1.5 KiB
1.5 KiB
NOTE: This is currently under development. This page might be wrong or change quickly.
Pinout
Pin Number | Function | Notes |
---|---|---|
1 | Ground | Connect to chassis ground |
2 | LSU Ip | Connect to sensor pin 1 |
3 | LSU Heater - | Connect to sensor pin 3 |
4 | LSU Heater + | Connect to sensor pin 4 |
5 | No connection | |
6 | 12v Supply | Connect to fuel pump supply or independent relay controlled by ECU |
7 | No connection | |
8 | LSU Vm | Connect to sensor pin 2 |
9 | LSU Rtrim | Connect to sensor pin 5 |
10 | LSU Un | Connect to sensor pin 6 |
11 | CAN H | CAN bus high |
12 | CAN L | CAN bus low |
LED decoding
Blue LED | Green LED | Meaning |
---|---|---|
off | fast flash | sensor warming up |
off | slow flash | Sensor hot, operating normally |
flashing | off | See error code table below |
alternating | alternating | Bootloader |
Firmware Update
coming soon...
Error Codes
Green LED off and blue LED flashing indicates an error. The blue LED will blink a certain number of times, with a 2 second pause, then repeats.
Blinks | Meaning |
---|---|
3 | Sensor failed to heat up within 15 seconds |
4 | Sensor overheated after entering closed loop mode |
5 | Sensor unexpectedly cold after entering closed loop mode (bad wiring?) |