2020-12-12 15:48:18 -08:00
|
|
|
# NOTE: This is currently under development. This page might be wrong or change quickly.
|
|
|
|
|
2021-01-02 20:16:41 -08:00
|
|
|
## Pinout
|
|
|
|
|
|
|
|
![connector pinout image](https://imgur.com/LvCaQ1o.jpg)
|
|
|
|
|
|
|
|
| Pin Number | Function | Notes |
|
|
|
|
|:---:|:---:| ---|
|
|
|
|
| 1 | Ground | Connect to chassis ground |
|
2021-01-02 20:24:28 -08:00
|
|
|
| 2 | LSU Ip | Connect to sensor pin 1 |
|
|
|
|
| 3 | LSU Heater - | Connect to sensor pin 3 |
|
|
|
|
| 4 | LSU Heater + | Connect to sensor pin 4 |
|
2021-01-02 20:16:41 -08:00
|
|
|
| 5 | No connection | |
|
|
|
|
| 6 | 12v Supply | Connect to fuel pump supply or independent relay controlled by ECU |
|
|
|
|
| 7 | No connection | |
|
2021-01-02 20:24:28 -08:00
|
|
|
| 8 | LSU Vm | Connect to sensor pin 2 |
|
|
|
|
| 9 | LSU Rtrim | Connect to sensor pin 5 |
|
|
|
|
| 10 | LSU Un | Connect to sensor pin 6 |
|
2021-01-02 20:16:41 -08:00
|
|
|
| 11 | CAN H | CAN bus high |
|
|
|
|
| 12 | CAN L | CAN bus low |
|
2020-12-10 17:31:33 -08:00
|
|
|
|
|
|
|
## LED decoding
|
|
|
|
| Blue LED | Green LED | Meaning |
|
2020-12-10 18:26:36 -08:00
|
|
|
|:--------:|:---------:| -----|
|
2021-01-02 19:53:44 -08:00
|
|
|
| off | fast flash | sensor warming up |
|
|
|
|
| off | slow flash | Sensor hot, operating normally |
|
2020-12-10 21:56:17 -08:00
|
|
|
| flashing | off | See error code table below |
|
2021-03-13 15:48:25 -08:00
|
|
|
| alternating | alternating | Bootloader, see below |
|
2020-12-10 21:56:17 -08:00
|
|
|
|
2021-01-02 22:03:53 -08:00
|
|
|
## Firmware Update
|
|
|
|
|
|
|
|
coming soon...
|
2020-12-10 21:56:17 -08:00
|
|
|
|
|
|
|
## Error Codes
|
|
|
|
|
|
|
|
Green LED off and blue LED flashing indicates an error. The blue LED will blink a certain number of times, with a 2 second pause, then repeats.
|
|
|
|
|
|
|
|
| Blinks | Meaning |
|
|
|
|
| --- |:--- |
|
2021-04-22 13:54:06 -07:00
|
|
|
| 3 | Sensor failed to heat up within 30 seconds |
|
2020-12-11 18:18:41 -08:00
|
|
|
| 4 | Sensor overheated after entering closed loop mode |
|
|
|
|
| 5 | Sensor unexpectedly cold after entering closed loop mode (bad wiring?) |
|
2021-01-04 14:45:02 -08:00
|
|
|
|
2021-03-13 15:48:25 -08:00
|
|
|
### Bootloader LED Codes
|
|
|
|
|
|
|
|
| Blink pattern | Meaning |
|
|
|
|
| --- |:--- |
|
|
|
|
| alternating slowly | Firmware integrity check failed, please retry firmware upgrade. |
|
|
|
|
| alternating quickly | Waiting for bootloader entry command, only occurs for ~1 second before launching firmware |
|
|
|
|
|
2021-01-04 14:45:02 -08:00
|
|
|
## Source Code
|
|
|
|
|
|
|
|
[The hardware and software source code are hosted here.](https://github.com/mck1117/wideband)
|