus_405.3760252315" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.prometheus_405.938480427" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:26 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:22 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5153,12 +5161,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.prometheus_469.3760252315"
|
||||
signature = "rusEFI 2021.11.14.prometheus_469.938480427"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.prometheus_469.3760252315" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.prometheus_469.938480427" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:23 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:19 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5153,12 +5161,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.proteus_f4.464869372"
|
||||
signature = "rusEFI 2021.11.14.proteus_f4.3429212492"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.proteus_f4.464869372" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.proteus_f4.3429212492" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:31 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:28 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5126,12 +5134,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.proteus_f7.464869372"
|
||||
signature = "rusEFI 2021.11.14.proteus_f7.3429212492"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.proteus_f7.464869372" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.proteus_f7.3429212492" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:29 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:25 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5126,12 +5134,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -32,12 +32,12 @@ enable2ndByteCanID = false
|
|||
|
||||
[MegaTune]
|
||||
; https://rusefi.com/forum/viewtopic.php?p=36201#p36201
|
||||
signature = "rusEFI 2021.11.14.subaru_eg33_f7.1936730669"
|
||||
signature = "rusEFI 2021.11.14.subaru_eg33_f7.2762005661"
|
||||
|
||||
[TunerStudio]
|
||||
queryCommand = "S"
|
||||
versionInfo = "V" ; firmwave version for title bar.
|
||||
signature = "rusEFI 2021.11.14.subaru_eg33_f7.1936730669" ; signature is expected to be 7 or more characters.
|
||||
signature = "rusEFI 2021.11.14.subaru_eg33_f7.2762005661" ; signature is expected to be 7 or more characters.
|
||||
|
||||
; TS will try to use legacy temp units in some cases, showing "deg F" on a CLT gauge that's actually deg C
|
||||
useLegacyFTempUnits = false
|
||||
|
@ -85,7 +85,7 @@ enable2ndByteCanID = false
|
|||
|
||||
; see PAGE_0_SIZE in C source code
|
||||
; CONFIG_DEFINITION_START
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:45 UTC 2021
|
||||
; this section was generated automatically by rusEFI tool ConfigDefinition.jar based on config/boards/subaru_eg33/config/gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:44 UTC 2021
|
||||
|
||||
pageSize = 20000
|
||||
page = 1
|
||||
|
@ -1072,7 +1072,15 @@ scriptTableName1 = string, ASCII, 3564, 16
|
|||
scriptTableName2 = string, ASCII, 3580, 16
|
||||
scriptTableName3 = string, ASCII, 3596, 16
|
||||
scriptTableName4 = string, ASCII, 3612, 16
|
||||
unused3328 = array, U08, 3628, [236], "units", 1, 0, -20, 100, 0
|
||||
scriptSettingName1 = string, ASCII, 3628, 16
|
||||
scriptSettingName2 = string, ASCII, 3644, 16
|
||||
scriptSettingName3 = string, ASCII, 3660, 16
|
||||
scriptSettingName4 = string, ASCII, 3676, 16
|
||||
scriptSettingName5 = string, ASCII, 3692, 16
|
||||
scriptSettingName6 = string, ASCII, 3708, 16
|
||||
scriptSettingName7 = string, ASCII, 3724, 16
|
||||
scriptSettingName8 = string, ASCII, 3740, 16
|
||||
unused3328 = array, U08, 3756, [108], "units", 1, 0, -20, 100, 0
|
||||
tChargeAirCoefMin = scalar, F32, 3864, "Min tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirCoefMax = scalar, F32, 3868, "Max tCharge Coeff.", 1, 0, 0, 1, 4
|
||||
tChargeAirFlowMax = scalar, F32, 3872, "Max Air Flow (kg/h)", 1, 0, 0, 1000, 1
|
||||
|
@ -5149,12 +5157,18 @@ cmd_set_engine_type_default = "Z\x00\x31\x00\x00"
|
|||
field = "!Use rusEFI console for Lua script editing"
|
||||
field = "Set number is not associated with the output number."
