2023-01-06 17:10:33 -08:00
# microRusEFI QC Procedure
2021-04-29 09:18:47 -07:00
We use special QC firmware
2023-01-02 11:22:23 -08:00
2022-04-09 19:23:37 -07:00
1) Download [MRE F4 Hardware QC Special Build 2020.11.27 ](https://github.com/rusefi/rusefi/releases/download/2020.11.27_release/rusefi_bundle_mre_f4_hardware_QC_special_build.zip ) or better [2022.04.09_release QC ](https://github.com/rusefi/rusefi/releases/download/2022.04.09_release/rusefi_bundle_mre_f4_hardware_QC_special_build.zip )
2021-04-29 09:18:47 -07:00
1) using Manual DFU mode flash abovementioned 2020 Black Friday rusefi_bundle_mre_f4_hardware_QC_special_build.zip
1) disconnect microRusEFI from USB, plug microRusEFI into special test fixture LED board, power special test fixture LED board with +12v
1) observe lack of smoke
1) observe expected LED flashing sequence
2021-04-29 09:21:30 -07:00
1) observe expected MRE red LED 'fatal' state (would be solid in case of failed analog AT test)
2021-04-29 09:20:40 -07:00
This procedure tests
2023-01-02 11:22:23 -08:00
2021-04-29 09:20:40 -07:00
1) 12v to 5v to 3v power dance
1) low and high side outputs
1) four AT inputs by asserting expected voltage
1) with manual button cam sensor could be tested - it's expected to see red CAM led respond to manual button
1) with manual button crank sensor could be tested if configured as Hall - it's expected to see red crank led respond to manual button
This procedure does NOT test
2021-04-29 09:24:45 -07:00
2023-01-02 11:22:23 -08:00
1) VR input
2021-04-29 09:24:45 -07:00
2022-01-24 14:48:22 -08:00
After the text please flash latest normal release [MRE F4 Firmware bundle ](https://github.com/rusefi/rusefi/releases/latest/download/rusefi_bundle_mre_f4.zip )
2021-07-30 20:55:49 -07:00
Attach an orange QC sticker to the part of the connector visible outside of the case.