@ -56,25 +56,6 @@ stop light switch:
ground if not depressed
floating if pressed / depressed
-----------------------------------
[Frankenso analog](https://rusefi.com/wiki/index.php?title=Manual:Hardware_Frankenso_board#Analog_Inputs)
| Analog | ECU pin |MCU pin | pull-up | pull-down | |
|------|------|----|-------|---|---|
| Coolant (stock) | 3Q | PC2 | 2.7K | n/a | |
| Intake Air (stock) | 3P | PC1 | 2.7K | n/a | |
| Vane Air Flow (stock) | 3O | PA0 | n/a | 500K | |
| Narrow Band O2 (stock)| 3N | PC3 | n/a | 500K |
| Wide band oxygen (from middle plug) | W52 | PC3 | n/a | 500K |
| TPS ??? A/T harness only! | 3M | | | |
| Neutral switch | 1V | PA3 | 10K | n/a |
| A/C switch | 1Q | PA6 | 10K | n/a |
| | | | | |
| | | | | |
| MAP (from middle plug) | 2J | PA4 | n/a | 500K |
| Stop Light Switch green wire | 1O rerouted | | | |
| | | | | |
-----------------------------------