## Engine States
|
||||
| State Number | Description | Exit Condition | Next State |
|
||||
|--------------|-------------|----------------|------------|
|
||||
| 0 | **OFF**. Fuel is turned ofd, all relay outputs turned off. | RPM is detected or starter button pin goes to ground | 1-5 based on RPM detected. Will be state 1 if starter pin is grounded |
|
||||
| 0 | **OFF**. Fuel is turned off, all relay outputs turned off. | RPM is detected or starter button pin goes to ground | 1-5 based on RPM detected. Will be state 1 if starter pin is grounded |
|
||||
| 1 | **PRE-START**. Starter is turned on but fuel and ignition are off. Will remain in this mode until RPM reaches defined level or times out | RPM exceeds X1 or time with starter on exceeds timeout value | 2 (or 0 if timed out) |
|
||||
| 2 | **START**. Fuel and ignition are turned on | RPM exceeds X2 or time with starter on exceeds timeout value | 3 (or 0 if timed out) |
|
||||