# Battery Monitoring
|
|
|
|
Cleanflight has battery monitoring capability. Battery voltage of the main battery can be measured by the system and used
|
|
to trigger a low-battery warning buzzer, on-board status LED flashing and LED strip patterns.
|
|
|
|
Low battery warnings can:
|
|
|
|
* help to ensure that you have time to safely land the aircraft.
|
|
* help maintain the life and safety of your LiPo/LiFe batteries which should not be discharged below manufactures recommendations.
|
|
|
|
Minimum and maximum cell voltages can be set, these voltages are used to detect the amount of cells you are using.
|
|
|
|
Per-cell monitoring is not supported.
|
|
|
|
## Supported targets
|
|
|
|
All targets support battery voltage monitoring unless status.
|
|
|
|
## Connections
|
|
|
|
When dealing with batteries ALWAYS CHECK POLARITY!
|
|
|
|
Measure expected voltages first and then connect to flight controller, connecting to the flight controller with
|
|
incorrect voltage or reversed polarity will likely fry your flight controller.
|
|
|
|
### Naze32
|
|
|
|
The Naze32 has an on-board battery divider circuit, connect your main battery to the VBAT connector.
|
|
|
|
### CC3D
|
|
|
|
The CC3D has no battery divider, create one that gives you a 3.3v MAXIMUM output when your battery is
|
|
fully charged and connect the output from it to S5_IN/PA0/RC5.
|
|
|
|
S5_IN/PA0/RC5 is Pin 7 on the 8 pin connector, second to last pin, opposite end from the GND/+5/PPM signal input.
|
|
|
|
Note: When battery monitoring is enabled on the CC3D RC5 can no-longer be used for PWM input.
|
|
|
|
## Configuration
|
|
|
|
Enable the `VBAT` feature.
|
|
|
|
Configure min/max cell voltages using the following CLI commands:
|
|
|
|
`vbat_scale` - adjust this to match battery voltage to reported value.
|
|
|
|
`vbat_max_cell_voltage` - maximum voltage per cell, used for auto-detecting battery voltage in 0.1V units, i.e. 43 = 4.3V
|
|
|
|
`vbat_min_cell_voltage` - minimum voltage per cell, this triggers battery out alarms, in 0.1V units, i.e. 33 = 3.3V
|
|
|
|
e.g.
|
|
|
|
```
|
|
set vbat_scale = 110
|
|
set vbat_max_cell_voltage = 43
|
|
set vbat_min_cell_voltage = 33
|
|
```
|