Boost Control
General Purpose PWM 1
Pin: This implementation produces one pulse per engine cycle. See also dizzySparkOutputPin.
On above duty(%): In on-off mode, turn the output on when the table value is above this duty.
Off below duty(%): In on-off mode, turn the output off when the table value is below this duty.
Duty if error(%): If an error (with a sensor, etc) is detected, this value is used instead of reading from the table. This should be a safe value for whatever hardware is connected to prevent damage.
Load Axis: Selects the load axis to use for the table.
General Purpose PWM 2
Pin: This implementation produces one pulse per engine cycle. See also dizzySparkOutputPin.
On above duty(%): In on-off mode, turn the output on when the table value is above this duty.
Off below duty(%): In on-off mode, turn the output off when the table value is below this duty.
Duty if error(%): If an error (with a sensor, etc) is detected, this value is used instead of reading from the table. This should be a safe value for whatever hardware is connected to prevent damage.
Load Axis: Selects the load axis to use for the table.
General Purpose PWM 3
Pin: This implementation produces one pulse per engine cycle. See also dizzySparkOutputPin.
On above duty(%): In on-off mode, turn the output on when the table value is above this duty.
Off below duty(%): In on-off mode, turn the output off when the table value is below this duty.
Duty if error(%): If an error (with a sensor, etc) is detected, this value is used instead of reading from the table. This should be a safe value for whatever hardware is connected to prevent damage.
Load Axis: Selects the load axis to use for the table.
General Purpose PWM 4
Pin: This implementation produces one pulse per engine cycle. See also dizzySparkOutputPin.
On above duty(%): In on-off mode, turn the output on when the table value is above this duty.
Off below duty(%): In on-off mode, turn the output off when the table value is below this duty.
Duty if error(%): If an error (with a sensor, etc) is detected, this value is used instead of reading from the table. This should be a safe value for whatever hardware is connected to prevent damage.
Load Axis: Selects the load axis to use for the table.
FSIO inputs
Aux PID
Detailed status in console: Print details into rusEfi console
FSIO outputs
FSIO Table #1
FSIO Table #2
FSIO Table #3
FSIO Table #4
FSIO Formulas
use FSIO #16 for timing adjustment: See fsioTimingAdjustment
FSIO Curve #1
FSIO Curve #2
FSIO Curve #3
FSIO Curve #4