|
||||
field = "Set number, only the cell number with some numbers."
|
||||
field = "set #1", scriptSetting1
|
||||
field = "set #2", scriptSetting2
|
||||
field = "set #3", scriptSetting3
|
||||
field = "set #4", scriptSetting4
|
||||
field = "set #5", scriptSetting5
|
||||
field = "set #6", scriptSetting6
|
||||
field = "Name #1", scriptSettingName1
|
||||
field = "Setting #1", scriptSetting1
|
||||
field = "Name #2", scriptSettingName2
|
||||
field = "Setting #2", scriptSetting2
|
||||
field = "Name #3", scriptSettingName3
|
||||
field = "Setting #3", scriptSetting3
|
||||
field = "Name #4", scriptSettingName4
|
||||
field = "Setting #4", scriptSetting4
|
||||
field = "Name #5", scriptSettingName5
|
||||
field = "Setting #5", scriptSetting5
|
||||
field = "Name #6", scriptSettingName6
|
||||
field = "Setting #6", scriptSetting6
|
||||
|
||||
dialog = scriptSettingDialog, "Script Settings", border
|
||||
panel = scriptSetting, East
|
||||
|
|
|
@ -1,6 +1,6 @@
|
|||
package com.rusefi.config.generated;
|
||||
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 15:51:37 UTC 2021
|
||||
// this file was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh integration/rusefi_config.txt Sun Nov 14 16:49:35 UTC 2021
|
||||
|
||||
// by class com.rusefi.output.FileJavaFieldsConsumer
|
||||
import com.rusefi.config.*;
|
||||
|
@ -1705,6 +1705,14 @@ public class Fields {
|
|||
public static final int scriptSetting6_offset = 884;
|
||||
public static final int scriptSetting7_offset = 888;
|
||||
public static final int scriptSetting8_offset = 892;
|
||||
public static final int scriptSettingName1_offset = 3628;
|
||||
public static final int scriptSettingName2_offset = 3644;
|
||||
public static final int scriptSettingName3_offset = 3660;
|
||||
public static final int scriptSettingName4_offset = 3676;
|
||||
public static final int scriptSettingName5_offset = 3692;
|
||||
public static final int scriptSettingName6_offset = 3708;
|
||||
public static final int scriptSettingName7_offset = 3724;
|
||||
public static final int scriptSettingName8_offset = 3740;
|
||||
public static final int scriptTable1_offset = 19296;
|
||||
public static final int scriptTable1LoadBins_offset = 19552;
|
||||
public static final int scriptTable1RpmBins_offset = 19584;
|
||||
|
@ -1745,6 +1753,7 @@ public class Fields {
|
|||
public static final int servoOutputPins8_offset = 3147;
|
||||
public static final int showHumanReadableWarning_offset = 976;
|
||||
public static final int showSdCardWarning_offset = 76;
|
||||
public static final int SIGNATURE_HASH = 1729809101;
|
||||
public static final int silentTriggerError_offset = 1464;
|
||||
public static final int slowAdcAlpha_offset = 2088;
|
||||
public static final int sparkDwellRpmBins_offset = 332;
|
||||
|
@ -2208,7 +2217,7 @@ public class Fields {
|
|||
public static final int TS_RESPONSE_UNDERRUN = 0x80;
|
||||
public static final int TS_RESPONSE_UNRECOGNIZED_COMMAND = 0x83;
|
||||
public static final char TS_SET_LOGGER_SWITCH = 'l';
|
||||
public static final String TS_SIGNATURE = "rusEFI 2021.11.14.all.2966043773";
|
||||
public static final String TS_SIGNATURE = "rusEFI 2021.11.14.all.1729809101";
|
||||
