In order to configure coolant temperature sensor or intake air sensor you would need to know it's resistance at three temperatures - lowest, highest and somewhere in between. You would also need to know the value of pull-up 'bias' resistor, which together with your sensor would make a voltage divider.
While troubleshooting CLT and IAT, the two most useful commands are `analoginfo` and `tempinfo` - these show you the voltage registered by rusEfi alongside with input pins and resistance processing values.
![analoginfo Output](Images/analoginfo.png)
![tempinfo Output](Images/tempinfo.png)
![CLT Thermistor Settings](Images/thermistor_settings.png)
## Some datapoints
http://rusefi.com/forum/viewtopic.php?f=3&t=864&start=60#p15344
![IAT Thermistor settings](Images/IAT_screen.png)