HOWTO test brand new ECU design which was never fabricated before

If dealing with a brand new never before tested hardware design it's recommended to gradually add wires one by one.

Prerequisites for each testing session

  1. Charge battery
  2. Disconnect battery charger
  3. Warm up car on stock ECU
  4. Charge laptop battery
  5. Disconnect laptop from wall charger.

Minimal ECU Power Test

  1. Write down battery voltage measured at the battery, with charger and all ECUs physically disconnected.
  2. Hook up Power GND
  3. Hook up ECU power source
  4. Test & Report, with USB physically disconnected: ECU status LED starts to blink if powered up, ECU status and all LED go off when powered off.
  5. Test & Report, with USB physically disconnected: Attempt cranking. If equipped with on-board persistent storage, upload & link log to report.
  6. Connect ECU to laptop via serial, report type of serial.