public static final char TS_SINGLE_WRITE_COMMAND = 'W';
|
||||
public static final char TS_TEST_COMMAND = 't';
|
||||
public static final int tunerStudioSerialSpeed_offset = 728;
|
||||
|
@ -2244,7 +2253,7 @@ public class Fields {
|
|||
public static final int unused2508_offset = 2511;
|
||||
public static final int unused2536_offset = 2539;
|
||||
public static final int unused3103_offset = 3103;
|
||||
public static final int unused3328_offset = 3628;
|
||||
public static final int unused3328_offset = 3756;
|
||||
public static final int unused3942_offset = 3992;
|
||||
public static final int unused3988_offset = 3988;
|
||||
public static final int unused4028_offset = 4028;
|
||||
|
@ -3429,7 +3438,15 @@ public class Fields {
|
|||
public static final Field SCRIPTTABLENAME2 = Field.create("SCRIPTTABLENAME2", 3580, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTTABLENAME3 = Field.create("SCRIPTTABLENAME3", 3596, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTTABLENAME4 = Field.create("SCRIPTTABLENAME4", 3612, 16, FieldType.STRING);
|
||||
public static final Field UNUSED3328 = Field.create("UNUSED3328", 3628, FieldType.INT8);
|
||||
public static final Field SCRIPTSETTINGNAME1 = Field.create("SCRIPTSETTINGNAME1", 3628, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTSETTINGNAME2 = Field.create("SCRIPTSETTINGNAME2", 3644, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTSETTINGNAME3 = Field.create("SCRIPTSETTINGNAME3", 3660, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTSETTINGNAME4 = Field.create("SCRIPTSETTINGNAME4", 3676, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTSETTINGNAME5 = Field.create("SCRIPTSETTINGNAME5", 3692, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTSETTINGNAME6 = Field.create("SCRIPTSETTINGNAME6", 3708, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTSETTINGNAME7 = Field.create("SCRIPTSETTINGNAME7", 3724, 16, FieldType.STRING);
|
||||
public static final Field SCRIPTSETTINGNAME8 = Field.create("SCRIPTSETTINGNAME8", 3740, 16, FieldType.STRING);
|
||||
public static final Field UNUSED3328 = Field.create("UNUSED3328", 3756, FieldType.INT8);
|
||||
public static final Field TCHARGEAIRCOEFMIN = Field.create("TCHARGEAIRCOEFMIN", 3864, FieldType.FLOAT);
|
||||
public static final Field TCHARGEAIRCOEFMAX = Field.create("TCHARGEAIRCOEFMAX", 3868, FieldType.FLOAT);
|
||||
public static final Field TCHARGEAIRFLOWMAX = Field.create("TCHARGEAIRFLOWMAX", 3872, FieldType.FLOAT);
|
||||
|
@ -4692,6 +4709,14 @@ public class Fields {
|
|||
SCRIPTTABLENAME2,
|
||||
SCRIPTTABLENAME3,
|
||||
SCRIPTTABLENAME4,
|
||||
SCRIPTSETTINGNAME1,
|
||||
SCRIPTSETTINGNAME2,
|
||||
SCRIPTSETTINGNAME3,
|
||||
SCRIPTSETTINGNAME4,
|
||||
SCRIPTSETTINGNAME5,
|
||||
SCRIPTSETTINGNAME6,
|
||||
SCRIPTSETTINGNAME7,
|
||||
SCRIPTSETTINGNAME8,
|
||||
UNUSED3328,
|
||||
TCHARGEAIRCOEFMIN,
|
||||
TCHARGEAIRCOEFMAX,
|
||||
|
|
|
@ -1,6 +1,6 @@
|
|||
<roms>
|
||||
|
||||
<!-- was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh Sun Nov 14 15:51:39 UTC 2021 -->
|
||||
<!-- was generated automatically by rusEFI tool ConfigDefinition.jar based on gen_config.sh Sun Nov 14 16:49:37 UTC 2021 -->
|
||||
|
||||
<rom>
|
||||
<romid>
|
||||
|
|
Loading…
Reference in New Issue