# WBO Overview
|
|
|
|
[Do-i-need-wideband-oxygen-sensor](https://github.com/rusefi/rusefi/wiki/do-i-need-wideband-oxygen-sensor)
|
|
|
|
## External WBO
|
|
|
|
* External controller with analog output, like then AEM 30-4110 and similar products.
|
|
* External controller with CAN interface, like the AEM X-Series wideband controller/gauge.
|
|
|
|
## rusEFI Wide band oxygen
|
|
|
|
rusEFI has two probably working implementations for Bosch wideband oxygen control:
|
|
|
|
* We have cj125 integration
|
|
* We like [https://github.com/mck1117/wideband](https://github.com/mck1117/wideband) even more. See [the forum thread](https://rusefi.com/forum/viewtopic.php?f=4&t=1856)
|
|
|
|
## rusEFI wideband module
|
|
|
|
See [rusEFI-Wideband-Controller](rusEFI-Wideband-Controller)
|
|
|
|
See [Hellen-WBO](Hellen-WBO)
|
|
|
|
TODO: document it better
|
|
|
|
## cj125 troubleshooting
|
|
|
|
We have a few rusEFI console commands relevant for cj125
|
|
|
|
``cj125_info``
|
|
|
|
``cj125_restart``
|
|
|
|
``cj125_calibrate``
|
|
|
|
![x](Overview/wbo/cj125_heating_4_9.png)
|
|
|
|
AndreiKA says Prometheus works
|
|
|
|
Matthew says 0.3 SOIC-24 boards works
|
|
|
|
Wideband controller based on Bosch CJ125 chip
|
|
|
|
green is vUr, temperature feedback
|
|
|
|
red is duty cycle
|
|
|
|
yellow is vUa, the lambda current measurement
|
|
|
|
white is converted AFR
|
|
|
|
fully operating in <30 seconds
|
|
|
|
in to closed loop in ~18 seconds
|
|
|
|
P=30
|
|
|
|
I=5
|
|
|
|
D=0.3
|
|
|
|
though you could probably use D=0 since the system is already damped so hard
|
|
|
|
50Hz
|
|
|
|
[Older SOIC-24 board - double sided assembly](https://github.com/rusefi/hw_modular/tree/master/cj125_Module)
|
|
|
|
[Newer LQFP-32 board - single side assembly](https://github.com/rusefi/rusefi/tree/master/hardware/CJ125_board)
|
|
|
|
## Naming Convention
|
|
|
|
IP=Pump Current
|
|
|
|
VS/IP=VM=common virtual ground for VS and IP
|
|
|
|
R Trim=Calibration resistor
|
|
|
|
H+ Constant +12v
|
|
|
|
H- Heater control, low-side
|
|
|
|
UN = Vs = sensor voltage output
|
|
|
|
4.9 pinout courtesy of [https://www.wbo2.com/cable/lsuconns.htm](https://www.wbo2.com/cable/lsuconns.htm)
|
|
|
|
![x](FAQ/LSU-4-9-17025hcon.gif)
|
|
|
|
![x](FAQ/LSU_42_LSU_49_Plug_Comparsion.jpg)
|
|
|
|
With SOIC-24 rusEFI module W1=W10=0R means LSU 4.2
|
|
|
|
With SOIC-24 rusEFI module W1=W10=Do not populate means LSU 4.9
|
|
|
|
**Q: Any troubleshooting hints when things do not work?**
|
|
|
|
A: VM wire between CJ125 and sensor is virtual ground, should measure 2.5v when sensor is connected and when sensor is disconnected.
|
|
|
|
## Part Numbers
|
|
|
|
### Connector Shells
|
|
|
|
| Connector | Part Number |
|
|
| :--------------: | :---------: |
|
|
| Female (harness) | 1928404669 |
|
|
| Male (sensor) | 1928405111 |
|
|
|
|
Male connector is only needed when building extension harnesses. The connector on the sensor contains a laser-trimmed calibration resistor and should not be removed.
|
|
|
|
### Female Terminals for Harness Side
|
|
|
|
| Wire Size | Plating | Strip | Loose |
|
|
| :-------: | :-----: | :---------: | :---------: |
|
|
| 24-22 AWG | Tin | 1564324-1 | 1564325-1 |
|
|
| 24-22 AWG | Gold | 1564324-2 | 1564325-2 |
|
|
| 20-18 AWG | Tin | 1241380-1 | 1241381-1 |
|
|
| 20-18 AWG | Gold | 1241380-2 | 1241381-2 |
|
|
| 16 AWG | Tin | 1418884-1 | 1418885-1 |
|
|
| 16 AWG | Gold | unavailable | unavailable |
|
|
|
|
Part numbers provided by and available for purchase at corsa-technic.com individually or as a kit. <https://www.corsa-technic.com/item.php?item_id=1296>
|
|
|
|
## ADV
|
|
|
|
1J0973705 8R0906262E
|