TLE8888: disable diagnostic for OUTPUT8..13 (#1956)
Enabled pull-down affects analog inputs that shares same pins. Disable it. DOTO: enable diagnostic if ouput requested through tle8888_setPadMode
This commit is contained in:
parent
774de10f40
commit
f48621e4c2
|
@ -643,9 +643,18 @@ static int tle8888_chip_init(struct tle8888_priv *chip)
|
|||
/* Enable open load detection and disable switch off
|
||||
* in case of overcurrent for OUTPUT5..7 */
|
||||
CMD_OUTCONFIG(1, BIT(5) | BIT(3) | BIT(1)),
|
||||
#if 1
|
||||
/* MRE 0.5.? share same outputs between OUTPUT8..13
|
||||
* and analog inputs. Disable diagnostic pull-down
|
||||
* not to affect analog inputs.
|
||||
* Disable open load detection and set short to bat
|
||||
* thresholt to 125 mV (default) for OUTPUT8..13 */
|
||||
CMD_OUTCONFIG(2, (0x0 << 6) | 0x00),
|
||||
#else
|
||||
/* Enable open load detection and set short to bat
|
||||
* thresholt to 125 mV (default) for OUTPUT8..13 */
|
||||
CMD_OUTCONFIG(2, (0x0 << 6) | BIT(5) | BIT(4) | BIT(3) | BIT(2) | BIT(1) | BIT(0)),
|
||||
#endif
|
||||
/* Enable open load detection and disable switch off
|
||||
* in case of overcurrent for OUTPUT14
|
||||
* Set short to bat threshold to 125mV (default) for
|
||||
|
|
Loading…