Updated HOWTO Miata NB2 on Proteus (markdown)

This commit is contained in:
CrazyStriker 2020-12-22 10:40:28 +01:00
parent 10ef781ed7
commit a6a65156b1
1 changed files with 16 additions and 16 deletions

View File

@ -36,27 +36,27 @@ For the extension connectors the pinnig is the following \:
| 1C| B11| Lowside 14| |
| 1D| B12| Lowside 15| |
| 1E| B23| Lowside 16| |
| 1F| | Ignition 2| |
| 1G| | Ignition 4| |
| 1H| | Ignition 5| |
| 1I| | Ignition 6| |
| 1J| | Ignition 7| |
| 1K| | Ignition 8| |
| 1L| | Ignition 9| |
| 1M| | Ignition 10| |
| 1N| | Ignition 11| |
| 1O| | Ignition 12| |
| 1F| B34| Ignition 2| |
| 1G| B33| Ignition 4| |
| 1H| B32| Ignition 5| |
| 1I| B31| Ignition 6| |
| 1J| B30| Ignition 7| |
| 1K| B29| Ignition 8| |
| 1L| B28| Ignition 9| |
| 1M| B27| Ignition 10| |
| 1N| B26| Ignition 11| |
| 1O| B25| Ignition 12| |
| 1P| | Ground| |
| 1Q| | Ground| |
| 1R| | Ground| |
| 1S| | Ground| |
| 1T| | High Side 2| |
| 1U| | High Side 4| |
| 1V| |12V Protected 2| |
| 1V| A12|12V Protected 2| |
| 1W| | Ground| |
| | | | |
| 2A| | CAN+| |
| 2B| | CAN-| |
| 2A| C17| CAN+| |
| 2B| C16| CAN-| |
| 2C| | VR1+| |
| 2D| | VR1-| |
| 2E| | VR2+| |
@ -71,9 +71,9 @@ For the extension connectors the pinnig is the following \:
| 2N| | Analog Volt 10| |
| 2O| | Analog Volt 11| |
| 2P| | Analog Volt 12| |
| 2Q| | 5V Sensor 1| Used for MAP sensor|
| 2R| | 5V Sensor 2| |
| 2S| | Ground| USED for WBO sensor|
| 2Q| A21| 5V Sensor 1| Used for MAP sensor|
| 2R| A10| 5V Sensor 2| |
| 2S| | Ground| Used for WBO sensor|
| 2T| | ETB1+| |
| 2U| | ETB1-| |
| 2V| | ETB2+| |